Return Tube Kit
Return Tube Kit
The Return Tube Kit can be installed singly or as a pair. Two are included in the Circulation Kit, page 3.
1.Keep A and B compo- nents separate
CAUTION
To prevent
2.Assemble return tube kit
Remove dryer carriage (C). Using awl or similar tool, punch a few small holes in each end of car- riage. Reinstall carriage.
Remove large fitting included with dryer (10). It is not needed for this application.
Apply thread sealant (8) to threads. Assemble return tube kit as shown at right.
3.Install kit in drum
Open drum port. Lower kit into drum. Screw tee
(6) into drum port to secure. Use bushing (5) to adjust position of tube (4) in tank.
4.Install circulation kit, page 3
WARNING
To reduce the risk of serious injury including fluid injection, use high pressure return hoses rated to with- stand the maximum working pressure of the propor- tioner. See proportioner operation manual.
|
| Return Tube Kit |
| |
|
|
|
| Qty |
Ref. |
| (CS) | (SST) | |
|
| |||
No. | Description | 246477 | 24D106 |
|
|
|
|
|
|
1 | ELBOW, 90°; 1/2 in. (13 | 117532 | 16C635 | 1 |
| mm) OD tube x 1/2 npt(m) |
|
|
|
2 | FERRULE, tube; sst | 117453 | 117453 | 1 |
3 | NUT, tube, flareless | 117454 | 16C636 | 1 |
4 | TUBE; sst; 1/2 in. (13 mm) | 15C514 | 15C514 | 1 |
| OD; 4 ft (1.2 m) |
|
|
|
5 | BUSHING, strain relief; 3/4 | 117811 | 117811 | 1 |
| npt(m) |
|
|
|
6 | TEE, street; 3/4 npt (mxf) | 111337 | 16C637 | 1 |
| run; 3/4 npt(f) branch |
|
|
|
8 | SEALANT, pipe; 6 ml | 110110 | 110110 | 1 |
10 | KIT, accessory, desiccant | 247616 | 247616 | 1 |
| dryer |
|
|
|