D-2

MAINTENANCE

D-2

5.With the control box and carriage out of the way, access to the track fasteners Item 12 can be gained.

6.Inspect the four "V" bearings on the carriage to veri- fy that they rotate freely and are not excessively worn.

7.Note: Do not loosen the hex nuts holding the gear motor in place – the gear motor has been factory set to give proper clearance between the rack and pinion

8.Remove the eight hex head screws Item 12 holding the top and bottom tracks in place and remove the tracks.

9.Install new tracks, or switch the tracks, on the track support Item 13 ensuring that the tracks are seated firmly on the edges of the track support.

10.Reassemble all parts except for the top and bot- tom track shields and proximity sensor bracket.

11.To adjust the eccentric nuts on the bottom "V" bearings, tighten the 1/2-13 screws until snug.

12.Rotate the eccentric nuts to bring the bottom bear- ings snug against the track.

13.While holding the eccentric nuts securely, tighten the 1/2-13 screws.

14.Verify proper pressure by turning outer race of bottom bearings by hand. They must slip on track, but there must be no vertical play in the carriage assembly. Readjust eccentric nuts, if necessary.

15.Lubricate tracks and bearings and install top and bottom track shields and proximity sensor bracket.

CONTROL BOX

Every six months inspect the control box. If needed, blow dirt out using low pressure air. Replace screw holding door closed.

CALIBRATION SPECIFICATION

All calibration is factory set on the Spreadarc.

SPREADARC

Image 18
Contents Safety Depends on You SpreadarcSafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Thank You Table of Contents Product Description Design FeaturesGeneral Information Recommended Processes and EquipmentCommon Equipment Packages Basic PackageAdvanced Package Technical Specifications Spreadarc K279-1 Voltage Input AmperesInput Connections InstallationNON-STANDARD Safety Information LocationHigh Frequency Protection Figure A-2Connection to 115Vac Power Source Connection DiagramConnection to 42Vac Power Source Connection to 115Vac directOperation Case Front Control DescriptionSetting Oscillation Speed User Interface ControlsCommon Welding Procedures Tracks and Bearings MaintenancePeriodic Maintenance To remove the tracksCalibration Specification Control BOXWiring Diagrams Dimension Print Precaucion Warnung