Friedrich CP10, CP12 manual Introduction, Before Operating Your Unit, 115V~ 230V~

Page 3

Introduction

Before Operating Your Unit

Make sure the wiring is adequate for your unit.

If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1.

DO NOT use an extension cord.

The cord provided will carry the proper amount of electrical power to the unit; an extension cord will not.

Make sure that the receptacle is compatible with the wall plug provided.

This insures proper grounding. If you have a two-prong receptacle you will need to have the circuit replaced by a certified electrician with a grounded circuit that meets all national and local codes and ordinances. You must use the three-prong plug furnished with the air conditioner.

 

CIRCUIT RATING OR

PLUG FACE

 

MODEL

TIME DELAY

FUSE

 

 

 

 

AMP

VOLT

NEMA NO.

 

CP10 CP12

15

125

5-15P

Figure 1

 

 

 

 

115V~

230V~

Power cord may include a current

 

 

 

interrupter device. A test and reset button is

 

 

 

provided on the plug case. The device

 

 

 

should be tested on a periodic basis by first

 

 

 

pressing the TEST button and then the

 

 

 

RESET button. If the TEST button does not

 

 

 

trip or if the RESET button will not stay

 

 

 

engaged, discontinue use of the air

 

 

 

conditioner and contact a qualified service

 

 

 

technician.

 

 

I L G N E

N OT E !

Aluminum house wiring may pose special problems. Consult a qualified electrician.

For the Best Cooling Performance and Energy Efficiency

Keep the filter clean

Make sure that your air conditioner is always in top performing condition by cleaning the filter regularly. Instructions for removing and cleaning the filter can be found on page 7.

Provide good air flow

Make sure that the airflow to and from the unit is clear. Your air conditioner puts the air out at the side of the unit, and takes in air at the left. Airflow is critical for good operation. It is just as important on the outside of the building that the airflow around the unit exterior is not blocked.

Unit Placement

If your air conditioner can be placed in a window or a wall that is shaded by a tree or another building, the unit will operate even more efficiently. Using drapes or blinds on the sunny side of the dwelling will also add to your unit's efficiency.

Insulation

Good insulation will be a big help in maintaining desirable comfort levels. Doors should have weather stripping. Be sure to caulk around doors and windows.

2

Image 3
Contents CP10 CP12 Table of Contents 115V~ 230V~ IntroductionBefore Operating Your Unit For the Best Cooling Performance and Energy EfficiencyNever Do This Always Do This Safety PrecautionsPage Dry operation. dehumidify operation To receive the signal from remote controllerAdjusting the Air Flow Direction Adjusting the Air Flow DirectionVent Control Care and Maintenance Air FilterDrainage Brace Product FeaturesVertical Louver Cabinet Air IntakeInlet Grille Front GrillInstallation Instructions Cabinet, as it will prevent heat radiation How to Install the UnitWindow Requirements Shine directly on the unitInstallation Kit Contents Suggested Tool Requirements Cabinet Installation Open the window. Mark a line on centerWindow stool. Fig About Power cord ScrewType aWindow locking bracket Through-the-Wall Installation Instructions-Optional Troubleshooting Tips Room AIR Conditioners Limited Warranty Page De votre climatiseur de pièce Table des matières 115V~ Avant dutiliser votre appareilAvertissement Mesures de SécuritéBords POINTUS! Les bords du cas peuvent être pointus Oscillation Automatique Fonctionnement de la télécommande CPCommande de l’orifice de ventilation Réglage de lorientation du débit dairRéglage de l’orientation du débit d’air Filtre à air Soins et entretienCaractéristiques particulières de l’appareil Installation du matérielPage Sans volets détanchéité Décalage To 11/4 Seuil Extérieur Installation de l’appareilDimensions de fenêtre minimales 27 à 16min. RebordContenu du nécessaire d’installation Préparation DU Cadre Outils recommandésSerrez pas. Fig Installation du boîtierAngle avant Cordon Dalimentation Vis Type a 1 Vis Type aÉtrier de verrouillage de fenêtre Installation sur le mur Instruction facultative Page Garantie limitée Climatiseurs Friedrich Model information can be found on the name plate located on CP LinesContenidos Provee buen flujo de aire IntroducciónAdvertencia Precaucion Precauciones de segoridadPrecaucion Funcionamiento del control remoto CP DosMed Ajustar la dirección del flujo de aire Control de ventilaciónAjustar la dirección del flujo de aire Cuidado y mantenimiento Filtro de Aire aDrenaje Funciones del producto Instalación de la unidadPage Saliente Cómo instalar la unidadRequisitos de la ventana 27 a Min asiento Con el marco de la cortinaContenidos de los conjuntos de instalación Preparación DEL Chasis Requisitos sugeridos de las ventanasInstalación del gabinete Tire cada marco de la cortina Al dintel 6 para equilibrar el gabineteColocando los tornillos 2 Tipo B Largo Ángulo frontal en el asiento de la ventanaAbrazadera de fijación Español Instrucciones de instalacion a traves de la pared opcional Español Garantia Limitada -PRIMER AÑO Friedrich AIR Conditioning CO
Related manuals
Manual 58 pages 2.08 Kb

CP10, CP12 specifications

The Friedrich CP10 and CP12 are advanced air conditioning units designed to provide optimal cooling and ventilation solutions for various applications. These models are particularly known for their innovative technologies and user-friendly features that prioritize efficiency and comfort.

One of the standout characteristics of both the CP10 and CP12 is their energy efficiency. They are equipped with advanced inverter technology, which allows the units to adjust their power output based on real-time cooling demands. This not only helps to reduce energy consumption but also minimizes noise levels, making these units ideal for residential and commercial settings alike.

The CP10 and CP12 feature a sleek and modern design, ensuring that they blend seamlessly into any environment. Their compact size makes them easy to install and suitable for a variety of spaces, from small rooms to larger commercial areas. Both models come with a built-in digital thermostat, allowing users to set and maintain their desired temperature with precision.

In terms of air filtration, the units are equipped with high-efficiency particulate air (HEPA) filters, which trap dust, allergens, and other airborne particles. This feature significantly improves indoor air quality, making the CP10 and CP12 perfect for users with respiratory issues or allergies. Furthermore, the filters are easily accessible, making maintenance simple and straightforward.

Connectivity is another key feature of the CP10 and CP12. They come with Wi-Fi capabilities, allowing users to control their air conditioning units remotely via a smartphone app. This convenience enables homeowners and business operators to adjust settings, track energy usage, and schedule operation times from anywhere.

Additionally, both models incorporate smart technology that enhances their usability. They can learn user preferences and automatically adjust cooling patterns to optimize comfort while ensuring energy savings. The intuitive user interface allows for easy navigation and customization, accommodating diverse user needs.

Durability is also a hallmark of the Friedrich CP10 and CP12. Constructed with high-quality materials, these units are designed to withstand various environmental conditions, ensuring longevity and reliable performance. The robust build quality minimizes the need for frequent repairs and maintenance, providing peace of mind for users.

In summary, the Friedrich CP10 and CP12 air conditioning units are exemplary models that embody energy efficiency, innovative technology, and user-friendly features. With their advanced cooling capabilities, superior air filtration, connectivity options, and robust design, they serve as ideal solutions for maintaining comfortable indoor environments in both residential and commercial spaces.