Milwaukee m12 cpd manual ON/OFF switch is not pressed. Always allow

Page 7

The torque specications shown here are approximate values obtained with a fully charged battery pack.

 

 

 

 

 

 

1-5

5-15

Small screws in softwood.

6-10

16-22

Medium screws in softwood or small

11-15

23-28

screws in hardwood.

16-18

29-40

Large screws in softwoods. Medium

screws in hardwood or large screws in

 

 

hardwood with pilot hole.

Because the settings shown in the table are only a guide, use a piece of scrap material to test the different clutch settings before driving screws into the workpiece.

The speed selector is on top of the motor housing.

Allow the tool to come to a complete stop before

changing speeds. See “Applications” for recom-

mended speeds under various

conditions.

speed, push the

1.

For

2.

speed selector to display “1”.

For

speed, push the

 

speed selector to display “2”.

The control switch may be set to three positions:

forward, reverse and lock. Due to a lockout mecha-

nism, the control switch can only be adjusted when

the ON/OFF switch is not pressed. Always allow

the motor to come to a complete stop before using

the control switch.

 

For

(clockwise) rotation,

 

push in the control switch from the

 

right side of the tool.

 

For

(counterclockwise)

 

rotation, push in the control switch

 

from the left side of the tool.

LEFT

 

To

the trigger, push the control

 

switch to the center position. The

 

trigger will not work while the con-

 

trol switch is in the center locked

CENTER

position. Always lock the trigger

 

or remove the battery pack before

 

performing maintenance, changing

 

accessories, storing the tool and

 

any time the tool is not in use.

 

1.To the tool, grasp the handle rmly and pull the trigger.

NOTE: An LED is turned on when the trigger is pulled.

2.To the speed, increase or decrease the pressure on the trigger. The further the trigger is pulled, the greater the speed.

3.To the tool, release the trigger. Make sure the bit comes to a complete stop before laying the tool down.

To protect the battery from damage and extend its life, the tool’s intelligent circuit monitors current draw, temperature, and voltage drops.

In extremely high torque, binding, stalling, and short circuit situations that cause high current draw, the tool will vibrate for about 5 seconds, the fuel gauge will ash, and then the tool will turn OFF. To reset, release the trigger.

Under extreme circumstances, the internal tem- perature of the battery could become too high. If this happens, the fuel gauge will ash and the battery pack will shut off. Let the battery pack cool and then continue work.

7

Image 7
Contents Operators Manual Page Personal Safety General Power Tool Safety WarningsWork Area Safety Electrical SafetyService Inserting/Removing the Battery SpecificationsSymbology AssemblyFuel Gauge OperationON/OFF switch is not pressed. Always allow Applications MaintenanceAccessories Page Page Doncaster, Victoria, Australia West Lisbon Road, Brookfield, Wisconsin U.S.AMt Wellington, Auckland, New Zealand