Friedrich CP18C30 manual Recommended grounding method, Power Supply Cord

Page 5

Recommended grounding method

This air conditioner must be grounded. This air conditioner is equipped with a power supply cord having a grounded 3 prong plug. To minimize possible shock hazard, the cord must be plugged into a mating, grounded 3 prong outlet, grounded in accordance with all local codes and ordinances. If a mating outlet is not available, it is the customer's responsibility to have a properly grounded 3 prong outlet installed by a qualified electrical installer.

It is the customer's responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 - latest edition, and all local codes and ordinances.

Copies of the standards listed may be obtained from:

National Fire Protection Association One Batterymarch Park

Quincy, MA 02269

Power Supply Cord

NOTE: Your unit’s device may differ from the ones shown.

B A

TEST

RESET

TEST

RESET

BA

A.Reset button

B.Test button

This room air conditioner is equipped with a power supply cord required by UL. This power supply cord contains state-of-t he-art electronics that sense leakage current. If the cord is crushed, the electronics detect leakage current and pow er will be disconnected in a fraction of a second.

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet. Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

To test your power supply cord:

1.Plug power supply cord into a grounded 3 prong outlet.

2.Press RESET.

3.Press TEST (listen for click; Reset button will trip and pop out).

4.Press and release RESET (listen for click; Reset button will latch and remain in). The power supply cord is ready for operation.

NOTES:

The Reset button must be pushed in for proper operation.

The power supply cord must be replaced if it fails to trip when the test button is pressed or fails to reset.

Do not use the power supply cord as an off/on switch. The power supply cord is designed as a protective device.

A damaged power supply cord must be replaced with a new power supply cord obtained from the product manufacturer and must not be repaired.

The power supply cord contains no user serviceable parts. Opening the tamper-resistant case voids all warranty and performance claims.

5

Image 5
Contents 66121417 Room Air Conditioner with remote controlTable of Contents Location Requirements Installation RequirementsTools and Parts Through-the-wall installation Window installationPower supply Cord Electrical RequirementsRecommended grounding method Power Supply CordRemove packaging materials Installation InstructionsAttach Side Curtains Attach Top ChannelAttach foam adhesive seal Bottom viewAttach Side Curtains to Window Frame Install Cabinet into WindowAttach Support Brackets Front View Top ViewComplete Installation Through-the-Wall Cabinet InstallationInstall Wood Frame Option 1-Wood, metal or plastic moldingInstall Cabinet into Wood Frame Complete InstallationAir Conditioner Use Starting Your Air Conditioner-Digital Control To raise the temperature To operate air conditioner with remote controlAir Conditioner Care TroubleshootingTemperature on display does not match room temperature Assistance or ServiceAir conditioner seems to run too much Water drips from cabinet into your houseRoom AIR Conditioners Limited Warranty