Bryant A07045, A07044 installation instructions Single-Stage Furnace w/Heat Pump

Page 71

Thermostat

 

 

 

 

 

 

RVS/Heat Stage 2

O/B W2

 

 

 

 

 

 

 

Heat Stage 1

W/W1

 

 

 

 

 

 

 

Compressor Low

Y1

 

 

 

 

 

 

 

Compressor High

Y/Y2

 

 

 

 

 

 

 

Fan

G

 

 

 

 

 

 

 

24VAC Hot Heating

Rh

 

 

 

 

 

 

 

24VAC Hot Cooling

Rc

 

 

 

 

 

 

 

Dry Contact 1

 

 

D1

 

 

 

 

 

 

 

Dry Contact 2

 

 

D2

 

 

 

 

 

 

 

24VAC Common

C

 

 

 

 

 

 

 

Humidify

HUM

 

 

 

 

 

 

 

Outdoor Air Temp

OAT

 

 

 

 

 

 

 

Remote Room Sensor

RRS

 

 

 

 

 

 

 

OAT/RRS Com

OAT/RRS

 

 

 

 

 

 

 

Single-Stage

Furnace

W

Y

G

R

DEHUM

COM

Humidifier Solenoid

Valve *

Outdoor Sensor *

Remote Room

Sensor *

Single-Stage

Heat Pump

O

 

W2

*

Y

 

R

 

COM

 

A006585

Fig. 30 - Single-Stage Furnace w/Heat Pump

*Indicates connection may not be required/available.

71

Image 71
Contents Installation Instructions Safety Considerations Table of ContentsIntroduction Power Installation ConsiderationsHumidify Equipment and Connections ModelsDehumidify Equipment and Connections Outdoor Temperature SensorTwo-Piece Thermidistat Configuration Remote Indoor Temperature SensorT6-PRH Carton Contents InstallationThermidistat Control Location T6-NRH Carton ContentsInstall Thermidistat Control Unit Damage Hazard Environmental Hazard Two-Piece InstallationPress Tabs to Remove Backplate Backplate Mounting Relays Secure Wires to Terminal Strip Attach Display to Backplate Equipment Control Module on Equipment Standoff Cover on Equipment Control Module Single-Piece Installation Equipment Control Module Reattach Display Module Set Thermidistat Control Configuration Page Option 01 Equipment Type Configuration Options -SelectionOption 04 Fan G On With W/W1 Option 02 Clean Filter TimerOption 03 Fahrenheit/Centigrade Option 07 Zoning Option 08 Auxiliary Heat Lockout TemperatureOption 06 Cooling Lockout Below 55F Option 10 Reversing Valve Option 09 Heat Pump Lockout TemperatureOption 14 Humidity Display Offset Adjust Option 11 Deadband Setting Between Heat & CoolOption 12 Smart Recovery Option 13 Room Air Temperature Offset AdjustOption 17 Time Between Equipment Stages Option 16 Maximum Cycles Per HourOption 19 Dry Contact Configuration programmable models only Option 18 Backlight ConfigurationOption 21 Keypad Lockout programmable models only Option 20 Outdoor Air Temperature Offset AdjustmentOption 21 Keypad Lockout non-programmable models only Option 23 High Heat Latch Temperature Option 22 High Cool Latch TemperatureOption 26 Minimum Cooling Setpoint Option 29 Humidifier Pad Reminder Option 27 Maximum Heating SetpointOption 28 UV Light Reminder Option 30 Programmable Fan programmable models only Option 99 Reset to Factory Defaults Option 33 Single or Two-Piece InstallationSystem START-UP and Checkout To Test FAN Final SettingsEnergy Star Default Schedule Humidification Humidity Control FeaturesTo Select Humidification programmable Humidification SelectionsAdditional Humidify Comments DehumidificationTo Select Humidification non-programmable Page Auto Humidity Dehumidify Output and Equipment Connections Additional Dehumidify CommentsVacation programmable models only Vacation Dehumidification Vacation Setpoints Default ValuesVacation Setpoints Vacation HumidificationOperational Information TimersThree-Minute Minimum on Time Equipment On IndicatorsHeat/Cool Setpoints Desired Temperature Programmable Fan programmable models only Humidify and Dehumidify IndicatorsEmergency Heat Mode Auto ChangeoverError Codes TroubleshootingPage Equipment Cool Heat Equipment Configuration OutputsTwo-stage Hybrid Heat W2/B Display to Equipment Control Module Connection Wiring DiagramsFV/FK Fan Coil w/2-Stage Heat Pump Typical Fan Coil w/Heat Pump A06575 FV/FK Fan Coil w/2-Stage Air Conditioner Typical Fan Coil w/Air Conditioner A06578 FV/FK Fan Coil w/1-Stage Heat Pump Typical Fan Coil Heating Only Thermidistat Control w/Dry Contact Control for Fan Run Time FV/FK Fan Coil w/1-Stage Air Conditioner Typical Fan Coil Cooling Only Variable Speed/Multi-Stage Furnace w/2-Stage Heat Pump Single-Stage Furnace w/Heat Pump Variable Speed/Multi-Stage Furnace w/2-Stage Air Conditioner Single-Stage Furnace w/Air Conditioner Variable Speed/Multi-Stage Furnace w/Single-Stage Heat Pump Single-Stage Furnace Heating Only A06590 Single-stage Furnace with Air Conditioner and Split Power Mode Settings Thermidistat Configuration RecordConfiguration Options Catalog No IIT6---PRH---02

A07045, A07044 specifications

Bryant A07044 and A07045 are two advanced air conditioning units designed for both residential and commercial applications. These models are specifically engineered to provide high-efficiency cooling and optimal indoor comfort. With a focus on innovative technologies, they deliver reliability and performance that meet the demands of today's energy-conscious consumers.

One of the standout features of the Bryant A07044 and A07045 is their impressive Energy Efficiency Ratio (EER). Both models are designed to consume less energy while providing substantial cooling power, which not only reduces utility bills but also contributes to a more sustainable environment. Their high-efficiency refrigerant systems ensure optimal performance even in extreme weather conditions.

Both models incorporate advanced inverter technology, which enables them to modulate cooling output based on the specific needs of the space. This allows for quieter operation and improved temperature control, ensuring that every room is maintained at the desired comfort level without unnecessary energy consumption. The variable-speed compressor adjusts the cooling output, providing more precise temperature regulation.

In terms of installation and integration, both Bryant A07044 and A07045 feature a compact design that makes them ideal for various spaces, whether it's a small apartment, a large commercial space, or anything in between. Their lightweight construction and flexible mounting options simplify the installation process, saving time and labor costs.

User-friendly controls are another significant feature of these models. They come equipped with a digital thermostat that allows homeowners and facility managers to easily program their desired temperatures. Additionally, many Bryant air conditioning units are compatible with smart home systems, enabling remote access and monitoring for added convenience.

Durability is a hallmark of Bryant's engineering, and both the A07044 and A07045 exemplify this commitment. They are constructed with high-quality materials and corrosion-resistant components, ensuring that they can withstand harsh environmental conditions. This longevity is complemented by Bryant's extensive warranty offerings, providing peace of mind for consumers.

In summary, the Bryant A07044 and A07045 air conditioning units stand out for their energy efficiency, advanced inverter technology, user-friendly controls, and robust construction. They are excellent choices for anyone seeking reliable and efficient cooling solutions for their homes or businesses.