Lincoln Electric IM723-A manual Installation

Page 8

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS – UNDER- WATER COOLER

 

Model / Make

 

 

 

 

Under-Cooler Cart

K1828-1

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

 

100-120 VAC

50/60 Hz

1 Phase

 

 

 

 

 

 

 

 

 

 

 

Rated Current Draw

60 Hz (2.8-3.5 Amps)

 

 

50 Hz (3.5-5.3 Amps)

 

 

 

 

 

 

 

 

 

 

Operating Pressure

 

 

60 psig (413 kPa) (4.1 bar)

 

 

 

 

 

 

 

 

 

 

 

 

Pump Hydraulic

 

 

 

 

 

 

 

 

 

Rating

No Flow

Discharge Pressure (gage)

 

 

 

 

 

 

 

 

(Relief Valve Setting)

 

60 PSIG (414 kPa) (4.14 bar) Max.

 

 

 

 

 

 

 

 

 

 

 

 

No Pressure

Flow Rate

 

 

1.66 gal/min (6.28 liter/min) Max.

 

 

 

 

 

 

 

 

 

 

 

 

Pump Hydraulic Rating

 

 

 

 

 

 

 

(Typical Operation)

Discharge Pressure (gage)

 

53-57 PSIG (365-393 kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flow Rate

 

 

.45-.60 gal/min (1.7-2.3 liter/min)

 

 

 

 

 

 

 

 

 

Reservoir Capacity

 

 

2.0 Gallons (7.6 Liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

For Use Above Freezing: Clean tap, distilled, or de-ionized water

 

 

 

 

 

For Use Below Freezing: 50% water and 50% pure ethylene glycol mixture.

 

Recommended Coolant

DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak

 

 

 

 

 

stoppers. These coolants will damage the pump and block the small internal

 

 

 

 

 

passageways of the heat exchanger, affecting cooling performance. To

 

 

 

 

 

acquire the proper coolant contact a local welding distributor.

 

 

 

 

 

DO NOT USE: Pre-packaged welding industry coolants. These coolants may

 

 

 

 

 

contain oil-based substances, which attack the plastic components of the

 

 

 

 

 

cooler. Once added to the cooler, these substances are virtually impossible to

 

 

 

 

 

purge from the water lines and heat exchanger.

 

 

 

 

 

 

 

 

Weight

 

Shipping

 

 

252 lbs. (114 kg)

 

 

 

 

Reservoir Full (Water)

 

267 lbs. (121 kg)

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

Length

 

 

41 in (1041 mm)

 

 

 

 

Width

 

 

27 in (686 mm)

 

 

 

 

Height (Top Face)

21 in ( 533mm )

 

 

 

 

Height (TIG Interface)

19 in (483 mm)

 

UNDER-COOLER CART

Image 8
Contents UNDER-COOLER Cart Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Safety Precautions HOT Coolant can Burn SkinTAT I N G FA N B L a D E S a R E Hazardous UnpackingCoolant Connections Figure A-1Assembly of Precision TIG Input Power ConnectionSafety Precautions AssemblyFastener Quick Reference Connection of TIG TorchesOperation General DescriptionRecommended Processes Recommended EquipmentTurning the System on Cooling EfficiencyMaintenance Reservoir Coolant Level Coolant Treatment RecommendationProcedure Pump Inlet FilterAdditional Service Notes Service the pump’s inlet strainerTroubleshooting HOW to USE Troubleshooting GuideContact your local Lincoln Authorized Field Service Facility Wiring Diagram UNDER-COOLER CartK1828-1 Under-Cooler Cart Water Cooler Flow Diagram Dimension Print UNDER-COOLER Cart UNDER-COOLER Cart UNDER-COOLER Cart Precaucion Warnung