Lincoln 60 manual Location, High Frequency Interference Protection

Page 9

INSTALLATION

SAFETY PRECAUTIONS

Read the safety precautions at the beginning of this Operator's Manual before proceeding.

Only personnel that have read and under- stood this Operator’s Manual should install and operate this equipment.

Machine must be connected to system ground per any national, local or other applicable electrical codes.

The power switch is to be in the “OFF” position when connectiong power cord to input power.

WARNING

TURN THE INPUT POWER OFF USING THE DISCONNECT SWITCH AT THE FUSE BOX BEFORE ATTEMPTING TO CONNECT THE INPUT POWER LINES.

Only qualified personnel should perform this installa- tion.

Turn the power switch on the PRO-CUT “off” before connecting or disconnecting output cables.

Connect the PRO-CUT grounding terminal located on the side of the case back to a good electrical earth ground.

------------------------------------------------------------------------

LOCATION

Place the PRO-CUT where clean cooling air can freely circulate in through the front intake and out through the rear louvers. Dirt, dust or any foreign material that can be drawn into the machine should be kept at a minimum. Failure to observe these precau- tions can result in excessive operating temperatures and nuisance shutdown of the machine. Before plan- ning the installation, read the section entitled “High Frequency Interference Protection”.

A source of clean, dry, compressed air or nitrogen must be supplied to the PRO-CUT. Oil in the air is a severe problem and must be avoided. The supply pressure must be between 70 and 120 psi (482 and 827 kPa). The flow rate is approximately 4.7 cfm (133 l/min.). Failure to observe these precautions could result in excessive operating temperatures or damage to the torch.

HIGH FREQUENCY INTERFERENCE PROTECTION

Since the spark gap oscillator in the high frequency generator in the machine is similar to a radio transmit- ter, improper machine installation can result in radio and TV interference or problems with nearby electron- ic equipment.

Radiated interference can develop in the following four ways:

(1)Direct interference radiated from the machine.

(2)Direct interference radiated from the cutting leads.

(3)Direct interference radiated from feedback into the power lines.

(4)Interference from reradiation of “pickup” by ungrounded metallic objects.

Keeping these contributing factors in mind, installing equipment per the following instructions should mini- mize problems.

(1)Keep the machine power supply lines as short as possible.

(2)Keep the work and torch leads as short as possi- ble and as close together as possible. Lengths should not exceed 50 ft. (15.2 m). Tape the leads together when practical.

(3)Be sure the torch and work cable rubber cover- ings are free of cuts and cracks that allow high frequency leakage.

(4)Keep the torch in good repair and all connections tight to reduce high frequency leakage.

(5)Keep all access panels and covers securely in place

NOTE: The machine frame MUST also be grounded - see CAUTION under “Input Connection”, sec- tion. The work terminal ground does not ground the machine frame.

(6)When the machine is enclosed in a metal build- ing, several good earth driven electrical grounds around the periphery of the building are recommended.

Failure to observe these recommended installation procedures may cause radio or TV interference prob- lems and result in unsatisfactory cutting or gouging performance resulting from lost high frequency power.

– 9 –

Image 9
Contents OPERATOR’S Manual Electric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéTable of Contents Please Examine Carton and Equipment For Damage Immediately Specifications Preheat Temperature for Plasma Cutting Product DescriptionUser Responsibility High Frequency Interference Protection LocationElectric Shock can kill Input ConnectionsTorch Connection Output ConnectionsSequence of events High Frequency Shock can Cause Injury or FallPilot Arc Discussion Procedure RecommendationsGeneral Thin Gauge Sheet MetalExpanded Metal Thick Sections of MetalGouging Suggestions for Extra Utility from the PRO-CUT System All CasesElectrical Shock can Kill Routine MaintenanceSymptom Check Power Before Adjusting the HighFrequency Circuit Symptom Check Symptom Check Status Lights Condition Suggestions PRO-CUT 60 Status Lights Operating ModesSafety Procedure for Replacing PC Boards Electric Shock can Kill Wiring Diagram PRO-CUT 60 Single Phase Dual Voltage PRO-CUT 60 Power Source Cutting Torch Connection Diagram For Magnum PCTPage Ship Manuals to Total New Lessons in Arc Welding How To Read Shop DrawingsNeed Welding Training? Basic CoursePrecaucion Warnung

60 specifications

The Lincoln 60, a luxury vehicle produced by the Lincoln Motor Company, represents a blend of elegance, performance, and innovation. Launched during the post-war era, the Lincoln 60 is renowned for its striking design, advanced technologies, and distinctive character.

One of the most notable features of the Lincoln 60 is its iconic styling. The vehicle showcases a long, sleek silhouette that embodies the sophistication of American luxury automobiles. With its prominent grille, sweeping lines, and bold presence, the Lincoln 60 commands attention on the road. The interior is equally impressive, featuring high-quality materials, spacious seating arrangements, and meticulous craftsmanship that exudes opulence. Plush leather upholstery, wood accents, and cutting-edge dashboard layouts create an inviting atmosphere for both drivers and passengers.

In terms of performance, the Lincoln 60 is equipped with a powerful V8 engine that delivers exhilarating acceleration and smooth handling. The vehicle's engineering emphasizes a balance between performance and comfort, making it suitable for both leisurely cruises and highway driving. The advanced suspension system ensures a smooth ride, effectively absorbing bumps and imperfections in the road.

The Lincoln 60 is also a pioneer in automotive technology. Early models featured innovations such as power windows, power seats, and air conditioning, which were considered luxury items at the time. Over the years, the Lincoln 60 has continued to incorporate modern technological advancements, including advanced infotainment systems, navigation, and enhanced sound systems, making journeys not only more enjoyable but also more connected.

Safety has always been a priority for Lincoln, and the 60 is no exception. Equipped with features such as power brakes, seatbelts, and enhanced chassis design, the vehicle is built to provide a secure driving experience.

With its combination of style, performance, and luxury, the Lincoln 60 stands out as a hallmark of American automotive excellence. The enduring appeal of this prestigious vehicle is a testament to Lincoln's commitment to quality and innovation, ensuring that the Lincoln 60 remains a symbol of luxury for years to come. Whether navigating city streets or embarking on cross-country adventures, the Lincoln 60 delivers a driving experience that is both sophisticated and enjoyable.