Harbor Freight Tools 45885 operating instructions Maintenance

Page 8

Spindle

Lock

Fixed Shield (10)

 

Button

 

(32)

Lock Bolt (19)

 

Screw (71)

7.Remove the existing Saw Blade and replace with another 10 inch blade.

The new Saw Blade has an arrow on it that must be pointing in the same direction as the large arrow on the outside of the Fixed Shield (10).

Caution: Never use saw blades larger or smaller in diameter than 10 inches, and rated less than 5000 RPM operation.

8.Replace the Saw Blade Press Plates and Lock Bolt.

9.Press in on the Spindle Lock button and retighten the Bolt in a counterclockwise direction.

10.Replace the safety Shield to its original position and retighten the Screws.

11.Press down on the saw Handle and verify that the safety Shield moves back properly, and that the blade does not touch the Fence or Table.

Maintenance

Replacing the Motor Brushes

It may become necessary at sometime to replace the motor brushes when the motor per- formance decreases, or stops working completely. The following steps describe their re- placement. This procedure should be done by a qualified technician.

1.Unplug the Power Cord Plug from the electrical outlet.

2.Remove the Screws (51) and Cover (52) from the Field Case (43).

Field Case (43)

Screws (51)

SKU 45885

Page 8

REV 05/03

45885.p65

8

10/15/03, 10:41 AM