Harbor Freight Tools 93271 Figure B, To Adjust The Air Output To The Pneumatic Tool

Page 6

2.Pull on the Pressure Relief Valve (5A) briefly to ensure that it does not stick.

3.Turn the Air Flow Valve (6A) to its “OFF” position.

3.Connect the air hose (not provided) to the Air Flow Valve (6A) of the Air Compres- sor. Then, connect the other end of the air hose to the pneumatic tool (not provided) that is to be used.

4.To extend the life of your air tools and equipment, it is recommended to install an oiler and water filter in series (available from Harbor Freight Tools) with the Air Output Line of the Air Compressor. (See Figure B.)

AIR

COMPRESSOR

TO

TOOL

FIGURE B

5.Note: Always plug the Power Cord of the Air Compressor into a 230V electri- cal source.

6.Pull up on the “ON/OFF” Power Switch (1A) to turn the Air Compressor on. (Push down on the “ON/OFF” Power Switch to turn the Air Compressor off.)

7.Allow sufficient time for the Tank Pressure Gauge (4A) to indicate 80 PSI before using the Air Compressor.

8.Turn the Air Flow Valve (6A) to its “ON” position to allow air to the pneumatic tool.

9.With the Air Compressor turned on, the operation is automatic and under the control of the automatic switches inside the box under the Power Switch (1A).

NEVER open the power switch box or adjust the controls within.

To Adjust The Air Output To The Pneumatic Tool:

1.NOTE: When adjusting the air pressure being forwarded to the pneumatic tool, you will need to compare the pressure readings of both the Tank Pressure Gauge (3A) and the Tool Pressure Gauge (4A). The reading on the Tank Pressure Gauge dic- tates the maximum/minimum air pressure at which the Tool Pressure Gauge may also be set.

2.With the Air Compressor running, and the air hose and pneumatic tool hooked up to the Air Compressor, pull up on the Tool Pressure Adjuster (2A). Turn the Tool Pres-

SKU 93271

For technical questions, please call 1-800-444-3353.

PAGE 6

Image 6
Contents GALLON, 230 VAC Specifications General Safety Warnings and PrecautionsSave this Manual Industrial Applications Must Follow Osha Requirements Specific Product Warnings and Precautions To Check The Oil Level UnpackingOperating Instructions To Turn The Air Compressor OnTo Adjust The Air Output To The Pneumatic Tool Figure BTo Use The Tank Pressure Relief Valve To Empty Moisture From The TankINSPECTION, MAINTENANCE, and Cleaning Do not use damaged equipmentParts List a / Assembly Diagram Part Description QtyParts List B / Assembly Diagram B
Related manuals