Friedrich SP05A10 service manual When the compressor is not operated

Page 18

Troubleshooting

5-2-4 When the compressor is not operated

1)Check points

(1)Is the voltage of the power source normal ? (the rating voltage ±10% range. )

(2)Is the desired temperature lower than the indoor temperature in the “COOL” mode? (Compressor stopped)

(3)Is the starting condenser in good contact?

(4)Is the electric wire in good contact ? (CN71, RY71)

(5)Is the output voltage of the IC01(KA7812) and IC02(KA7805) normal ?

Turn off the power, and then turn it on again five

seconds later.

N

Dose the Buzzer sound, when the power on?

Y

Check whether the "COOLING ICON" LED lamp is on

N

and the operation starts when pressing the on/off

 

 

button of the remocon.

 

Go to the clause "No power".

Go to the clause "when he remocon does not operate".

Y

Check whether the compressor is activated in three

Y

minutes after turning on the power with the "CoolING

 

ICON" LED lamp being switched on when selecting the

 

 

cool mode of the remocon.

 

 

 

 

Normal operation.

N

Is the IC03 output normal?

- When the compressor is on, IC03 No. 13 pin Low.

Y

Does the relay(RY71) operate normally?

- When the compressor is ON, the RY71 should operate.

Y

Is the compressor normal?

Y

Replace the compressor.

N

N

N

Check the IC03 for short and cold soldering.

Replace the IC03.

Check the relay coil resistance. (resistance : About 150±20)

Replace the relay.

Check the operation of the O.L.P, and replace it if necessary.

Check the compressor

resistance.(0: short, ∞Ω : open)

FRIEDRICH AIR CONDITIONING CO.

5-5

Image 18
Contents Room AIR Conditioner Precautions Avoid Dangerous ContactEER Memo Dimensions Installation and Operating Instructions InstallationSelecting Area for Installation Energy saver operation mode Cooling operation modeFan operation mode Function DescriptionSleep operation mode Dry operation modeLED display indication in case of error detection Memo Disassembly and Reassembly Compressor Replacement Flow ChartChecking the oil Oil qualityReplacing and refilling the refrigerant oil Disassembly and Reassembly ProcedureSP05A10 Ass’y GrillePart Name Procedures Remarks Troubleshooting Basic Checkpoints for TroubleshootingTroubleshooting by Symptom No powerWhen the Touch Key pad and Led Display TroubleshootingWhen the remocon is not operated When the compressor is not operated When the fan motor does not operated LOWExploded View and Parts List Main unitExploded View and Parts List Part List Micom Control Diagram Block DiagramRefrigerating Cycle Block Diagram Basic StructureMicom pin assignment KS88C4716 RemoconPCB Digram PCB Parts Wiring Diagram Schematic Diagrams Friedrich AIR Conditioning CO

SP05A10 specifications

The Friedrich SP05A10 is an advanced air conditioning unit known for its innovative design, efficient cooling capabilities, and user-friendly features. This model is particularly noted for its energy efficiency, making it a suitable choice for both residential and commercial spaces.

One of the main features of the Friedrich SP05A10 is its energy-efficient operation, which is reflected in its SEER (Seasonal Energy Efficiency Ratio) rating. This unit often exceeds the industry standards, resulting in lower electricity bills and a reduced carbon footprint. The inverter technology employed in this model allows the compressor to adjust its speed according to the cooling demands, ensuring optimal energy consumption without sacrificing comfort.

The SP05A10 also boasts a robust cooling capacity. It provides powerful cooling without being excessively noisy, thanks to its well-engineered sound-dampening features. The Quiet Master technology minimizes operational noise levels, allowing users to enjoy a peaceful environment. This makes it especially appealing for bedrooms, offices, and other noise-sensitive areas.

Ease of use is another hallmark of the Friedrich SP05A10. The unit is equipped with a user-friendly digital thermostat and an intuitive remote control, giving users full control over their comfort settings. The programmable timer feature allows users to set the air conditioner to operate at specific times, promoting convenience and energy savings.

Durability and build quality are also crucial characteristics of the SP05A10. Constructed with high-quality materials, it offers a long-lasting performance that withstands the test of time. Additionally, the model features washable and reusable filters that improve air quality while reducing maintenance costs.

Friedrich leans heavily into innovation, and the SP05A10 is no exception. It features smart technology that allows users to control the air conditioning unit remotely through a smartphone app. This connectivity provides endless possibilities, including monitoring energy usage and adjusting settings from anywhere.

In summary, the Friedrich SP05A10 air conditioning unit excels in energy efficiency, cooling capacity, and user-friendliness. Its combination of advanced technologies, quiet operation, and robust durability makes it an excellent choice for those seeking reliable indoor climate control. Whether for home or office use, the SP05A10 promises comfort and satisfaction for years to come.