Harbor Freight Tools 47065 To Turn The Air Compressor On, See Assy. Diagram a

Page 6

2.If necessary, add a premium quality, 30-weight, non-detergent oil into the Oil Fill Hole until the level of oil reaches the maximum level as indicated on the Oil Window (20B). The optimal capacity of the oil reservoir is 30 ounces. Do not overfill. Then thread the Dip Stick back into the Oil Fill Hole, being careful not to

strip the plastic threads. (See Figure C, and Assy. Diagram B.)

Dip Stick (14B)

Front Cover (18B)

Oil Window (20B)

FIGURE C

To Turn The Air Compressor On:

1.Check to make sure the Water Drain Valve (10A) is fully closed.

(See Assy. Diagram A.)

2.Turn the Air Flow Valve (6A) to its “OFF” position. (See Assy. Diagram A.)

3.Connect the air hose (not provided) to the Air Flow Valve (6A) of the Air Com- pressor. Then, connect the other end of the air hose to the pneumatic tool (not provided) that is to be used. (See Assy. Diagram A.)

4.Note: Always plug the Power Cord of the Air Compressor into a 115V elec- trical source (±10% maximum variation).

5.Pull up on the “ON/OFF” Power Switch (1A) to turn the Air Compressor on. (Push down on the “ON/OFF” Power Switch to turn the Air Compressor off.)

(See Assy. Diagram A.)

6.Allow sufficient time for the Tank Pressure Gauge (4A) to indicate 80 PSI before using the Air Compressor. (See Assy. Diagram A.)

7.Turn the Air Flow Valve (6A) to its “ON” position to allow air to the pneumatic tool.

(See Assy. Diagram A.)

REV 11/04

SKU 47065

For technical questions, please call 1-800-444-3353.

PAGE 6

Image 6
Contents Gallon For technical questions, please callSpecifications Table General Safety Warnings and PrecautionsSave this Manual Industrial Applications Must Follow Osha Requirement Specific Product Warnings and Precautions Operating Instructions Diagrams on pages 10,Unpacking To Check The Oil LevelSee Assy. Diagram a To Turn The Air Compressor OnTo Use The Tank Pressure Relief Valve To Adjust The Air Output To The Pneumatic ToolDiagram a To Empty Air And Condensation From The TankINSPECTION, MAINTENANCE, and Cleaning Reference Overload Switch #35BDo not use damaged equipment Parts List a / Assembly Diagram Part Description QtyParts List B / Assembly Diagram B Part Description Qty