Friedrich US14B30A manual Features, Control Locations, Cooling only Model Operation, Ventilation

Page 5

1.4 FEATURES

Designed for cooling only.

Powerful and quiet.

Slide out chassis for the simple installation and service.

Built in adjustable THERMOSTAT.

Washable one-touch filter.

Compact size.

1.5 CONTROL LOCATIONS

1.5.1COOLING ONLY MODEL

• OPERATION

REMOTE CONTROL SIGNAL RECEIVER

TEMPERATURE SETTING

• Use this button to automatically control the temperature of the room. The temperature can be set within a range of 60° F to 86° F by increments of 1° F.

• The setting appears in the display.

 

 

 

 

 

POWER

 

 

 

 

 

 

 

 

 

 

• To turn the air conditioner ON, push this button.

 

 

 

 

 

To turn the air conditioner OFF, push the button again.

TIMER

• This button takes priority over any other button.

- SHUT-OFF TIME

• When you first turn it on, the unit is in cool mode, at High fan

speed, and set at a temperature setting of 72° F.

• You will usually use shut-off time while you sleep.

 

• If unit is running, use Timer to set number of

FAN SPEED

hours until shut-off.

• For your sleeping comfort, once Timer is set, the

• Every time you push this button, it advances the setting as follows:

Temperature setting will raise 2° F after 30 min.,

{High Low Med High}

and once again after another 30 min.

 

Push Timer button to advance setting from 1 Hour 2 Hours .... 12 Hours maximum.

-START TIME

If unit is off, use Timer to set number of hours before unit starts.

Push Timer button to advance setting from 1 Hour 2 Hours ..... 12 Hours maximum.

MODE

-Push this button to shift mode of operation from COOL MONEY SAVER FAN.

-COOL :

Fan runs continuously for normal cooling operation.

-MONEY SAVER:

The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit will check the room air to determine if cooling is needed.

-FAN :

Fan-only operation.

VENTILATION

Push the lever to the "CLOSE" position to cool, heat or recirculate room air only.

Pull the lever to the "OPEN" position to exhaust smoke or stale air from the room.

This feature is best used in conjunction with the FAN ONLY position.

CAUTION

When the air conditioner has been operating in the

PULL OPEN / PUSH CLOSE

cooling and is turned off or set to the fan only position,

 

wait at least 3 minutes before resetting to the cooling

 

operation again.

 

—5—

Image 5
Contents Thru-the-Wall Series Preface ContentsFor US08B10A/US10B10A/US12B10A SpecificationsFor US10B30A/US12B30B/US14B30A Control Locations FeaturesCooling only Model Operation VentilationMechanical Parts Disassembly InstructionsFront Grille CabinetORIFICE, and Turbo FAN AIR Handling PartsCapacitor Electrical PartsCompressor Electronic Control Board Power CordCondenser Refrigeration CycleEvaporator Capillary TubePage Pulling Vacuum Piping System Troubleshooting GuideOutside Dimensions Troubleshooting Guide Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage Limits Complaint Cause Remedy Circuit Diagram Schematic DiagramExploded View Model US08B10A Replacement Parts ListModel US10B10A Model US12B10A Model US10B30A Model US12B30B Model US14B30A Friedrich AIR Conditioning CO
Related manuals
Manual 6 pages 41.89 Kb

US10B30A, US14B30A, US10B10A, US08B10A, US12B10A specifications

The Friedrich US12B10A, US08B10A, US10B10A, US14B30A, and US10B30A units signify a leap forward in heating and cooling technology, designed to offer efficient climate control for residential and commercial spaces. Each model boasts a range of features aimed at optimizing comfort while minimizing energy consumption.

The US12B10A model stands out with its impressive 12,000 BTU cooling capacity, making it suitable for larger rooms or spaces needing substantial cooling power. It integrates advanced inverter technology, which adjusts the compressor's speed to achieve the desired temperature with minimal energy wastage. This ensures quieter operation and improved efficiency compared to traditional cooling systems.

Meanwhile, the US08B10A is designed for smaller spaces, providing 8,000 BTU of cooling and heating capacity. Despite its compact size, it employs the same inverter technology found in its larger counterparts, guaranteeing consistent comfort without incurring high energy costs. The model is also equipped with an energy-saving mode, which further enhances its efficiency during off-peak usage.

The US10B10A unit is a versatile option that combines the features of both cooling and heating, with a balanced 10,000 BTU output. This dual functionality is ideal for transitional climates where heating needs may occasionally intersect with cooling demands. The system's user-friendly interface allows for easy adjustments between cooling and heating modes, enhancing user experience.

In contrast, the US14B30A brings a robust 14,000 BTU output, making it perfect for significantly larger spaces or commercial applications. Its energy efficiency rating is top-notch, ensuring a sustainable approach to heating and cooling. This model also features a programmable thermostat, allowing users to set specific schedules for operation, thereby optimizing energy use.

Lastly, the US10B30A also provides a robust 10,000 BTU of capacity but focuses on advanced filtration technology. With a multi-stage filtration system, it effectively captures allergens and particulate matter, contributing to improved indoor air quality. This feature is particularly beneficial for families with allergy sufferers or respiratory conditions.

Overall, the Friedrich series offers a comprehensive array of models built on the foundation of efficiency, versatility, and advanced technology, catering to various needs while promoting a sustainable future. Each unit delivers reliable performance, making them an excellent choice for anyone seeking optimized climate control solutions.