Troubleshooting the DT45
Trouble
Machine will not start/restart or repeatedly trips circuit breakers or blows fuses.
Probable Cause | Remedy | |
|
| |
Machine not plugged in. | Verify machine is connected to power. | |
|
| |
Fuse blown, or circuit | Replace fuse, or reset circuit breaker. | |
breaker tripped. | ||
| ||
|
| |
Cord damaged. | Replace cord. | |
|
| |
| If the Dovetailer overloads on the circuit breaker | |
| built in to the motor starter, it takes time for the | |
Overload automatic reset | machine to cool down before restart. Allow unit to | |
has not reset. | adquately cool before attempting restart. If problem | |
| persists, check amp setting on the motor starter | |
| inside the electrical box. | |
|
| |
| Check the amp setting on the overload relay. | |
| Match the full load amps on the motor as noted on | |
Dovetailer frequently trips. | the motor plate. If amp setting is correct then there | |
| is probably a loose electrical lead or a failed | |
| component. See below. | |
|
| |
Building circuit breaker trips | Verify that dovetailer is on a circuit of correct size. | |
If circuit size is correct, there is probably a loose | ||
or fuse blows. | ||
electrical lead. Check amp setting on motor starter. | ||
| ||
|
| |
| Go through all of the electrical connections on the | |
Loose electrical | dovetailer including motor connections, verifying | |
the tightness of each. Look for any signs of | ||
connections. | ||
electrical arcing which is a sure indicator of loose | ||
| ||
| connection or circuit overload. | |
|
| |
| If you have access to a voltmeter, you can | |
| separate a starter failure from a motor failure by | |
| first, verifying incoming voltage at | |
| second, checking the voltage between starter and | |
Motor starter failure. | motor at | |
| you have a power supply problem. If voltage | |
| between starter and motor is incorrect, you have a | |
| starter problem. If voltage between starter and | |
| motor is correct, you have a motor problem. | |
|
| |
| If electric motor is suspect, you have two options: | |
| Have a qualified electrician test the motor for | |
Motor failure. | function or remove the motor and take it to a | |
| qualified electric motor repair shop and have it | |
| tested. | |
|
| |
| Check to make certain all electrical connections | |
| are correct and properly tight. The electrical | |
| connections other than the motor are | |
Miswiring of the unit. | preassembled and tested at the factory. Therefore, | |
| the motor connections should be checked as the | |
| highest probability for error. If problems persist, | |
| double check the factory wiring. | |
|
|
22