How to Install the Unit

1.To prevent vibration and excess noise, make sure the unit is installed securely and firmly

2. Install the unit where the sunlight does not

Cooled air

shine directly on the unit.

 

3.The outside of the cabinet must extend outward for at least 12" and there shouldbe no obstacles,

such as a fence or wall,within 20" from the back

 

 

30"~60"

of the cabinet, as it will prevent heat radiation

 

 

of the condenser.

Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

Fence

Awning

Heat radiation

About 1/2"

Over 20"

ENGLISH

CAUTION: DO NOT cover or block any of the side louvers. All side louvers of the cabinet must remain exposed and unobstructed to the outside of the structure.

4.Install the unit with a rear, downward slope, so the back is slightly lower than the front (about 1/4" bubble on a level). This will force condensation to flow to the outside.

5.Install the unit with the bottom about 30"-60" above the floor level.

Window Requirements

NOTE: All supporting parts should be secured to firm wood, masonry, or metal.

This unit is designed for installation in standard double hung windows with actual opening widths from 27" to 39".

The top and bottom window sash must open sufficiently to allow a clear vertical opening of 16" from the bottom of the upper sash to the window stool.

27" to 39"

 

 

16" min

Stool

(With frame curtain)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interior wall

23 5/8" min.

(Without frame curtain)

Offset

1/2" to 11/4"

Sill

Exterior

10

Image 11
Contents CP10 CP12 Table of Contents 115V~ 230V~ IntroductionBefore Operating Your Unit For the Best Cooling Performance and Energy EfficiencyNever Do This Always Do This Safety PrecautionsPage Dry operation. dehumidify operation To receive the signal from remote controllerVent Control Adjusting the Air Flow DirectionAdjusting the Air Flow Direction Drainage Care and MaintenanceAir Filter Brace Product FeaturesVertical Louver Cabinet Air IntakeInlet Grille Front GrillInstallation Instructions Cabinet, as it will prevent heat radiation How to Install the UnitWindow Requirements Shine directly on the unitInstallation Kit Contents Suggested Tool Requirements Window stool. Fig Cabinet InstallationOpen the window. Mark a line on center About Power cord ScrewType aWindow locking bracket Through-the-Wall Installation Instructions-Optional Troubleshooting Tips Room AIR Conditioners Limited Warranty Page De votre climatiseur de pièce Table des matières 115V~ Avant dutiliser votre appareilAvertissement Mesures de SécuritéBords POINTUS! Les bords du cas peuvent être pointus Oscillation Automatique Fonctionnement de la télécommande CPRéglage de l’orientation du débit d’air Commande de l’orifice de ventilationRéglage de lorientation du débit dair Filtre à air Soins et entretienCaractéristiques particulières de l’appareil Installation du matérielPage Sans volets détanchéité Décalage To 11/4 Seuil Extérieur Installation de l’appareilDimensions de fenêtre minimales 27 à 16min. RebordContenu du nécessaire d’installation Préparation DU Cadre Outils recommandésSerrez pas. Fig Installation du boîtierAngle avant Cordon Dalimentation Vis Type a 1 Vis Type aÉtrier de verrouillage de fenêtre Installation sur le mur Instruction facultative Page Garantie limitée Climatiseurs Friedrich Model information can be found on the name plate located on CP LinesContenidos Provee buen flujo de aire IntroducciónAdvertencia Precaucion Precauciones de segoridadPrecaucion Med Funcionamiento del control remoto CPDos Ajustar la dirección del flujo de aire Ajustar la dirección del flujo de aireControl de ventilación Drenaje Cuidado y mantenimientoFiltro de Aire a Funciones del producto Instalación de la unidadPage Saliente Cómo instalar la unidadRequisitos de la ventana 27 a Min asiento Con el marco de la cortinaContenidos de los conjuntos de instalación Preparación DEL Chasis Requisitos sugeridos de las ventanasInstalación del gabinete Tire cada marco de la cortina Al dintel 6 para equilibrar el gabineteColocando los tornillos 2 Tipo B Largo Ángulo frontal en el asiento de la ventanaAbrazadera de fijación Español Instrucciones de instalacion a traves de la pared opcional Español Garantia Limitada -PRIMER AÑO Friedrich AIR Conditioning CO
Related manuals
Manual 58 pages 2.08 Kb

CP10, CP12 specifications

The Friedrich CP10 and CP12 are advanced air conditioning units designed to provide optimal cooling and ventilation solutions for various applications. These models are particularly known for their innovative technologies and user-friendly features that prioritize efficiency and comfort.

One of the standout characteristics of both the CP10 and CP12 is their energy efficiency. They are equipped with advanced inverter technology, which allows the units to adjust their power output based on real-time cooling demands. This not only helps to reduce energy consumption but also minimizes noise levels, making these units ideal for residential and commercial settings alike.

The CP10 and CP12 feature a sleek and modern design, ensuring that they blend seamlessly into any environment. Their compact size makes them easy to install and suitable for a variety of spaces, from small rooms to larger commercial areas. Both models come with a built-in digital thermostat, allowing users to set and maintain their desired temperature with precision.

In terms of air filtration, the units are equipped with high-efficiency particulate air (HEPA) filters, which trap dust, allergens, and other airborne particles. This feature significantly improves indoor air quality, making the CP10 and CP12 perfect for users with respiratory issues or allergies. Furthermore, the filters are easily accessible, making maintenance simple and straightforward.

Connectivity is another key feature of the CP10 and CP12. They come with Wi-Fi capabilities, allowing users to control their air conditioning units remotely via a smartphone app. This convenience enables homeowners and business operators to adjust settings, track energy usage, and schedule operation times from anywhere.

Additionally, both models incorporate smart technology that enhances their usability. They can learn user preferences and automatically adjust cooling patterns to optimize comfort while ensuring energy savings. The intuitive user interface allows for easy navigation and customization, accommodating diverse user needs.

Durability is also a hallmark of the Friedrich CP10 and CP12. Constructed with high-quality materials, these units are designed to withstand various environmental conditions, ensuring longevity and reliable performance. The robust build quality minimizes the need for frequent repairs and maintenance, providing peace of mind for users.

In summary, the Friedrich CP10 and CP12 air conditioning units are exemplary models that embody energy efficiency, innovative technology, and user-friendly features. With their advanced cooling capabilities, superior air filtration, connectivity options, and robust design, they serve as ideal solutions for maintaining comfortable indoor environments in both residential and commercial spaces.