TEMPERATURE COMPENSATION

MULTI XS 25000, XS 25000, MULTI XT 14000 and XT 14000 have a sensor cable placed together with the battery cables. The units will automatically adjust the charging voltage if the temperature deviates from +25 C. A high temperature lowers the voltage and freezing conditions is handled by higher voltage.

The temperature is best measured on or very close to the battery. Therefore always place the sensor as close to the battery as possible when charging. The sensor cable could be prolonged or cut to length with the same functionality. A short-circuited or disconnected sensor is indicated by lamp A. The charging voltage is then adjusted to the +25 C condition.

SPECIFICATION

 

MULTI XS 25000

 

MULTI XT 14000

 

XS 25000

 

XT 14000

Voltage AC

170-260 VAC, 50-60 Hz.

 

 

 

 

Charging voltage

14.4 V

 

28.8 V

 

 

 

 

Charging current

25 A max.

 

14 A max.

 

 

 

Current, mains

2,9 A rms (at full charging current)

 

 

Back Current Drain*

<2Ah per month

 

 

 

Current ripple**

 

<4 %

 

 

Ambient temperature

- 20°C to + 50°C Output power is automatically reduced at higher temperatures.

 

 

 

Cooling

 

Fan

 

 

Charger type

Eight-step, fully automatic

 

 

 

 

Battery types

All types of 12 V lead-acid batteries

 

All types of 24 V lead-acid batteries

 

(WET, MF, AGM and GEL).

 

(WET, MF, AGM and GEL).

Battery capacity

40-500Ah

 

28-300Ah

 

 

 

up to 500 Ah maintenance

Protection class

IP 44 (Outdoor use)***

 

 

 

Weight

 

1,4 kg

 

 

 

 

*) Back current drain is the current that the charger drains from the battery if the AC cord is disconnected.

**) The quality of the charging voltage and charging current are very important. High current ripple heats the battery and ages the positive electrode. High voltage ripple can damage other equipment connected to batteries. The battery chargers from CTEK produces very high quality voltage and current with low ripple.

***) IP 44 cannot be guaranteed if the charger is not positioned horizontally with the long side or top side turned up.

5

Image 5
Contents Battery Charger Connecting the charger to a battery fitted in a vehicle Introduction SafetyConnecting the charger to an out of vehicle battery ChargingCharging Phases Battery Types and SettingsLamp Description IndicatorsFault mode Specification Temperature CompensationVolts Amperes Voltage Preset YESCurrent Desulphation Soft Start Bulk AbsorptionAnalysis Recond Float Pulse Utes only in Recond ModeAnalysis Recond Float Limited Warranty MaintenanceDeclaration of Conformity Ctek Sweden AB