PARAMETERS

PROGRAM DESCRIPTION

 

 

Desulphation

Soft Start

Bulk

Absorption

 

(Volts)

 

 

 

 

(Amperes)

Voltage

Recovers a

Tests the battery

Bulk charge

Peak charge with

sulphated battery

condition

minimal fluid loss

 

 

 

 

 

Current

 

 

 

 

 

MULTI XS 25000

MODE

Desulphation

Soft Start

Bulk

Absorption

NORMAL

YES

Max 10 A for 4 h until the

25 A for max 20 h.

14.4 V until 4 h after the

or

 

voltage reaches 12 V.

 

current dropped to 3 A,

RECOND

 

 

 

max 12 h.

 

 

 

 

 

SUPPLY

 

 

 

 

XS 25000

 

 

 

MODE

Desulphation

Soft Start

Bulk

Absorption

PRESET

YES

Max 10 A for 4 h until the

25 A for max 20 h.

14.4 V until 4 h after the

 

 

voltage reaches 12 V.

 

current dropped to 3 A,

 

 

 

 

max 12 h.

MULTI XT 14000

 

 

 

MODE

Desulphation

Soft Start

Bulk

Absorption

NORMAL

YES

Max 6 A for 4 h until the

14 A for max 20 h.

28.8 V until 4 h after the

or

 

voltage reaches 24 V.

 

current dropped to 2 A,

RECOND

 

 

 

max 12 h.

 

 

 

 

 

SUPPLY

 

 

 

 

XT 14000

 

 

 

MODE

Desulphation

Soft Start

Bulk

Absorption

PRESET

YES

Max 6 A for 4 h until the

14 A for max 20 h.

28.8 V until 4 h after the

 

 

voltage reaches 24 V.

 

current dropped to 2 A,

 

 

 

 

max 12 h.

6

Image 6
Contents Battery Charger Connecting the charger to an out of vehicle battery Introduction SafetyConnecting the charger to a battery fitted in a vehicle ChargingBattery Types and Settings Charging PhasesIndicators Fault modeLamp Description Temperature Compensation SpecificationCurrent Preset YESVolts Amperes Voltage Desulphation Soft Start Bulk AbsorptionUtes only in Recond Mode Analysis Recond FloatAnalysis Recond Float Pulse Declaration of Conformity MaintenanceLimited Warranty Ctek Sweden AB