REMOVE CHUCK

HAMMER

ALLEN

WRENCH

SUPPORT

Fig. 5

INSTALL CHUCK

HAMMER

ALLEN

WRENCH

SUPPORT

Fig. 6

6.Remove allen wrench from chuck.

7.INSTALL CHUCK RETAINING SCREW: Turn screw counterclockwise with a “flat” screwdriver. Tighten securely.

BRUSH INSPECTION AND LUBRICATION

For your continued safety and electrical protection, brush inspection and replacement on this tool should ONLY be performed by an AUTHORIZED PORTER-CABLE SERVICE STATION or a PORTER-CABLE/DELTA FACTORY SERVICE CENTER.

At approximately 100 hours of use, take or send your tool to your nearest authorized Porter-Cable Service Station to be thoroughly cleaned and inspected. Have worn parts replaced and lubricate with fresh lubricant. Have new brushes installed, and test the tool for performance.

Any loss of power before the above maintenance check may indicate the need for immediate servicing of your tool. DO NOT CONTINUE TO OPERATE TOOL UNDER THIS CONDITION. If proper operating voltage is present, return your tool to the service station for immediate service.

SERVICE AND REPAIRS

All quality tools will eventually require servicing or replacement of parts due to wear from normal use. These operations, including brush inspection and replacement, should ONLY be performed by either an AUTHORIZED PORTER-CABLE SERVICE STATION or a PORTER-CABLE/DELTA FACTORY SERVICE CENTER. All repairs made by these agencies are fully guaranteed against defective material and workmanship. We cannot guarantee repairs made or attempted by anyone other than these agencies.

Should you have any questions about your tool, feel free to write us at any time. In any communications, please give all information shown on the nameplate of your tool (model number, type, serial number, etc.).

10

Image 10
Contents Double Insulated Important Safety Instructions Read and Follow ALL InstructionsAdditional Safety Rules for Portable Drills Motor Replacement PartsExtension Cord Selection Functional Description Installing and Removing Drill BITForeword To Install Auxiliary Handle To Start and Stop DrillHOW to Hold the Drill General Drilling HOW to USE the DrillDrilling Wood Chuck Replacement MaintenanceKeep Tool Clean Drilling MetalService and Repairs Brush Inspection and LubricationAccessories PORTER-CABLE Limited ONE Year Warranty Canadian PORTER-CABLE Delta Service Centers