Lincoln Electric E500 specifications Troubleshooting

Page 15

 

D-5

 

TROUBLESHOOTING

 

D-5

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed througout this manual

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE CAUSE

 

RECOMMENDED

 

 

(SYMPTOMS)

 

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

 

 

 

 

 

 

 

H. Machine trips off when under no

1. Power bridge rectifier may have

1.

Refer to Power Hybrid Bridge

 

load or makes excessive noise

 

a shorted diode or SCR.

 

Checking Procedure. See

 

like it is loaded.

 

 

 

Troubleshooting Procedures –

 

 

 

 

 

 

Checking Snubber Circuit and

 

 

 

 

 

 

Power Rectifier Bridge Assembly.

 

 

 

2.

Short in the transformer.

2.

Repair.

 

 

 

3.

Fan hitting vertical baffle.

3.

Clear the fan.

 

 

 

 

 

 

 

I. Variable or sluggish welding arc.

1. Poor work or electrode cable

1.

Check and clean cable connec-

 

 

 

 

connection.

 

tions.

 

 

 

2.

Current too low.

2.

Check recommended currents

 

 

 

 

 

 

for rod type and size.

 

 

 

3.

Welding leads too small.

3.

See Troubleshooting Procedures

 

 

 

 

 

 

– Fault Protection Operation.

 

 

 

4.

Open SCR or diode in power

4.

Check per Power Hybrid Bridge

 

 

 

 

rectifier bridge.

 

Procedures. See

 

 

 

 

 

 

Troubleshooting Procedures –

 

 

 

 

 

 

Checking Snubber Circuit.

 

 

 

5.

Control circuit problems.

5.

See Troubleshooting

 

 

 

 

 

 

Procedures.

 

 

 

 

 

 

 

J. Welder will not shut off.

1. Input contactor contacts frozen.

1.

Replace input contactor.

 

 

 

 

 

 

K. Current control on machine not

1. Current control switch in wrong

1.

Place switch in “machine” posi-

 

functioning.

 

position.

 

tion.

 

 

 

2.

Current control switch defective.

2.

See Troubleshooting Procedures

 

 

 

 

 

 

– Toggle Switch Check.

 

 

 

3.

Current control potentiometer

3.

See Troubleshooting Procedures

 

 

 

 

defective.

 

– Checking Current Control

 

 

 

 

 

 

Rheostat.

 

 

 

4.

Lead or connection in control

4. Repair or connect.

 

 

 

 

circuit open.

 

 

 

 

 

 

5.

Defective control or circuit

5.

See Troubleshooting Procedure

 

 

 

 

boards.

 

– Power Silicon Controlled

 

 

 

 

 

 

Rectifier.

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

E500

Image 15 Contents
RED-D-ARC E500 California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Output Studs InstallationInput Wiring Output ConnectionsOptional Equipment OperationTesting the Gfci Receptacle MaintenanceGeneral Maintenance Power Rectifier ReplacementHOW to USE Troubleshooting Guide TroubleshootingRecommended Symptoms Course of ActionTroubleshooting Troubleshooting Troubleshooting Gfci OCV is Rated OCV but Checking Snubber Circuit Procedure for Replacing P.C. BoardOutput Voltage Overload ProtectionPower Silicon Controlled Rectifier Test Toggle Switch CheckRemote Control Check Checking Power Rectifier Bridge AssemblyBattery Test DiagramSCR Test E500 Wiring Diagram 230/460/575 Wiring Diagram Code 10649 onlyE500 Wiring Diagram 230/460/575 Wiring Diagram Code 11042 & UPDiagrams E500 E500 Precaucion Aviso DE