Anton/Bauer T2 owner manual Three Stage Charging Methodology

Page 6

Three Stage Charging Methodology

In general, the TITAN T2 will deliver a three stage charge routine to each battery.

1.Stage One will deliver a high rate charge matched to the capabilities of the battery (typically a one or two hour rate, depending on battery type). During this stage, six separate cutoff methods are in operation, simultaneously, ensuring the fastest, safest charge for that battery:

TCO - Temperature cutoff which stops the Stage one charge precisely when a temperature indicative of full charge is reached;

Dt/dT - A microprocessor based algorithm which measures a rise in temperature over a specific time, very accurately indicating full charge. This method is also the recommended method for charging Ni-MH technology;

-ΔV- A method to determine the end of stage one charging by identifying a characteristic “reverse slope” of a Ni-Cd cell. Since this characteristic can be disguised by the age, temperature and the number of the cells in a battery, it can never be employed alone;

CCO - This method requires the identification of the particular battery size (capacity) and chemistry, an exclusive Anton/Bauer Logic Series feature. The charger determines the maximum charge time for the particular battery and uses this information to ensure that overcharge conditions are avoided.

FUL - This determination is made when a fully charged DIGITAL battery is returned to a charger within specified parameters of time, temperature, and battery voltage. The DIGITAL battery communicates its fully charged condition and the charger confirms the parameters and immediately indicates a fully charged condition, without additional verification.

TEMPERATURE COMPENSATED VCO – For HyTRON series of batteries. Optimizes VCO cutoff to operate only within certain temperature parameters.

In addition, a voltage limiting constant current Stage One routine address the critical parameters of DIONIC batteries.

2.Stage Two charging is a BALANCING or “stabilizing” mode which calculates each battery pack type to offset any imbalance of the battery’s cells, created by unequal self discharge or any capacity mismatch of the individual cells in the pack. This stage can vary in duration from zero to as much as 16 hours, depending on the condition of the battery. The Stage Two charge for DIONIC batteries reduces current automatically as the battery charges maintaining the lithium ion cells at a safe voltage level. A battery will typically leave Stage Two in 2-4 hours under average operating conditions.

3.Stage Three charging is the Anton/Bauer exclusive Lifesaver maintenance mode. This patented pulse routine keeps batteries fully charged, free from self- discharge - indefinitely - without damaging heat associated with a so-called “trickle charge”. The Stage Three programming for DIONIC monitors the self discharge of the battery, providing charge only when the battery self discharges to about 95% of its capacity.

4

Image 6
Contents Titan T2 Operation AS DC Camera Supply from Mains Features IntroductionSafeguards GROUNDING/EARTHINGCharging ApplicationsThree Stage Charging Methodology LED Indications LED Indication MeaningOperation AS DC Camera Supply from Mains Specifications FUSE/TYPE ReplacementFCC Notice Warranty Worldwide standard→

T2 specifications

The Anton/Bauer T2 is a cutting-edge battery system designed for professionals in the film, television, and broadcasting industries. Renowned for its reliability and high performance, the T2 represents the next generation in portable power solutions, catering to the demands of modern cinematography.

One of the standout features of the T2 is its unique lithium-ion battery technology. This advanced system offers longer run times and quicker recharge cycles compared to traditional battery technologies. With a high-capacity 98Wh or 150Wh option, the T2 enables users to power a wide range of devices, from lightweight cameras to more demanding equipment. The intelligent design of the T2 allows it to maintain a consistent voltage output throughout its discharge cycle, ensuring that devices operate at optimal performance until the battery is depleted.

Durability is a hallmark of the T2. Built to withstand the rigors of production environments, the battery features robust construction with an integrated shock-absorbing frame. This makes it resistant to drops and impacts, a critical attribute for on-location shooting. Additionally, the T2 is equipped with a smart battery management system that provides real-time diagnostics, including remaining power, cycle count, and overall health, enabling users to make informed decisions about battery usage.

Another significant technology embedded in the T2 is its compatibility with Anton/Bauer's series of chargers and accessories. This seamless integration allows for quick and easy charging, ensuring that professionals can always have power on hand. The T2 also features built-in DC ports, facilitating direct connections to various camera systems and lighting, further enhancing workflow efficiency.

The form factor of the T2 has been thoughtfully designed to fit snugly onto cameras and equipment without adding unnecessary bulk. The ergonomic design includes a lightweight construction that ensures ease of handling and transport. Furthermore, the battery's design incorporates an intuitive LED status gauge, providing instant feedback on charge levels.

In summary, the Anton/Bauer T2 is a state-of-the-art battery solution that embodies advanced technology, durability, and user-friendly features. Its lithium-ion technology, robust construction, smart battery management, and compatibility with existing Anton/Bauer products make it an essential tool for professionals seeking reliable power for their shooting needs. With the T2, filmmakers can confidently focus on their craft, knowing that their equipment is powered by a dependable source.