WIRING DIAGRAM: SYSTEM USED FOR SELECTIVE DOOR RELEASE
LDF-20C
1
2
3
~
20
E
-
LE-D
1 | |||
1 | |||
| |||
| 1 | ||
|
| ||
E | E | E | |
- | - | - |
To activate door release, press button located above TALK button.
1
2
3
~
20 L
BLK
YEL |
|
|
| Momentary Closure for Station #1 | |
|
|
|
| ||
#1 |
|
|
| Momentary Closure for Station #2 | |
| BLK | YEL |
| ||
|
|
| |||
|
| #2 |
|
| Momentary Closure for Station #3 |
|
|
|
| ||
|
|
| BLK | YEL | |
|
|
|
| #3 |
|
|
|
|
|
| Common for each closure |
Normally Open contacts are maintained when the door release button is being pressed while a station button is selected.
|
| |||
|
|
| + | |
| + |
| ||
| ||||
| - |
|
| - |
|
| |||
|
|
|
|
|
External | To convert |
|
Terminal Block | x x | |
| (normally closed) contact: | |
| Move one yellow wire | AC Power |
| from "NO" to "NC". | |
| for Door | |
| (Internal modification, | Releases |
| soldering required.) |
|
OPERATION:
*POWER SWITCH MUST BE ON FOR SYSTEM TO BE OPERABLE.
1.When a station calls in, press the selector button corresponding to the lit LED.
2.To speak to the person at the remote station, press the TALK button (or pick up the handset). Release TALK button to hear reply. Communication via the handset is VOX (voice actuated).
3.If the extra contacts are used as shown in the "camera
4.If the extra contacts are used as shown in the "selective door release" diagram, press the "door release" button while the selector button is depressed. This will activate the corresponding relay as long as the button is
being | held, which will activate the door release mechanism. |
5.If both functions are used on a channel, the device connected to the "constant closure" relay will be on for the duration of the call. The "momentary closure" will only be active when the door release button is pressed.
6.When the conversation is completed, press the OFF button to the left of the station selector button. Hang up handset.
SPECIFICATIONS |
|
|
| For additional information about this system, | |||
|
|
| please refer to the | ||||
Power Source: | 12V DC at master. Use | ||||||
|
|
| |||||
Commun. Output: | 800mW at 20 ohms |
|
|
|
| ||
|
|
|
| ||||
Communication: |
|
| |||||
| Hands free at sub station. |
|
|
| |||
Calling: | Master to sub: | By voice only |
|
|
| ||
| Sub to master: Call button on sub activates tone and LED at master. |
|
| ||||
|
| LED remains lit for 20 seconds, and tone is momentary. |
|
| |||
Wiring: | 2 conductors homerun to sub station |
|
| ||||
| or loop |
|
| ||||
| Separate 2 conductor from |
|
| ||||
| Shielded cable is recommended. |
|
|
| |||
| Use Aiphone #822202 (2 cond., 22AWG) or #822203 (3 cond., 22AWG) wire. |
|
| ||||
Wiring Distance: | 650' with 22AWG; 1,600' with 18AWG. |
|
|
| |||
Aiphone Communication Systems | TOLL FREE TECHNICAL SUPPORT: |
|
| ||||
1700 130th Ave. N.E. |
| (800) |
|
|
|
| |
Bellevue, WA 98005 |
| TOLL FREE FAX LINE: |
| Pg. 2 | |||
(425) |
| (800) |
|
| LDF Instr. | ||
FAX (425) |
| 1103BKJS |