Belkin BU3DC001-12V user manual Audible and Visual Alarms

Page 7

Audible and Visual Alarms

The RG Battery Backup alarms to indicate certain events.

Front-Panel

Visual

Audible

Description

Label

Indicator

Alarm

 

 

 

 

 

On A/C

Green LED

None

The RG Battery Backup is

 

lights

 

operating on A/C.

 

 

 

 

Testing

Green LED

None

The RG Battery Backup is conduct-

Battery

flashes

 

ing a self-test. This procedure is

 

 

 

normal and will occur when the

 

 

 

self-test is manually initiated and

 

 

 

periodically thereafter (see page 8).

 

 

 

This procedure will last

 

 

 

approximately 5 minutes.

 

 

 

 

On

Yellow LED

Tone every

The RG Battery Backup is

Battery

lights

10 seconds

operating on battery power.

 

 

 

The alarm will stop when the A/C

 

 

 

power is restored.

 

 

 

 

Low

Yellow LED

Tone every

The battery energy is running low.

Battery

flashes

1 second

This alarm will continue until the

 

 

 

unit performs a forced shutdown

 

 

 

when the battery is depleted or A/C

 

 

 

power is restored.

 

 

 

 

Replace

Red LED

Tone every

The battery may have reached the

Battery

flashes

5 seconds

end of its useful life. Conduct a self

 

 

 

test (see page 8). If the alarm

 

 

 

remains on, replace the battery as

 

 

 

soon as possible to ensure proper

 

 

 

operation of the RG Battery Backup

 

 

 

(see page 9).

 

 

 

 

Fault

Red LED

Continuous

A fault has occurred. Reset the RG

 

lights

tone

Battery Backup (the unit) by:

 

 

 

* Turn off the unit

 

 

 

* Disconnect unit from the AC outlet

 

 

 

* Reconnect unit to the AC outlet

 

 

 

* Turn on the unit

 

 

 

If the fault is not corrected, turn off

 

 

 

the unit and disconnect from the AC

 

 

 

outlet prior to checking Residential

 

 

 

Gateway. If fault persists, contact

 

 

 

Belkin for assistance.

 

 

 

 

NOTE: Audible alarm will not sound when mute switch is in ON position.

6

Image 7
Contents REV B Table of Contents Introduction Safety InformationSystem Requirements Recycling Package ContentsMute on/off ControlsandStatusIndicatorsPower on/off Status IndicatorsREV B RG Battery Backup alarms to indicate certain events Audible and Visual AlarmsConnect to the Residential Gateway InstallationConnect to AC Utility Power Turning on the RG Battery BackupTo Conduct a Self-Test Turning off the RG Battery BackupTo Silence Audible Alarm OperationNo tools are needed Battery Replacement ProcedureLimited Three 3 Year Warranty WarrantyTechnical Specifications Technical SpecificationsBattery @ 77 degrees F, 25 degrees C