Porter-Cable 7724 Carton Contents, Functional Description, Motor, Extension Cord Selection

Page 8

MOTOR

Many Porter-Cable tools will operate on either D.C., or single phase 25 to 60 cycle A.C. current and voltage within plus or minus 5 percent of that shown on the specification plate on the tool. Several models, however, are designed for A.C. current only. Refer to the specification plate on your tool for proper voltage and current rating.

Do not operate your tool on a current on which the voltage is not within correct limits. Do not operate tools rated A.C. only on D.C. current. To do so may seriously damage the tool.

EXTENSION CORD SELECTION

If an extension cord is used, make sure the conductor size is large enough to prevent excessive voltage drop which will cause loss of power and possible motor damage. A table of recommended extension cord sizes will be found in this section. This table is based on limiting line voltage drop to 5 volts (10 volts for 230 volts) at 150% of rated amperes.

If an extension cord is to be used outdoors, it must be marked with the suffix W- A or W following the cord type designation. For example – SJTW-A to indicate it is acceptable for outdoor use.

RECOMMENDED EXTENSION CORD SIZES FOR USE WITH PORTABLE ELECTRIC TOOLS

Length of Cord in Feet

 

115V

25 Ft.

50 Ft.

100 Ft.

150 Ft.

200 Ft.

250 Ft.

300 Ft.

400 Ft.

500 Ft.

 

230V

50 Ft.

100 Ft.

200 Ft.

300 Ft.

400 Ft.

500 Ft.

600 Ft.

800 Ft.

1000 Ft.

 

 

 

 

 

 

 

 

 

 

 

 

0-2

18

18

18

16

16

14

14

12

12

 

 

 

 

 

 

 

 

 

 

 

Rating

2-3

18

18

16

14

14

12

12

10

10

 

 

 

 

 

 

 

 

 

 

3-4

18

18

16

14

12

12

10

10

8

 

 

 

 

 

 

 

 

 

 

4-5

18

18

14

12

12

10

10

8

8

Ampere

5-6

18

16

14

12

10

10

8

8

6

 

 

 

 

 

 

 

 

 

 

6-8

18

16

12

10

10

8

6

6

6

 

 

 

 

 

 

 

 

 

 

8-10

18

14

12

10

8

8

6

6

4

Nameplate

 

 

 

 

 

 

 

 

 

 

10-12

16

14

10

8

8

6

6

4

4

 

 

 

 

 

 

 

 

 

 

12-14

16

12

10

8

6

6

6

4

2

 

 

 

 

 

 

 

 

 

 

14-16

16

12

10

8

6

6

4

4

2

 

 

 

 

 

 

 

 

 

 

 

16-18

14

12

8

8

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

 

 

18-20

14

12

8

6

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

 

SAVE THESE INSTRUCTIONS!

CARTON CONTENTS

1.Porta-Band saw

2.Porta-Band saw blade

FUNCTIONAL DESCRIPTION

FOREWORD

MODEL 7724 PORTER-CABLE Portable Band Saw is designed to cut various types of material up to 43/4" diameter or 41/2" x 43/4" rectangular shape.

8

Image 8
Contents Instruction Variable Speed Manual PORTA-BAND Band Saw Table of Contents Important Safety InstructionsSafety Guidelines Definitions California PropositionGeneral Safety Rules General Safety Rules Additional Specific Safety Rules Symbol Definition Carton Contents Functional DescriptionMotor Extension Cord SelectionBand SAW Blades Assembly OperationTo Start and Stop SAW To Change SAW Blades Which Blade to USEUSE of Lubricants To Adjust Blade Tracking Troubleshooting Maintenance HOW to USE a Portable Band SAWKeep Tool Clean Failure to StartReplacement Parts Service and Repairs ServiceAccessories Warranty PORTER-CABLE Limited ONE Year WarrantyCanadian PORTER-CABLE Delta Service Centers