Bryant 598A manual Operating Your AIR Conditioner, Ventilation, Zoning, Check Condensate Drain

Page 3

LCD READOUT DISPLAYS CURRENT ROOM TEMPERATURE, DESIRED ROOM TEMPERATURE, UNIT MODE SETTING, AND FAN MODE SETTING

Thermostat

RESET/FILTERFAN MODE

UP AND DOWN BUTTONS INCREASE OR DECREASE THE DESIRED TEMPERATURE SETTINGS

 

MODE BUTTON SELECTS

 

BETWEEN OFF, HEAT,

 

COOL, AND AUTO OPERATION

RESET FILTER BUTTON

FAN BUTTON CHOOSES

RESTARTS THE TIMER

BETWEEN ON OR AUTO

THAT CALCULATES

FAN OPERATION

THE NEXT AIR FILTER

 

CHANGE OR CLEANING

 

Fig. 2—Bryant Non-Programmable Two-Speed Thermostat

mechanical air cleaners and/or humidifi- ers offer the added benefits of having the air continuously cleaned year-round, and humidified during the winter season.

Ventilation

A system equipped with a heat or energy recovery ventilator offers the advantage of exhausting stale air from the home and allowing fresh air in from the outdoors while minimizing heat loss.

Zoning

Your system may also be equipped with a zoning system which allows individual

control over the temperatures of separate areas of your home.

Check Condensate Drain

Your air conditioner will remove humid- ity from your home during the cooling season. After a few minutes of operation, you should be able to see water trickle from the condensate drain of the cooling coil. Check this occasionally

to be sure the drain system is not clogged. Do not expect to see much drainage

if you live in a very dry environment.

When Not To Use Your Unit

Do not operate your unit when outdoor temperatures are below 55°F.

OPERATING YOUR AIR CONDITIONER

The operation of your air conditioning system is controlled by the indoor ther- mostat. Simply adjust the thermostat to maintain the indoor temperature at the level you select. Most thermostats have three controls: a temperature control selector, a FAN control, and a SYSTEM

MODE BUTTON SELECTS

BETWEEN OFF, HEAT, COOL,

AND AUTO OPERATION

PROGRAM BUTTONS

FOR PROGRAMMING

HEATING/COOLING

CYCLES

Programmable

 

 

Thermostat

 

 

COPY PREVIOUS DAY

PROGRAM

MODE

CHANGE DAY

END

FAN

SET TIME/TEMP

RESET FILTER

HOLD

LCD READOUT DISPLAYS

CURRENT ROOM TEMPERATURE,

DESIRED ROOM TEMPERATURE

OR OUTDOOR TEMPERATURE,

UNIT MODE SETTING,

FAN MODE SETTING,

AND TIME OF DAY

UP AND DOWN

BUTTONS INCREASE

OR DECREASE THE

DESIRED TEMPERATURE

SETTINGS

SET TIME

FAN BUTTON CHOOSES

BUTTON

BETWEEN ON OR AUTO

 

FAN OPERATION

RESET FILTER BUTTON

HOLD BUTTON MAINTAINS

RESTARTS THE TIMER

THE CURRENT TEMPERATURE

THAT CALCULATES

AND OVERRIDES PROGRAMMED

THE NEXT AIR FILTER

TEMPERATURE CHANGES

CHANGE OR CLEANING

UNTIL RESET

Fig. 3—Bryant Programmable Two-Speed Thermostat

3

Image 3
Contents Model 598A Do Not Block Registers Keep Filter CleanAir Cleaners and Humidifiers Identifying Your SystemZoning When Not To Use Your UnitOperating Your AIR Conditioner VentilationPerforming Routine Maintenance Cooling CycleHeating Cycle Before YOU Request a Service Call For the Record Regular Dealer MaintenancePage Accessories

598A specifications

The Bryant 598A is a state-of-the-art air conditioning unit designed to deliver optimal indoor comfort while maintaining energy efficiency. Ideal for residential applications, this model boasts several notable features and advanced technologies that cater to the needs of modern homeowners.

One of the standout characteristics of the Bryant 598A is its impressive SEER (Seasonal Energy Efficiency Ratio) rating. With a SEER rating of up to 16, it provides significant energy savings compared to older models, making it an eco-friendly choice. This efficiency is a result of Bryant's commitment to utilizing cutting-edge engineering and technology in their products.

The Bryant 598A is equipped with a two-stage compressor, which allows it to operate at optimal levels depending on the cooling demand. This feature not only enhances comfort by providing consistent temperatures but also reduces energy consumption by avoiding the common inefficiencies associated with single-stage units. Additionally, it offers a quiet operation, ensuring that your indoor environment remains peaceful while the system works effortlessly in the background.

This air conditioning unit incorporates advanced refrigerant technology, specifically designed to use environmentally friendly R-410A refrigerant. This not only meets stringent regulatory requirements but also contributes to a lower environmental impact while ensuring reliable performance throughout the cooling season.

Another key feature of the Bryant 598A is its compatibility with smart home technology. Homeowners can integrate this unit with various smart thermostats, allowing for remote control and enhanced scheduling capabilities. This means you can adjust your cooling preferences even when you're not at home, leading to further energy savings and convenience.

Durability and reliability are also at the forefront of the Bryant 598A design. Constructed with a robust cabinet that can withstand the elements, this air conditioner is built to last, offering peace of mind for homeowners. Its weather-resistant materials protect against corrosion and damage, ensuring that it maintains its performance over the years.

In summary, the Bryant 598A is an efficient, reliable, and technologically advanced air conditioning solution. With features that enhance comfort and energy savings, along with smart compatibility, it stands as a top choice for homeowners looking to upgrade their cooling systems while being environmentally conscious.