Curtis 1620S manual Installation

Page 10

3

 

INSTALLATION

3.1

Unit should be securely mounted to a flat surface.

3.2

The power cord to the IEC 320/C14 connector should be of the appropriate

 

gauge to carry a 15A current, for the cable’s length, to meet the requirements

 

of applicable electrical codes. The power cord must meet IEC requirements

 

with a minimum cross section of 1.5mm.

3.3

The wires between the charger output and the battery should be of the

 

 

appropriate gauge to carry a 20A current, for the cable’s length, to meet the

 

 

requirements of applicable electrical codes. An inline fuse (32V min. 30A

 

 

max.) is recommended to protect against accidental battery short circuit.

 

3.4

A minimum of 30mm clearance should be provided at each vented end of

 

 

the charger.

 

3.5

Charger should not be installed in locations which restrict airflow to the

 

 

unit.

 

3.6

The circuit supplying power to the charger should be rated at a minimum of

 

 

15A for a 120VAC circuit, or for 5A for a 230VAC circuit.

page 17

Curtis 1620 Manual

Image 10
Contents Manual Important Safety Instructions WarrantyContents Technical Specifications Model EncodementCompliance Battery TypesEnvironmental Charge Cycle ProfileEnd of Charge Mode Charge profile for End of Charge ModeEqualize Mode after End of Charge Mode Charge profile for Equalize ModeFloat Mode Charge profile for Float ModeFlash Pattern Mode Charge Status Indication LightsInstallation Plug the charger into an appropriate AC power source Appropriate connector on the motor speed controllerOperation This manual Troubleshooting5s on, 0.5s off Maintenance Replacing the fanProgramming Parameters TcmaxVoltage is greater than or equal to Vuvlo, and less than Vlv Curtis INSTRUMENTS, INC