Bard Optional Accessories, WA301-A WA301-B WA301-C WA361-A WA361-B WA361-C

Page 19

TABLE 13

OPTIONAL ACCESSORIES

MODEL DESCRIPTION

WA301-A

WA301-B

WA301-C

WA361-A

WA361-B

WA361-C

EHWA03-A05

Heater Packages

1

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

EHWA03-A08

Heater Packages

1

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

EHWA03-A10

Heater Packages

1

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

EHWA03-A15

Heater Packages

1

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

EHWA03-B06

Heater Packages

1

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

EHWA03-B09

Heater Packages

1

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

EHWA03-B15

Heater Packages

1

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

EHWA03-C06

Heater Packages

1

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

EHWA03-C09

Heater Packages

1

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

EHWA03-C12

Heater Packages

1

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

EHWA03-C15

Heater Packages

1

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

BOP-3

Blank Off Plate

 

X

X

X

X

X

X

BFAD-3

Barometric Fresh Air Damper

X

X

X

X

X

X

 

 

 

 

 

 

 

 

MFAD-3

Motorized Fresh Air Damper

X

X

X

X

X

X

CRV-3

Commercial Ventilator with Exhaust

X

X

X

X

X

X

 

 

 

 

 

 

 

 

EIFM-3

Economizer with Exhaust

X

X

X

X

X

X

 

 

 

 

 

 

 

 

WERV-A3B

Energy Recovery Ventilator

X

X

 

X

X

 

 

 

 

 

 

 

 

 

WERV-C3B

Energy Recovery Ventilator

 

 

X

 

 

X

 

 

 

 

 

 

 

 

CMA-5

Time Delay Relay (TDR)

X

X

X

X

X

X

 

 

 

 

 

 

 

 

CMA-6

Low Ambient Control

X

X

 

X

X

 

 

 

 

 

 

 

 

 

 

CMA-8

TDR + HPC

 

X

X

X

X

X

X

 

 

 

 

 

 

 

 

 

CMA-10

LPC + HPC + TDR

 

X

X

X

X

X

X

 

 

 

 

 

 

 

 

CMA-13

LPC + HPC + TDR + LAC

X

X

 

X

X

 

 

 

 

 

 

 

 

 

 

CMC-15

Start Kit

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

WMCB-05A

Circuit Breaker Kit

 

X

 

 

X

 

 

 

 

 

 

 

 

 

 

 

WMCB-02B

Circuit Breaker Kit

 

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

WMPD-01C

Pull Disconnect Kit

 

 

 

X

 

 

X

 

 

 

 

 

 

 

 

 

WMCB-03B

Circuit Breaker Kit

 

 

 

 

 

X

 

 

 

 

 

 

 

 

 

 

Manual 2100-192 Page 17

Image 19
Contents Bryan, Ohio Installation Packaged Instructions AIR ConditionerWall Mounted Bard Manufacturing CompanyContents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsWall Mount General Information Electrical SpecificationsAIR Conditioner Wall Mount Model Nomenclature Front View Side View Back View Electric Heat Table Filters Shipping DamageGeneral Duct WorkFresh AIR Intake Fresh AIR Damper AssemblyCondensate Drain Mounting the Unit Installation InstructionsWiring Main Power Wall Mounting InformationWall Thermostat and Subbase Combinations Wiring LOW Voltage WiringThermostat Wire Size Operating Voltage RangeElectric Heat Clearance Mounting InstructionsWALL-MOUNTING Instructions Common WALL-MOUNTING Installations LOW Voltage Wiring Start UP Pressure Service Ports Refrigerant Charge TroubleshootingFAN Blade Setting Dimensions Removal of FAN ShroudMaximum ESP of Operation Electric Heat only Cooling Pressure Outdoor Temperature FWA301-A WA301-B WA301-C WA361-A WA361-B WA361-C Optional Accessories

WA301, WA361 specifications

The Bard WA361 and WA301 are two advanced wall-mounted air conditioning systems designed for commercial and residential use. These units are engineered to provide efficient cooling and heating while optimizing energy consumption.

One of the standout features of the Bard WA361 and WA301 models is their compact design. This allows for easy installation in various spaces where traditional floor-mounted units may not fit. Ideal for areas such as classrooms, offices, or small retail locations, these units can be mounted high on the wall, freeing up valuable floor space.

Both models leverage Bard’s advanced heat pump technology. This technology allows for reverse-cycle functionality, meaning they can provide both cooling in summer and heating in winter. The WA361 model offers a heating capacity of up to 36,000 BTUs while the WA301 provides a slightly lower capacity of 30,000 BTUs, making them suitable for different size requirements.

Energy efficiency is prioritized in these models. They come equipped with high Seasonal Energy Efficiency Ratings (SEER), which ensures lower electric bills and reduced environmental impact. Additionally, the units have been designed to operate quietly, maximizing comfort without the disruptive noise often associated with HVAC systems.

Another notable characteristic is the advanced control system. The Bard WA361 and WA301 feature programmable thermostats that allow users to set specific comfort levels according to their schedules. This not only enhances user control but also boosts energy-saving potential.

Moreover, both models are built with durable materials to ensure longevity and reliability. Their internal components are engineered to withstand harsh conditions, making them a preferred choice for various settings, including industrial environments.

Bard emphasizes ease of maintenance in the design of these units. The filters are easily accessible and can be replaced or cleaned with minimal effort. This feature significantly extends the lifespan of the unit and ensures that it operates at peak performance.

In summary, the Bard WA361 and WA301 air conditioning units represent a blend of innovative technology and practical design. Their energy-efficient operation, compact installation capability, and advanced heating and cooling functions make them exemplary solutions for those seeking reliable comfort control in diverse applications. Whether for small businesses or residential spaces, these units aim to deliver exceptional performance with a focus on sustainability and efficiency.