Bryant 598A manual Before YOU Request a Service Call

Page 5

!WARNING

To prevent personal injury or death disconnect all electrical power to the air conditioner be- fore removing access panels or performing any maintenance. Disconnect power to both the indoor and outdoor units. Note: there may be more than 1 elec- trical disconnect switch.

!CAUTION

Although special care has been taken to minimize sharp edges in the construction of your unit, be extremely careful when handling parts or reach- ing into the unit.

CHECK THE AIR FILTER

A dirty air filter will cause excessive strain on the compressor and blower motor. This can cause the components to overheat and automatically shut down. In the extreme, the components will fail and need to be replaced. To avoid inefficient operation or failure of your unit, CHECK THE FILTER(S) EVERY 3 TO 4 WEEKS. Replace filter(s) when neces- sary, or clean the filter(s) if you have the reusable type.

Disposable filters should be replaced by similar, new filters of the same dimensions.

Reusable, permanent filters should

be washed in a solution of cold water and mild detergent, then rinsed and thoroughly dried. THE FILTER MUST BE COMPLETELY DRY BEFORE BEING REINSTALLED. To avoid pro- longed shutdown of your unit while a filter is drying, you should have an extra filter on hand. This would allow you to switch between the two with minimal downtime for your comfort system. Extra filters may be purchased from your dealer.

There are no filters in the outdoor unit of a split system. If your indoor unit is a gas or oil furnace, refer to your furnace Owner's Manual for filter location and procedures for replacement or cleaning.

tensioner, slide the tray into the unit, then secure the thumbscrews.

INDOOR COIL

If the indoor coil has only been operated with a clean filter in place, it should require minimal cleaning.

If coil cleaning is required, call your dealer for service. It may be necessary to clean the coil with a detergent solution and rinse it with water, which could require removing the coil. Do not attempt this yourself.

OUTDOOR COIL

If grass clippings, leaves, shrubbery, and debris are kept away from the outdoor unit, minimal care should keep the sys- tem functioning properly. For proper drainage, debris must be removed period- ically from the base pan. However, if the outdoor coil becomes dirty, use a vacuum cleaner with soft brush attachment to clean the exterior surface. Vacuum coil surface using an up and down motion. Be careful not to bend or damage coil fins. If dirt is deep in the coil, contact your dealer for service. The outdoor fan motor may have to be disconnected and the top panel removed to gain access to the coil for thorough cleaning. Do not attempt this yourself.

OUTDOOR COIL—

SEA COAST

If your unit is located near the ocean, spe- cial maintenance is required. Ocean mist/ breeze carries salt, which is corrosive to most metals. Although your new unit is made out of galvanized metal and is pro- tected by top-grade paint, you should take the precaution of additional mainte- nance by periodically washing the unit. By washing all exposed surfaces and coil

approximately every 3 months, you will be adding life to your unit. Consult your installing contractor for proper intervals/ procedures for your geographic area or service contact.

UNIT SUPPORT

Your split-system outdoor unit should be maintained at a level position. If its sup- port shifts or settles so that the unit is no longer level, you should correct the condition. Relevel it promptly to assure that water drains out of the unit. If you notice that water or ice collects beneath the unit, arrange for it to be drained away from the unit.

BEFORE YOU REQUEST A SERVICE CALL

CHECK FOR THESE EASILY SOLVED PROBLEMS:

Check the indoor and outdoor discon- nect switches. Verify that circuit breakers are on or that fuses have not blown.

Check for sufficient airflow. Check the air filter(s) for any accumulations of dirt. Check for blocked return-air or supply- air registers. Be sure registers are open and unobstructed.

Check the settings on your indoor ther- mostat. If you desire cooling, see that the temperature control selector is set below room temperature and the SYSTEM or MODE control is set to COOL or AUTO. If you require heat, be sure the tempera- ture control selector is set above room temperature and the SYSTEM or MODE control is set to HEAT or AUTO. The FAN control should be set to ON for con- tinuous blower operation or AUTO if you wish blower to function only while the unit is operating.

If your system includes an indoor fan- coil unit, the filter is located in the unit where it connects with the return-air duct or plenum. (See Fig. 5.) Remove the two black thumbscrews (or plastic pull rings on modular fan coil), then pull out the rack and filter. The clean filter must be reinstalled with the cross-hatched (when used) side facing the blower. With the clean filter in place, secure the spring

Fig. 5—Removing Filter from Fan Coil Unit

5

Image 5
Contents Model 598A Air Cleaners and Humidifiers Keep Filter CleanIdentifying Your System Do Not Block RegistersOperating Your AIR Conditioner When Not To Use Your UnitVentilation ZoningHeating Cycle Performing Routine MaintenanceCooling Cycle Before YOU Request a Service Call For the Record Regular Dealer MaintenancePage Accessories

598A specifications

The Bryant 598A is a state-of-the-art air conditioning unit designed to deliver optimal indoor comfort while maintaining energy efficiency. Ideal for residential applications, this model boasts several notable features and advanced technologies that cater to the needs of modern homeowners.

One of the standout characteristics of the Bryant 598A is its impressive SEER (Seasonal Energy Efficiency Ratio) rating. With a SEER rating of up to 16, it provides significant energy savings compared to older models, making it an eco-friendly choice. This efficiency is a result of Bryant's commitment to utilizing cutting-edge engineering and technology in their products.

The Bryant 598A is equipped with a two-stage compressor, which allows it to operate at optimal levels depending on the cooling demand. This feature not only enhances comfort by providing consistent temperatures but also reduces energy consumption by avoiding the common inefficiencies associated with single-stage units. Additionally, it offers a quiet operation, ensuring that your indoor environment remains peaceful while the system works effortlessly in the background.

This air conditioning unit incorporates advanced refrigerant technology, specifically designed to use environmentally friendly R-410A refrigerant. This not only meets stringent regulatory requirements but also contributes to a lower environmental impact while ensuring reliable performance throughout the cooling season.

Another key feature of the Bryant 598A is its compatibility with smart home technology. Homeowners can integrate this unit with various smart thermostats, allowing for remote control and enhanced scheduling capabilities. This means you can adjust your cooling preferences even when you're not at home, leading to further energy savings and convenience.

Durability and reliability are also at the forefront of the Bryant 598A design. Constructed with a robust cabinet that can withstand the elements, this air conditioner is built to last, offering peace of mind for homeowners. Its weather-resistant materials protect against corrosion and damage, ensuring that it maintains its performance over the years.

In summary, the Bryant 598A is an efficient, reliable, and technologically advanced air conditioning solution. With features that enhance comfort and energy savings, along with smart compatibility, it stands as a top choice for homeowners looking to upgrade their cooling systems while being environmentally conscious.