2.Using #10 x ⁷⁄₈" pan-head Phillips screws, attach bracket to cabinet. Repeat for other bracket.

3.Loosen locking nut and turn the adjustment bolt (C) for each bracket until the bolt touches the wall (B).

4.Tighten the locking nut on adjustment bolt to lock in position.

A

B

C

Complete Installation

1.Insert seal behind the top of the lower window sash and against the glass of the upper window (B).

2.Place one window-lock bracket on top of lower window and against upper window sash on each side of window (A).

3.Use a ³⁄₃₂" drill bit to drill a starter holes through the holes in each bracket into the window sash.

4.Attach both window-lock brackets to window sash with #10 x ³⁄₄" round-head screws to secure window in place.

C

B

A A

A. Support bracket

B. Locking nut

C. Adjustment bolt

A. Window lock brackets

B. Window rail seal

C. Upper window glass

Through-the-Wall Cabinet Installation

NOTES:

Handle air conditioner gently.

Be sure your air conditioner cabinet does not fall out of the opening during installation or removal.

The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded 3 prong outlet.

It is the customer's responsibility and obligation to have this product installed by a qualified technician familiar with through-the-wall room air conditioner installations.

Do not block the louvers on the front panel.

Do not block the louvers on the outside of the air conditioner.

Option 2—Plastered wall with no molding

If the plastered wall is to be flush with the cabinet and no molding is used, the wood frame must be set ¹⁄₂" (13 mm) into the inside wall.

A B C

D

Option 1—Wood, metal or plastic molding

When using a wood, metal or plastic molding, the wood frame should line up with inside wall as shown.

A B C

D

A. Trim Molding

C. Wood wall framing

B. Inside wall

D. Louvers

surface

A. Plastered wall

C. Wood frame

B. Inside wall

D. Louvers

Install Wood Frame

1.Construct wood frame. See “Location Requirements” for dimensions.

2.Measure outside width and height of frame to determine wall opening dimensions.

3.Cut opening through the wall. Remove and save insulation.

NOTES:

Dimension for depth depends on wall thickness and type of molding.

Do not block louvers in air conditioner cabinet.

9

Image 9
Contents Operating Guide Room Air Conditioner with remote controlTable of Contents Tools and Parts Installation RequirementsLocation Requirements Parts supplied on some modelsElectrical Requirements Recommended grounding method Remove packaging materials Installation InstructionsAttach foam adhesive seal Bottom viewTop view Install Cabinet into Window Attach Support BracketsFront View Top View Complete Installation Through-the-Wall Cabinet InstallationInstall Wood Frame Option 2-Plastered wall with no moldingInstall Cabinet into Wood Frame Complete InstallationAir Conditioner Use Timer Delay TemperatureMode Money SaverTo raise the temperature To operate air conditioner with remote controlTroubleshooting Air conditioner will not operateAir conditioner blows fuses or trips circuit breakers Temperature on display does not match room temperature Assistance or ServiceAir conditioner seems to run too much Water drips from cabinet into your houseRoom AIR Conditioners Limited Warranty
Related manuals
Manual 28 pages 12.45 Kb

CP24, CP18, CP14 specifications

Friedrich CP14, CP18, and CP24 are part of a renowned line of energy-efficient portable air conditioners designed to provide optimal cooling performance in a variety of environments. These models are especially popular for their versatility, making them ideal for residential, office, and commercial use. Each unit brings unique features and technologies that cater to different cooling requirements.

One of the standout features of the Friedrich CP series is its impressive cooling capacity. The CP14 model delivers 14,000 BTUs, the CP18 offers 18,000 BTUs, and the CP24 ramps it up to an impressive 24,000 BTUs, making them suitable for spaces ranging from small rooms to larger areas. This range allows users to select the most appropriate model based on their specific cooling needs, ensuring optimal comfort.

The CP series is equipped with an advanced air filtration system that captures dust, allergens, and other particulates from the air, resulting in cleaner and healthier indoor air quality. The reusable and washable filter not only enhances air quality but also reduces maintenance and long-term costs.

Friedrich also incorporates smart technology into the CP series, making these units easy to operate through a user-friendly control panel or remote control. The models feature comprehensive programming options, including a 24-hour timer and adjustable fan speeds, providing consumers with the flexibility to customize their cooling experience based on personal preferences.

Energy efficiency is a primary focus in the design of the CP14, CP18, and CP24 models. Each unit boasts an impressive Energy Efficiency Ratio (EER), which helps reduce electricity bills while minimizing environmental impact. The eco-friendly refrigerants used in these portable air conditioners further contribute to their environmentally conscious design.

Durability and mobility are key characteristics of the Friedrich CP series. Each unit comes equipped with casters that allow easy movement from room to room, while their compact design makes storage convenient when not in use. The robust build quality ensures that these air conditioners can withstand frequent transportation and use.

In summary, Friedrich CP14, CP18, and CP24 portable air conditioners are engineered to provide powerful cooling performance along with energy efficiency and user-friendly operation. With their advanced air filtration, customizable settings, and mobility features, these units are a perfect choice for anyone looking to enhance their indoor comfort. Whether cooling a small bedroom or a larger living space, Friedrich's CP series delivers reliable and efficient performance for all cooling needs.