Lincoln Electric 11006 Installation, NON-STANDARD Safety Information, Input Connections, Location

Page 11

A-1

INSTALLATION

A-1

NON-STANDARD SAFETY INFORMATION

WARNING

ELECTRIC SHOCK can kill.

Turn off power at the power source disconnect switch before working inside the equipment.

------------------------------------------------------------------------

WARNING

INPUT CONNECTIONS

Only a qualified electrician should connect the Spreadarc. Installation should be made in accor- dance with the appropriate National Electrical

Code, all local codes and the information in this manual.

------------------------------------------------------------------------

LOCATION

The Spreadarc will operate in harsh environments. Even so, it is important that simple preventative mea- sures are followed in order to assure long life and reli- able operation.

The Spreadarc must be located where there is free circulation of clean air such that air movement in the back, sides and bottom will not be restricted.

Dirt and dust that can be drawn into the Spreadarc should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown.

MOUNTING

(See Figure A-1)

1.The Spreadarc can be mounted on a K325 travel carriage or on a stationary head mount in which case the work piece must be moved. When more than one wire reel is used, the K325HC heavy duty travel carriage is recommended. In many applica- tions it may be desirable to use the K29 vertical lift adjuster.

2.Remove the hex nut Item 1 and the support pin Item 2 from the Spreadarc mounting block Item 3. With the draw bolt Item 4 properly in place, mount the Spreadarc to the head support or vertical lift Item 5. Maintain support until the support pin Item 2 is inserted into the mounting block Item 3, and install hex nut Item 1 and draw bolt Item 4. Rotate the Spreadarc until it is perpendicular to the travel carriage beam and tighten hex nut Item 1. Make certain that the travel carriage beam or stationary mount is properly squared up. The Spreadarc must be level in the horizontal plane within ±2°.

FIGURE A-1

5

2

4 1 3

SPREADARC

Image 11
Contents Spreadarc Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionPrécautions DE Sûreté Thank You Table of Contents Recommended Processes and Equipment Design FeaturesGeneral Information Product DescriptionAdvanced Package Common Equipment PackagesBasic Package Voltage Input Amperes Technical Specifications Spreadarc K279-1Location InstallationNON-STANDARD Safety Information Input ConnectionsFigure A-2 High Frequency ProtectionConnection to 115Vac direct Connection DiagramConnection to 42Vac Power Source Connection to 115Vac Power SourceCase Front Control Description OperationUser Interface Controls Setting Oscillation SpeedCommon Welding Procedures To remove the tracks MaintenancePeriodic Maintenance Tracks and BearingsControl BOX Calibration SpecificationWiring Diagrams Dimension Print Precaucion Warnung