Operation (continued)

“OPERATION” Indicator Lights

“LINE” Green Indicator: If the operating mode switch is set to “AUTO”, this light will illuminate continuously while connected equipment is receiving continuous AC power from a utility/generator source. If the operating mode switch is set to “CHARGE ONLY”, this light will flash to alert you that the unit's inverter is disabled and will not supply AC power when utility/generator power is unavailable or unsafe for connected equipment.

“INV” (Inverting) Yellow Indicator: This light will illuminate continuously while connected equipment is receiving battery-supplied, inverted AC power when utility/generator power is unavailable or unsafe for connected equipment.

“LOAD” Red Indicator: This red light will flash if the power demanded by connected appliances and equipment exceeds load capacity while the Inverter/Charger is operating from battery power. It will also flash due to inverter overheating. If this happens, turn the operating mode switch to “DC OFF”, remove the overload and allow the inverter to cool. After the unit has adequately cooled, you may turn the operating mode switch to either “AUTO” or “CHARGE ONLY”.

“BATTERY” Indicator Lights

These three lights will illuminate in several sequences to show the approximate charge level of your connected battery bank and alert you to fault conditions:

Battery Charge Level*

 

Indicator Illuminated

Battery Capacity

 

 

 

 

 

(Charging/Discharging)

 

 

 

1

Green

~ 91%–Full

 

 

 

2

Green & Yellow

~ 81%–90%

 

 

 

3

Yellow

~ 61%–80%

1

2

3

4

Yellow & Red

~ 41%–60%

 

 

 

5

Red

~ 21%–40%

 

 

 

6

All three lights off

~ 1%–20%

 

 

 

7

Flashing red

~ 0% (Inverter shutdown)

4

5

6

 

 

 

* Charge levels are approximate.

 

 

 

 

Actual levels vary depending on battery condition and load.

 

 

 

Fault Condition

 

7

 

 

 

 

 

 

 

Indicator Illuminated

Fault Condition

 

 

 

1

All three lights flash quickly*

Overcharge (Charger shutdown)

 

 

 

* Approximately ¼ second on, ¼ second off. May also indicate a battery

 

 

 

charger fault exists. See the Troubleshooting section.

 

 

 

Resetting Your Inverter/Charger to Restore AC Power

 

 

1

 

 

 

Your Inverter/Charger may cease to supply AC power or DC charging power in order to protect itself from overload or to protect your electrical system. To restore normal functioning:

Overload Reset: Switch the operating mode switch to “DC OFF” and remove some of the connected electrical load (i.e. turn off some of the AC devices drawing power which may have caused the overload of the unit). Wait one minute, then switch the operating mode switch to either “AUTO” or “CHARGE ONLY”.

Output Circuit Breaker Reset: Alternatively, check the unit's output circuit breaker. If it has tripped, remove some of the electrical load, wait one minute to allow components to cool, and reset the circuit breaker. See the Troubleshooting section for other reasons why AC output may be absent.

8

Image 8
Contents Contents DC-to-AC Inverter/ChargerImportant Safety Instructions Battery Connection WarningsLocation Warnings Equipment Connection WarningsFeatures Battery Selection Match Battery Amp-Hour Capacity to Your ApplicationMounting Battery Connection Battery ConfigurationOperation Switch ModesAC Connection Resetting Your Inverter/Charger to Restore AC Power Operation Indicator LightsBattery Indicator Lights Troubleshooting Operation Indicator LightsSpecifications Battery WiringLimited Warranty ServiceMaintenance Th Street, Chicago, IL 60609 USA