APC BR1000G Function Button Quick-Reference, Function Button Timing, Description, Seconds, Status

Page 6

Function Button Quick-Reference

Function

Button

Timing

UPS

Description

(seconds)

Status

 

 

 

 

 

Power

 

 

 

 

Power On

Power Off

0.2Off

2 On

Press POWER to start receiving input utility power. If A/C input power is not available, the Back-UPS will run on battery power.

The Back-UPS is not receiving input utility power, but is providing surge protection.

Display

Status Inquiry

Full-Time/Power- Saving mode

Mute

0.2On

2 On

Verify the status or condition of the Back-UPS. The LCD will illuminate for 60 seconds.

The LCD will illuminate and the Back-UPS will beep to confirm the Full-Time mode. The LCD will darken and the Back-UPS will beep to confirm the Power-Saving mode. While in Power-Saving Mode, the LCD will illuminate if a button is pressed, then darkens after 60 seconds of no activity.

Event Specific

0.2

On

General Status Enable/

2

On

Disable

 

 

Disable any audible alarms caused by an event.

Enable or disable the audible alarms. The Mute icon will illuminate and the Back-UPS will beep one time. The Mute function will not activate unless the Back-UPS is operating on battery power.

Sensitivity

6

Off

The Load Capacity icon will blink, indicating that the Back-UPS is

 

 

 

in programming mode. Use the POWER button to scroll through

 

 

 

Low, Medium, and High, stop at selected sensitivity. The Back-

 

 

 

UPS will beep to confirm selection. See Configuration for details.

 

 

 

 

Master/Controlled

2

On

The leaf icon will darken indicating that the Master Outlet feature is

outlet Enable/Disable

 

 

disabled or illuminate to indicate the Master Outlet feature is

 

 

 

enabled. The Back-UPS will beep once.

 

 

 

 

Master/Enable

6

On

While calibrating the threshold setting, the device connected to the

Threshold Calibration

 

 

Master Outlet should be turned off or placed in Standby or Sleep

 

 

 

mode. Upon completion, Power-Saving icon will flash 3 and beep

 

 

 

3 times.

 

 

 

 

Self-Test (manual)

6

On

The Back-UPS will perform a test of the internal battery. Note: This

 

will happen automatically when the Back-UPS is turned ON.

 

 

 

Event Reset

Fault Reset

0.2

On

When the Event screen is visible, press and hold DISPLAY, then

 

 

press POWER, to clear the utility failure event counter.

2

Fault

After a fault has been identified, press POWER to remove the

 

 

visual indication and return to standby status.

6

Back-UPS Pro 1000 Installation and Operation

Image 6
Contents InventorySafety Connect the batteryInstall PowerChute Personal Edition Software Battery Backup and Surge Protected outlets Connect the equipmentMaster and Controlled outlets Operation Power-Saving FunctionPower-Saving Display Unit sensitivityFront Panel Buttons and Display Interface Front panelAudible Warnings System FaultsIf these icons are This may be the problem Illuminated F01Description Function Button Quick-ReferenceFunction Button Timing SecondsTroubleshooting Problem Possible Cause Corrective ActionService SpecificationsReplacement Battery Warranty