Friedrich CP10A10, ZQ08B10, ZQ10B10, CP08A10, CP12A10 manual Contents, Preface

Page 2

CONTENTS

1. PREFACE

 

1.1 SAFETY PRECAUTIONS

2

1.2 INSULATION RESISTANCE TEST

2

1.3 SPECIFICATIONS

3

1.4 FEATURES

4

1.5 CONTROL LOCATIONS

4

2. DISASSEMBLY INSTRUCTIONS

 

2.1 MECHANICAL PARTS

6

2.1.1 FRONT GRILLE

6

2.1.2 CABINET

6

2.1.3 CONTROL BOX

6

2.2 AIR HANDLING PARTS

7

2.2.1 AIR GUIDE AND TURBO FAN

7

2.2.2 FAN

7

2.2.3 SHROUD

8

2.3 ELECTRICAL PARTS

8

2.3.1 OVERLOAD PROTECTOR

8

2.3.2 COMPRESSOR

8

2.3.3 CAPACITOR

9

2.3.4 POWER CORD

9

2.3.5 MOTOR

10

2.4 REFRIGERATION CYCLE

10

2.4.1 CONDENSER

10

2.4.2 EVAPORATOR

10

2.4.3 CAPILLARY TUBE

11

3. TROUBLESHOOTING GUIDE

 

3.1 OUTSIDE DIMENSIONS

13

3.2 PIPING SYSTEM

14

3.3 TROUBLESHOOTING GUIDE

15

4. SCHEMATIC DIAGRAM

19

5. EXPLODED VIEW

20

6. REPLACEMENT PARTS LIST

21

1. PREFACE

This SERVICE MANUAL provides various service information, including the mechanical and electrical parts etc. This room air conditioner was manufactured and assembled under a strict quality control system. The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.

1.1 SAFETY PRECAUTIONS

1.When servicing, turn the unit Off and unplug the power cord.

2.Observe the original lead dress.

If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit.

3.After servicing, make an insulation resistance test to prevent the customer from being exposed to shock hazards.

1.2 INSULATION RESISTANCE TEST

1.Unplug the power cord and connect a jumper between 2 pins (black and white).

2.The grounding conductor (green or green and yellow) is to be

.open.

3.Measure the resistance value with an ohm meter between the

.jumpered lead and each exposed metallic part on the equip- ment at each working status.

4.The value should be over 1 M.

Ñ2Ñ

Image 2
Contents Room Air Conditioner Service and Parts Manual Contents PrefaceSpecifications Or ZQ08B 10,ZQ10B 10,C P 08A10,C P 10A10,C P 12A10Features Control LocationsDIS P L AY Mote C Ontr OL Front Grille Disassembly InstructionsMechanical Parts CabinetAIR Handling Parts AIR Guide and Turbo FANElectrical Parts 2.3.1 Overload Protector CompressorPower Cord CapacitorEvaporator Refrigerating CycleCondenser Caution Capillary Tube Pulling Vacuum MODELCP10A10,CP12A10 Troubleshooting GuideOutside Dimensions Piping System Room AIR ConitionerUnit runs but poor cooling Ineffective Cooling Fails to Start Complaint Cause Remedy Complaint Cause Remedy Schematic Diagram Model ZQ08B10,ZQ10B10Exploded View W0CZZReplacement Parts List ZQ08B10ZQ10B10 CP08A10 CP10A10 CP12A10 Memo Memo Use Factory Certified Parts

CP12A10, CP08A10, CP10A10, ZQ10B10, ZQ08B10 specifications

The Friedrich ZQ08B10, CP12A10, ZQ10B10, CP10A10, and CP08A10 represent a series of highly efficient and innovative units designed for heating and cooling applications. These systems are tailored to meet various environmental and operational demands, making them ideal for both residential and commercial sectors.

One of the main features of the Friedrich ZQ series is their energy efficiency. Equipped with advanced inverter technology, these units adjust their cooling and heating output based on the room's temperature, consuming less energy and reducing utility bills. This feature not only promotes a greener environment but also enhances users' comfort with consistent temperature control.

The ZQ08B10 and ZQ10B10 units excel in their cooling and heating capacities, making them suitable for varying room sizes. With a strong focus on versatility, these units can be installed in different configurations, including wall-mounted or ceiling-integrated systems, allowing for effective integration into existing spaces.

Another key characteristic is the quiet operation of these models. Friedrich has engineered its compressors and fans to minimize noise levels, providing a serene indoor environment. This is particularly beneficial for settings where noise can be a distraction, such as schools, offices, or residential bedrooms.

The CP series, which includes the CP08A10, CP10A10, and CP12A10, is celebrated for its smart technology features. These models come equipped with Wi-Fi connectivity, enabling users to control settings remotely via smartphone applications. This feature adds convenience and enhances energy management, allowing users to schedule operations and monitor energy consumption from anywhere at any time.

Additionally, the CP units include enhanced filtration systems designed to improve indoor air quality. Their multi-stage filters capture dust, allergens, and airborne particles, promoting a healthier living environment. This is a critical factor for households with allergy sufferers or individuals with respiratory issues.

Overall, the Friedrich ZQ08B10, CP12A10, ZQ10B10, CP10A10, and CP08A10 models stand out due to their energy efficiency, quiet operation, and smart technology features. They embody the perfect blend of performance, comfort, and advanced features, making them a valuable consideration for consumers looking for reliable heating and cooling solutions. As technology continues to evolve, these units maintain a strong position by adapting to user needs, ensuring lasting satisfaction and sustainability.