Wilton 1230 manual Resetting the Stop switch, Using the load ammeter, Using the control lever

Page 12

Resetting the STOP switch

1.Turn the switch in the direction of the arrow on the red button -- clockwise. The switch is reset and the other spindle motor controls can be used.

Using the load ammeter

An ammeter on the control console is used to monitor the load on the spindle drive motor. It is connected into one of the three power lines which supply the main drive motor.

When the drive motor is ON and up to speed, and there is no tooling being used to drill, tap or bore a hole, the ammeter should read approximately 2.5 amps. If it is above this value there is a problem internally (such as lack of lubrication in the gear- boxes, bad bearings, etc.) which means you should turn off the machine and determine the cause of the excessive free-running load.

Monitor the the ammeter during machining operations. The ammeter should stay below 9 amps or current draw during machining. You should adjust your spindle speed, feed rate and coolant use to maintain the full load current draw below the 9 amp value.

If you exceed 9 amps current draw a thermal limiter switch in the electrical control panel will trip. If this occurs, a licensed electrician should be used to locate and re-set the thermal limiter switch.

Using the control lever

The four-position control lever is located on the left hand side of the drill head console. See Figs. 1 and 3.

The control lever can move up or down, back- ward or forward, or can be left in its most central, OFF or neutral position so no functions are under its control power.

The control lever moves up or down to move the arm up or down when positioning the tooling over the work piece. This ability to control the height of the arm is available when:

1.The main power to the machine is ON at its branch service panel.

2.The emergency STOP switch is set to its ON mode.

3.The Control ON/OFF switch (lower left hand side of the face of the drill head, see Fig. 1) pushed ON.

4.The column and arm UNLOCK button (right hand side of the drill head -- see Fig. 1) is pressed to unlock the machine locks. See page 6.

The control lever does not return to neutral when it is released. It stays in the position in which you have placed it. This means unless you return it to neutral, the arm will keep raising or lowering until it contacts one of its limit switches.

When the motor speed control switch has been set to either HI or LOW position, the control lever can be moved backward or forward to turn the spindle drive motor ON and control the direction of rotation of the spindle. The control lever is not spring loaded to return to the neutral or OFF position when you

12

Tapping operations

When performing tapping operations :

1.Determine the most efficient tapping speed (spindle speed) by consulting appropriate machinist's tables, your tap supplier, coolant supplier and/or work piece supplier.

2.Be certain the power feed dial is in N or neutral position. See Setting power feed rate, page 8.

3.Turn the spindle motor ON. Also, turn on the coolant pump if coolant is being used.

4.Move the control lever to FORWARD.

5.Use the feed levers to move the tap into its pilot hole until the tap makes its initial thread cut and is engaged in the workpiece.

6.Allow the tap to "self feed" into the pilot hole until it has completed its tapping operation.

7.Move the control lever into its center/neutral position until the spindle has come to a complete stop.

8.Move the control lever into its reverse direction so the tap unscrews itself from the hole it has just

threaded.

Figure 3: Control lever for spindle and arm.

Image 12
Contents Operating instructions and parts manual Revision aPage Table of Contents General specifications Overall dimensions and specificationsMachining capacities Machinery general safety warnings Wire sizes Safety instructions on drill pressesGeneral Electrical Cautions Operating Instructions Clamping workpieces to the machineInserting tooling To insert toolingTo remove tooling Positioning the tooling over the workpieceSetting spindle speed Setting feed rate and depth of cutSetting feed rate Moving the arm on the support columnSetting depth of cut using the power feed system To set the depth of cutSpindle motor controls Resetting the Stop switch Using the load ammeterUsing the control lever Tapping operationsPeriodic maintenance Lubrication diagramMachine set-up Electrical branch service Wiring diagramTo connect the branch to the drill press Wiring diagram Replacement Parts Exploded View Column and Base Parts List Column and Base Parts List Column Gear Box Parts List Arm Front Exploded View Arm Rear Parts List Arm Rear Parts List Riser Mechanism Exploded View Head Parts List Head Parts List Head Parts List Rear of Head Parts list Flood Coolant System Page Page South Hicks Road Palatine, IL TEL FAX