U5047A PAG QUASAR INSTRUCTION MANUAL
SECTION 4
OPERATING INSTRUCTIONS
4.1POWERING UP
Connect the charger to a suitable supply using the standard lead supplied. The LCD screen will illuminate and briefly display the PAG logo and charger model before entering normal operating mode. With no batteries connected, all channels will indicate absent. Quasar chargers may be disconnected from the supply at any time in complete safety and without damage to the charger or any batteries connected.
IMPORTANT: Note section 4.10, Supply Failure. The charger remembers the status of batteries when the mains supply is disconnected. If the charger has been previously disconnected from the supply with charged batteries connected, it is important to connect the charger to the supply BEFORE connecting another set of batteries.
4.2THE SCREEN
The screen displays two lines of information. The top line indicates battery status, and the lower line indicates battery voltage, charge loaded, and discharge capacity. The lower line also confirms charge rate selection.
Battery status is indicated by means of text messages. Where the battery is not undergoing a process, these messages are displayed in a steady state. Where the battery is undergoing a process, the message blinks. Due to space considerations, text messages are abbreviated. Indications are as follows:
Indication: | Appearance: | Status: |
|
|
|
|
| ||
ABST | Continuous | No battery connected | ||
WAIT | Continuous | Waiting in queue for charge | ||
CHRG | Blinking | Charging in progress | ||
BLNC | Blinking | Balance charge in progress | ||
DONE | Continuous | Program | completed | |
FAIL | Continuous | Battery | unsuitable | for processing |
|
|
|
| |
RCVY | Blinking | Recovery charge in | progress | |
|
|
|
|
|
|
| U5047A PAG QUASAR INSTRUCTION MANUAL |
|
|
|
WAIT/°C | Alternate | Waiting - battery too hot or cold |
|
|
|
CHRG/NiMH | Alternate | Charging of PAG NMH in progress |
|
|
|
CHRG/Liion | Alternate | Charging of PAG |
|
| |
|
|
|
4.3THE FUNCTION BUTTON
Operating modes and display options are selected by means of the Function button, the operation of which can be summarised as follows:
Hold in while connecting supply: selects charge rate menu.
Press once: displays charge loaded.
Press twice: selects Recovery Charge program for channel 1. A further button press moves the selection to channel 2.
In Camera Power Supply Mode (models 9752 & 9753 only): disconnect camera and press Function Button for one second to exit Power Supply mode.
4.4CHANGING THE CHARGE RATE
IMPORTANT: DO NOT CHANGE THE SETTING FROM AUTO MODE UNLESS THERE IS A GOOD REASON FOR DOING SO, AND THE IMPLICATIONS OF CHARGING AT THE ALTERNATIVE RATE ARE FULLY UNDERSTOOD.
AUTO MODE: The charger is set to the Auto Mode before leaving the factory. Auto Mode automatically selects the most appropriate charge rate for all specified batteries, and it is designed so that even at the lowest rate it can charge batteries up to 10Ah capacity.
2A CHARGE RATE:
3A CHARGE RATE:
7 | 8 |