UNIT INTRODUCTION

This 577D unit is a small packaged gas heat/electric cooling system that can utilize the comfort of gas heating packaged along with effi- cient electric air conditioning. This unit uses Puron®, the environ- mentally friendly refrigerant, for cooling.

OPERATING YOUR UNIT

The operation of your unit is controlled by the Evolutiont User In- terface (UI). You simply program the UI and it maintains the indoor temperature at the level you select. See UI manual for detailed in- structions.

To better protect your investment and to eliminate unnecessary ser- vice calls, familiarize yourself with the following facts:

To start unit gas heat:

Refer to Fig. 2 for location of unit front access panel. Refer to Fig. 3 for location of gas valve. Refer to Fig. 4 while proceeding with the following steps.

1.Set the temperature selector on UI to the lowest temperature setting and set system switch to HEAT.

2.Close the external manual gas shutoff valve.

3.Turn off the electrical supply to the unit.

4.Remove the front access panel with a 5/16-in. nut driver.

5.Move the selector switch on the internal gas valve to the OFF position and wait 5 minutes.

6.Move the selector switch on the internal gas valve to the ON position.

7.Replace the front access panel.

8.Turn on the electrical supply to unit.

9.Open the external manual gas shutoff valve.

10.Set the temperature selector on UI slightly above room tem- perature to start unit. The induced-draft combustion air fan will start. Main gas valve will open and main burners should ignite within 5 seconds. If the burner does not light within 5 seconds, the ignition module will go into a Retry Mode after a period of approximately 22 seconds (following the 5-second ignition period). If the burners do not light within 15 minutes of the initial call for heat, there is a lockout.

11.Set the temperature selector on UI to desired setting.

Filter Access Panel

For Accessory Filter Rack

Access Panels

A09045

Fig. 2 - Accessory Filter Rack Access Panel

Flue Hood

Burners Gas Valve

A09043

Fig. 3 - Gas Heating/Electric Cooling Unit with Access Panel Removed (Standard unit shown. Actual appearance is shown in Fig. 2.)

!WARNING

FIRE AND EXPLOSION HAZARD

Failure to follow this warning could result in personal injury, death, and/or property damage.

1.If the main burners fail to light, or the blower fails to start, shut down gas heating section and call your dealer for service.

2.Never attempt to manually light the main burners on unit with a match, lighter, or any other flame. If the electric sparking device fails to light the main burners, refer to the following shutdown procedures, then call your dealer as soon as possible.

To shut off unit gas heat:

!WARNING

FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury, death, and/or property damage.

Do not turn off the electrical power to unit without first turning off the gas supply.

Note:If the unit is being shut down because of a malfunction, call your dealer as soon as possible.

Should overheating occur or the gas supply fail to shut off, shut off the external manual gas valve to the unit before shutting off the elec- trical supply. Do not use this unit if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.

Refer to Fig. 4 while proceeding with the following steps.

1.Set the temperature selector on UI to lowest temperature set- ting and set system SWITCH to OFF.

2.Close the external manual shutoff valve.

3.Turn off the electrical power supply to the unit.

4.Remove the front access panel.

5.Move the selector switch on the internal gas valve to the OFF position.

To start unit electric cooling:

Refer to Fig. 5 while proceeding with the following steps.

1.Set the temperature selector on UI to highest temperature setting and set system SWITCH to OFF.

2.Close the external manual shutoff valve.

3.Turn off the electrical power supply to the unit.

3

Image 3
Contents Owner’s Information Manual Fire and Explosion Hazard Safety ConsiderationsFor Your Safety FIRE, EXPLOSION, Electrical Shock HazardTo shut off unit gas heat Unit IntroductionOperating Your Unit To start unit gas heatTo shut off unit electric cooling To Start Unit Gas HeatRoutine Maintenance Cooling ModeGas Heating Mode Maintenance and ServiceTo Start Unit Electric Cooling Maintenance and Care for the Equipment Owner FIRE, EXPLOSION, Electrical Shock and CUT HazardFire and Unit Operation Hazard EXPLOSION, Burn and Environmental Hazard Personal Injury and Unit Damage Hazard

577D specifications

The Bryant 577D is a distinguished model in the world of HVAC (Heating, Ventilation, and Air Conditioning) systems, tailored for residential and commercial applications. This unit offers a perfect blend of innovation and efficiency, catering to the needs of users who seek reliability and performance.

One of the most notable features of the Bryant 577D is its advanced two-stage heating capability. This allows the system to operate at two different heating levels, providing customized comfort depending on the conditions. The dual-stage operation optimizes energy consumption by running at a lower stage during milder conditions and ramping up to a higher stage when the cold becomes more severe. This not only enhances comfort but also contributes to lower energy bills.

The Bryant 577D utilizes a variable-speed blower motor, a technology that significantly improves air distribution and comfort levels in any space. With the ability to adjust airflow based on the specific demands of the environment, it reduces noise levels while ensuring consistent heating throughout the area. This feature is particularly beneficial in achieving a quieter operation, making it suitable for both home and office environments.

In terms of efficiency, the Bryant 577D boasts impressive energy efficiency ratings. It is designed to meet or exceed the latest energy efficiency standards. This not only helps in reducing carbon footprints but also translates into significant savings on energy costs over time. The unit’s design incorporates high-quality insulation and advanced heat exchanger technology, further enhancing its efficiency.

Combining durability and performance, the Bryant 577D is built with robust materials that ensure long-lasting operation. Its compact design allows for easier installation and maintenance. The model comes equipped with advanced diagnostics, making it simpler for technicians to identify and address issues quickly.

To enhance user convenience, the Bryant 577D is compatible with smart thermostat technologies, allowing homeowners to control their HVAC system remotely. This capability to easily program heating schedules and monitor performance through smartphones adds a layer of flexibility that modern consumers value.

In summary, the Bryant 577D stands out with its two-stage heating, variable-speed blower motor, energy efficiency, and durable design. Its commitment to providing comfort and reliability while remaining energy-efficient makes it a leading choice for those in search of high-quality HVAC solutions. Whether for residential or commercial use, the Bryant 577D is engineered to meet diverse heating needs efficiently.