Friedrich US08B10A, US14B30A, US12B10A, US10B30A, US10B10A manual Contents, Preface

Page 2

CONTENTS

1. PREFACE

 

1.1 SAFETY PRECAUTIONS

2

1.2 INSULATION RESISTANCE TEST

2

1.3 SPECIFICATIONS

3

1.4 FEATURES

5

1.5 CONTROL LOCATIONS

5

2. DISASSEMBLY INSTRUCTIONS

 

2.1 MECHANICAL PARTS

6

2.1.1 FRONT GRILLE

6

2.1.2 CABINET

6

2.1.3 CONTROL BOX

6

2.2 AIR HANDLING PARTS

7

2.2.1 ORIFICE, HEATER ASSY AND TURBO FAN

7

2.2.2 FAN

7

2.2.3 SHROUD

8

2.3 ELECTRICAL PARTS

8

2.3.1 MOTOR

8

2.3.2 COMPRESSOR

8

2.3.3 CAPACITOR

8

2.3.4 POWER CORD

9

2.3.5 THERMISTOR

9

2.4 REFRIGERATION CYCLE

10

2.4.1 CONDENSER

10

2.4.2 EVAPORATOR

10

2.4.3 CAPILLARY TUBE

10

3. TROUBLESHOOTING GUIDE

 

3.1 OUTSIDE DIMENSIONS

13

3.2 PIPING SYSTEM

13

3.3 TROUBLESHOOTING GUIDE

14

4. SCHEMATIC DIAGRAM

 

4.1 CIRCUIT DIAGRAM

19

5. EXPLODED VIEW

20

6. REPLACEMENT PARTS LIST

21

1. PREFACE

This SERVICE MANUAL provides various service information, including the mechanical and electrical parts etc. This room air conditioner was manufactured and assembled under a strict quality control system. The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 SAFETY PRECAUTIONS

1.When servicing the unit, turn off the air conditioner and unplug the power cord.

2.Observe the original lead dress.

If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.

3.After servicing the unit, make an insulation resistance test to protect the customer from being exposed to shock hazards.

1.2 INSULATION RESISTANCE TEST

1.Unplug the power cord and connect a jumper between 2 pins (black and white).

2.The grounding conductor (green or green & yellow) is to be open.

3.Measure the resistance value with an ohm meter between the jumpered lead and each exposed metallic part on the equipment.

4.The value should be over 1M.

—2—

Image 2
Contents Thru-the-Wall Series Contents PrefaceSpecifications For US08B10A/US10B10A/US12B10AFor US10B30A/US12B30B/US14B30A Cooling only Model Operation FeaturesControl Locations VentilationFront Grille Disassembly InstructionsMechanical Parts CabinetAIR Handling Parts ORIFICE, and Turbo FANCapacitor Electrical PartsCompressor Power Cord Electronic Control BoardEvaporator Refrigeration CycleCondenser Capillary TubePage Pulling Vacuum Piping System Troubleshooting GuideOutside Dimensions Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Schematic Diagram Circuit DiagramExploded View Replacement Parts List Model US08B10AModel US10B10A Model US12B10A Model US10B30A Model US12B30B Model US14B30A Friedrich AIR Conditioning CO
Related manuals
Manual 6 pages 41.89 Kb

US10B30A, US14B30A, US10B10A, US08B10A, US12B10A specifications

The Friedrich US12B10A, US08B10A, US10B10A, US14B30A, and US10B30A units signify a leap forward in heating and cooling technology, designed to offer efficient climate control for residential and commercial spaces. Each model boasts a range of features aimed at optimizing comfort while minimizing energy consumption.

The US12B10A model stands out with its impressive 12,000 BTU cooling capacity, making it suitable for larger rooms or spaces needing substantial cooling power. It integrates advanced inverter technology, which adjusts the compressor's speed to achieve the desired temperature with minimal energy wastage. This ensures quieter operation and improved efficiency compared to traditional cooling systems.

Meanwhile, the US08B10A is designed for smaller spaces, providing 8,000 BTU of cooling and heating capacity. Despite its compact size, it employs the same inverter technology found in its larger counterparts, guaranteeing consistent comfort without incurring high energy costs. The model is also equipped with an energy-saving mode, which further enhances its efficiency during off-peak usage.

The US10B10A unit is a versatile option that combines the features of both cooling and heating, with a balanced 10,000 BTU output. This dual functionality is ideal for transitional climates where heating needs may occasionally intersect with cooling demands. The system's user-friendly interface allows for easy adjustments between cooling and heating modes, enhancing user experience.

In contrast, the US14B30A brings a robust 14,000 BTU output, making it perfect for significantly larger spaces or commercial applications. Its energy efficiency rating is top-notch, ensuring a sustainable approach to heating and cooling. This model also features a programmable thermostat, allowing users to set specific schedules for operation, thereby optimizing energy use.

Lastly, the US10B30A also provides a robust 10,000 BTU of capacity but focuses on advanced filtration technology. With a multi-stage filtration system, it effectively captures allergens and particulate matter, contributing to improved indoor air quality. This feature is particularly beneficial for families with allergy sufferers or respiratory conditions.

Overall, the Friedrich series offers a comprehensive array of models built on the foundation of efficiency, versatility, and advanced technology, catering to various needs while promoting a sustainable future. Each unit delivers reliable performance, making them an excellent choice for anyone seeking optimized climate control solutions.