2.7.2- Equalize Mode after End of Charge Mode

Figure 2. Charge profile for Equalize Mode

Figure 2 defines the charge profile for the Equalize Mode. After going through bulk charge and Constant Voltage modes, the charger will reduce its output cur- rent to Top-Off Current (Ito) until one of the two possible outcomes occurs:

(1)Battery voltage rises to Equalize Voltage (Vequ) or

(2)Equalize Time-Out (Tto) is reached.

Once one of these two possibilities occur, charging will stop and the 1620 will set itself to Off Mode; the charger remains in standby until restart voltage (Vrst) is reached.

Curtis 1620 Manual

page 4

Image 7
Contents Manual Warranty Important Safety InstructionsContents Model Encodement Technical SpecificationsCharge Cycle Profile Battery TypesEnvironmental ComplianceCharge profile for End of Charge Mode End of Charge ModeCharge profile for Equalize Mode Equalize Mode after End of Charge ModeCharge profile for Float Mode Float ModeIndication Lights Flash Pattern Mode Charge StatusInstallation Plug the charger into an appropriate AC power source Appropriate connector on the motor speed controllerOperation This manual Troubleshooting5s on, 0.5s off Replacing the fan MaintenanceTcmax Programming ParametersVoltage is greater than or equal to Vuvlo, and less than Vlv Curtis INSTRUMENTS, INC