Bryant A07044, A07045 installation instructions Catalog No IIT6---PRH---02

Page 80

E. Configuration Options (cont)

Option 19

_____

Dry Contact (programmable models only)

 

 

Option 20

_____

Outdoor Air Temperature Offset Adjustment

 

 

Option 21*

_____

Keypad Lockout

 

 

Option 22

_____

High Cool Latch Temperature

 

 

Option 23

_____

High Heat Latch Temperature

 

 

Option 24*

_____

Programmable/Non-Programmable (programmable models only)

 

 

Option 25*

_____

Number of Programmable Periods Per Day (programmable models only)

 

 

Option 26

_____

Minimum Cooling Setpoint

 

 

Option 27

_____

Maximum Heating Setpoint

 

 

Option 28

_____

UV Light Reminder

 

 

Option 29

_____

Humidifier Pad Reminder

 

 

Option 30*

_____

Programmable Fan (programmable models only)

 

 

Option 31*

_____

Daylight Savings Time Configuration (programmable models only)

 

 

Option 32

_____

Furnace Heat Staging

 

 

Option 33

_____

Single or Two-Piece Installation

 

 

*Options with an asterisk can also be set/changed by the homeowner.

E2007 Bryant Heating & Cooling Systems 7310 W. Morris St.

Indianapolis, IN 46231

Printed in U.S.A.

Edition Date: 09/07

Catalog No: IIT6---PRH---02

Manufacturer reserves the right to change, at any time, specifications

and designs without notice and without obligations.

Replaces: IIT6--- PRH--- 01

80

Image 80
Contents Installation Instructions Table of Contents Safety ConsiderationsIntroduction Installation Considerations PowerModels Humidify Equipment and ConnectionsOutdoor Temperature Sensor Dehumidify Equipment and ConnectionsRemote Indoor Temperature Sensor Two-Piece Thermidistat ConfigurationInstallation T6-PRH Carton ContentsT6-NRH Carton Contents Thermidistat Control LocationInstall Thermidistat Control Unit Damage Hazard Two-Piece Installation Environmental HazardPress Tabs to Remove Backplate Backplate Mounting Relays Secure Wires to Terminal Strip Attach Display to Backplate Equipment Control Module on Equipment Standoff Cover on Equipment Control Module Single-Piece Installation Equipment Control Module Reattach Display Module Set Thermidistat Control Configuration Page Configuration Options -Selection Option 01 Equipment TypeOption 04 Fan G On With W/W1 Option 02 Clean Filter TimerOption 03 Fahrenheit/Centigrade Option 07 Zoning Option 08 Auxiliary Heat Lockout TemperatureOption 06 Cooling Lockout Below 55F Option 09 Heat Pump Lockout Temperature Option 10 Reversing ValveOption 11 Deadband Setting Between Heat & Cool Option 12 Smart RecoveryOption 13 Room Air Temperature Offset Adjust Option 14 Humidity Display Offset AdjustOption 16 Maximum Cycles Per Hour Option 17 Time Between Equipment StagesOption 18 Backlight Configuration Option 19 Dry Contact Configuration programmable models onlyOption 20 Outdoor Air Temperature Offset Adjustment Option 21 Keypad Lockout programmable models onlyOption 21 Keypad Lockout non-programmable models only Option 22 High Cool Latch Temperature Option 23 High Heat Latch TemperatureOption 26 Minimum Cooling Setpoint Option 29 Humidifier Pad Reminder Option 27 Maximum Heating SetpointOption 28 UV Light Reminder Option 30 Programmable Fan programmable models only Option 33 Single or Two-Piece Installation Option 99 Reset to Factory DefaultsSystem START-UP and Checkout Final Settings To Test FANEnergy Star Default Schedule Humidity Control Features HumidificationHumidification Selections To Select Humidification programmableAdditional Humidify Comments DehumidificationTo Select Humidification non-programmable Page Auto Humidity Additional Dehumidify Comments Dehumidify Output and Equipment ConnectionsVacation programmable models only Vacation Setpoints Default Values Vacation SetpointsVacation Humidification Vacation DehumidificationTimers Operational InformationThree-Minute Minimum on Time Equipment On IndicatorsHeat/Cool Setpoints Desired Temperature Humidify and Dehumidify Indicators Emergency Heat ModeAuto Changeover Programmable Fan programmable models onlyTroubleshooting Error CodesPage Equipment Configuration Outputs Equipment Cool HeatTwo-stage Hybrid Heat W2/B Wiring Diagrams Display to Equipment Control Module ConnectionFV/FK Fan Coil w/2-Stage Heat Pump Typical Fan Coil w/Heat Pump A06575 FV/FK Fan Coil w/2-Stage Air Conditioner Typical Fan Coil w/Air Conditioner A06578 FV/FK Fan Coil w/1-Stage Heat Pump Typical Fan Coil Heating Only Thermidistat Control w/Dry Contact Control for Fan Run Time FV/FK Fan Coil w/1-Stage Air Conditioner Typical Fan Coil Cooling Only Variable Speed/Multi-Stage Furnace w/2-Stage Heat Pump Single-Stage Furnace w/Heat Pump Variable Speed/Multi-Stage Furnace w/2-Stage Air Conditioner Single-Stage Furnace w/Air Conditioner Variable Speed/Multi-Stage Furnace w/Single-Stage Heat Pump Single-Stage Furnace Heating Only A06590 Single-stage Furnace with Air Conditioner and Split Power Thermidistat Configuration Record Mode SettingsConfiguration Options Catalog No IIT6---PRH---02

A07045, A07044 specifications

Bryant A07044 and A07045 are two advanced air conditioning units designed for both residential and commercial applications. These models are specifically engineered to provide high-efficiency cooling and optimal indoor comfort. With a focus on innovative technologies, they deliver reliability and performance that meet the demands of today's energy-conscious consumers.

One of the standout features of the Bryant A07044 and A07045 is their impressive Energy Efficiency Ratio (EER). Both models are designed to consume less energy while providing substantial cooling power, which not only reduces utility bills but also contributes to a more sustainable environment. Their high-efficiency refrigerant systems ensure optimal performance even in extreme weather conditions.

Both models incorporate advanced inverter technology, which enables them to modulate cooling output based on the specific needs of the space. This allows for quieter operation and improved temperature control, ensuring that every room is maintained at the desired comfort level without unnecessary energy consumption. The variable-speed compressor adjusts the cooling output, providing more precise temperature regulation.

In terms of installation and integration, both Bryant A07044 and A07045 feature a compact design that makes them ideal for various spaces, whether it's a small apartment, a large commercial space, or anything in between. Their lightweight construction and flexible mounting options simplify the installation process, saving time and labor costs.

User-friendly controls are another significant feature of these models. They come equipped with a digital thermostat that allows homeowners and facility managers to easily program their desired temperatures. Additionally, many Bryant air conditioning units are compatible with smart home systems, enabling remote access and monitoring for added convenience.

Durability is a hallmark of Bryant's engineering, and both the A07044 and A07045 exemplify this commitment. They are constructed with high-quality materials and corrosion-resistant components, ensuring that they can withstand harsh environmental conditions. This longevity is complemented by Bryant's extensive warranty offerings, providing peace of mind for consumers.

In summary, the Bryant A07044 and A07045 air conditioning units stand out for their energy efficiency, advanced inverter technology, user-friendly controls, and robust construction. They are excellent choices for anyone seeking reliable and efficient cooling solutions for their homes or businesses.