Friedrich SP05A10 service manual Function Description, Cooling operation mode, Fan operation mode

Page 7

3-2 Function Description

3-2-1 Cooling operation mode

The compressor is turned on and off according to the ambient temperature and set temperature.

1)Compressor on and off control

Compressor on and off control according to the ambient temperature

*The compressor is turned off when "ambient temperature = set temperature

*The compressor is turned on when "ambient temperature = set temperature +1˚C"

2)Default value after power reset set temperature = 75˚F

Fan speed = High

3) Set temperature indicating (setting) range : 1˚F interval from 64˚F to 86˚F.

3-2-2 Fan operation mode

1)If "Fan operation mode" signal is received from remocon or panel.

the compressor is immediately turned off and only fan motor is operated at set blowing speed.

it changes such as "High Med Low High"( if Fan speed is selected).

2)The initial Fan motor speed is set to "High".

3)The set temperature can not be indicated and set.

3-2-3 Energy saver operation mode

*If the compressor turn off at the cooling operation, the fan motor turn off after operation during the fixation time only, and operation that energy saver by turn off the fixation time only, and operation that energy saver by turn off the motor continuously before the condition of the compressor on.

*The fan motor is not operated at flow wind operation.

*Energy saver operation specification at the cooling operation.

1)Fan motor control in compressor on : operate with setting wind speed

2)Fan motor control in compressor off : After compressor off, the fan motor is operated breeze for 2 minutes and then it turn off.

3)After the fan motor off, the compressor and fan motor is operated normally when the compressor on.

3-2

FRIEDRICH AIR CONDITIONING CO.

Image 7
Contents Room AIR Conditioner Avoid Dangerous Contact PrecautionsEER Memo Dimensions Installation Installation and Operating InstructionsSelecting Area for Installation Function Description Cooling operation modeFan operation mode Energy saver operation modeDry operation mode Sleep operation modeLED display indication in case of error detection Memo Compressor Replacement Flow Chart Disassembly and ReassemblyOil quality Checking the oilReplacing and refilling the refrigerant oil Ass’y Grille Disassembly and Reassembly ProcedureSP05A10Part Name Procedures Remarks Basic Checkpoints for Troubleshooting TroubleshootingNo power Troubleshooting by SymptomTroubleshooting When the Touch Key pad and Led DisplayWhen the remocon is not operated When the compressor is not operated LOW When the fan motor does not operatedMain unit Exploded View and Parts ListExploded View and Parts List Part List Basic Structure Block DiagramRefrigerating Cycle Block Diagram Micom Control DiagramRemocon Micom pin assignment KS88C4716PCB Digram PCB Parts Wiring Diagram Schematic Diagrams Friedrich AIR Conditioning CO

SP05A10 specifications

The Friedrich SP05A10 is an advanced air conditioning unit known for its innovative design, efficient cooling capabilities, and user-friendly features. This model is particularly noted for its energy efficiency, making it a suitable choice for both residential and commercial spaces.

One of the main features of the Friedrich SP05A10 is its energy-efficient operation, which is reflected in its SEER (Seasonal Energy Efficiency Ratio) rating. This unit often exceeds the industry standards, resulting in lower electricity bills and a reduced carbon footprint. The inverter technology employed in this model allows the compressor to adjust its speed according to the cooling demands, ensuring optimal energy consumption without sacrificing comfort.

The SP05A10 also boasts a robust cooling capacity. It provides powerful cooling without being excessively noisy, thanks to its well-engineered sound-dampening features. The Quiet Master technology minimizes operational noise levels, allowing users to enjoy a peaceful environment. This makes it especially appealing for bedrooms, offices, and other noise-sensitive areas.

Ease of use is another hallmark of the Friedrich SP05A10. The unit is equipped with a user-friendly digital thermostat and an intuitive remote control, giving users full control over their comfort settings. The programmable timer feature allows users to set the air conditioner to operate at specific times, promoting convenience and energy savings.

Durability and build quality are also crucial characteristics of the SP05A10. Constructed with high-quality materials, it offers a long-lasting performance that withstands the test of time. Additionally, the model features washable and reusable filters that improve air quality while reducing maintenance costs.

Friedrich leans heavily into innovation, and the SP05A10 is no exception. It features smart technology that allows users to control the air conditioning unit remotely through a smartphone app. This connectivity provides endless possibilities, including monitoring energy usage and adjusting settings from anywhere.

In summary, the Friedrich SP05A10 air conditioning unit excels in energy efficiency, cooling capacity, and user-friendliness. Its combination of advanced technologies, quiet operation, and robust durability makes it an excellent choice for those seeking reliable indoor climate control. Whether for home or office use, the SP05A10 promises comfort and satisfaction for years to come.