INSTALLATION |
TECHNICAL SPECIFICATIONS – UNDER- WATER COOLER
| Model / Make |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
| Input |
|
|
|
| 50/60 Hz | 1 Phase | |||
|
|
|
|
|
|
|
|
|
| |
| Rated Current Draw | 60 Hz |
|
| 50 Hz | |||||
|
|
|
|
|
|
|
|
| ||
| Operating Pressure |
|
| 60 psig (413 kPa) (4.1 bar) | ||||||
|
|
|
|
|
|
|
|
|
|
|
| Pump Hydraulic |
|
|
|
|
|
|
|
| |
| Rating | No Flow | Discharge Pressure (gage) |
|
|
| ||||
|
|
|
|
| (Relief Valve Setting) |
| 60 PSIG (414 kPa) (4.14 bar) Max. | |||
|
|
|
|
|
|
|
|
| ||
|
|
| No Pressure | Flow Rate |
|
| 1.66 gal/min (6.28 liter/min) Max. | |||
|
|
|
|
|
|
|
|
|
|
|
| Pump Hydraulic Rating |
|
|
|
|
|
| |||
| (Typical Operation) | Discharge Pressure (gage) |
| |||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
| Flow Rate |
|
| |||
|
|
|
|
|
|
|
| |||
| Reservoir Capacity |
|
| 2.0 Gallons (7.6 Liters) | ||||||
|
|
|
|
|
|
|
| |||
|
|
|
|
| For Use Above Freezing: Clean tap, distilled, or | |||||
|
|
|
|
| For Use Below Freezing: 50% water and 50% pure ethylene glycol mixture. | |||||
| Recommended Coolant | DO NOT USE: Automotive | ||||||||
|
|
|
|
| stoppers. These coolants will damage the pump and block the small internal | |||||
|
|
|
|
| passageways of the heat exchanger, affecting cooling performance. To | |||||
|
|
|
|
| acquire the proper coolant contact a local welding distributor. | |||||
|
|
|
|
| DO NOT USE: | |||||
|
|
|
|
| contain | |||||
|
|
|
|
| cooler. Once added to the cooler, these substances are virtually impossible to | |||||
|
|
|
|
| purge from the water lines and heat exchanger. | |||||
|
|
|
|
|
|
|
| |||
Weight |
| Shipping |
|
| 252 lbs. (114 kg) |
| ||||
|
|
| Reservoir Full (Water) |
| 267 lbs. (121 kg) |
| ||||
|
|
|
|
|
|
|
|
| ||
| Dimensions |
| Length |
|
| 41 in (1041 mm) |
| |||
|
|
| Width |
|
| 27 in (686 mm) |
| |||
|
|
| Height (Top Face) | 21 in ( 533mm ) |
| |||||
|
|
| Height (TIG Interface) | 19 in (483 mm) |
|