SYSTEM DESIGN

1.Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.

2.Minimum outdoor operating air temperature without low ambient operation accessory is 55°F (12.8°C).

3.Maximum outdoor operating air temperature is 125°F (51.7°C).

4.For reliable operation, unit should be level in all horizontal planes.

5.Maximum elevation of indoor coil above or below base of outdoor unit is: Indoor coil above = 50 ft indoor coil below = 150 ft. (See items 6 and 7 following.)

6.For interconnecting refrigerant tube lengths of 50 to 175 ft or 20 ft vertical differential, consult Long-Line Application Guideline available from equipment distributor.

7.Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft.

8.If any refrigerant tubing is buried, provide a minimum 6-in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. may be buried without further consideration. For buried lines longer than 3 ft, consult your local distributor.

9.Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.

10.Mismatches of indoor coil capacity more than 1 size larger than outdoor unit capacity may result in inadequate indoor comfort.

—27—

Image 27
Contents Model 593C 60 Hz Unit Unit Dimensions Minimum Mounting Size DimensionsPiston Recommended Tube DiametersCHECK-FLO-RATER Piston Liquid Tube Diameter Vapor Tube Diameter UnitElectrical SpecificationsSpecifications Ball Bearing Fan Motor Accessory Description and Usage Listed AlphabeticallyRequired for LOW-AMBIENT LONG-LINE Accessory Description and USE Listed AlphabeticallyAccessory Usage Guideline Sound Power dBAEnhance Standard Combination RatingsFactory Bryant GAS TOT Furnace or Unit Indoor30,0000 Combination RatingsCoils + 315A,JAV066110 VARIABLE-SPEED Furnace CC5A/CD5AC048 048-C FG3AAA060 CC5A/CD5AW060 57,000 Coils + 355MAV042060 VARIABLE-SPEED Furnace Evaporator Condenser Entering AIR Temperatures FEWB Coils + 355MAV042040 VARIABLE-SPEED FurnaceCoils + 315A,JAV036070 VARIABLE-SPEED Furnace Detailed Cooling CapacitiesCoils + 315A,JAV048090 VARIABLE-SPEED Furnace CFM EWBCoils + 355MAV060080 VARIABLE-SPEED Furnace Coils + 355MAV060100 VARIABLE-SPEED FurnaceFK4C,DNB 036 042 See notes on Coils + 315A,JAV066135 VARIABLE-SPEED Furnace Coils + 315A,JAV066155 VARIABLE-SPEED FurnaceCoils + 315A,JAV066110 VARIABLE-SPEED Furnace 048 593C048-C Outdoor Section With CC5A/CD5AA048 Indoor Section 060 See notes on 593C060-C Outdoor Section With CC5A/CD5AW060 Indoor Section Condenser only Ratings SST Condenser Entering AIR Temperatures F593C042-C, D Condenser only RatingsSystem Design Products General

593C specifications

The Bryant 593C is a remarkable model that stands as a testament to modern heating, ventilation, and air conditioning (HVAC) technology. Designed with efficiency and reliability in mind, the Bryant 593C offers a blend of features that cater to residential and light commercial needs. At the heart of its appeal is the exceptional efficiency level, achieving a high Seasonal Energy Efficiency Ratio (SEER) rating, which translates into substantial energy savings over time.

One standout characteristic of the Bryant 593C is its innovative two-stage compressor. This feature allows the unit to operate at different capacities, optimizing performance based on the demands of the environment. In moderate conditions, the system runs at a lower capacity, conserving energy while maintaining comfort. During extreme temperatures, the compressor ramps up to high capacity, ensuring that the indoor space remains comfortable regardless of external weather conditions.

The Bryant 593C is also equipped with advanced humidity control capabilities. Its variable-speed fan is instrumental in precisely adjusting airflow, leading to better humidity management throughout the home. This not only enhances comfort levels but also promotes a healthier indoor environment by reducing the likelihood of mold and mildew.

To ensure durability, the Bryant 593C incorporates a robust construction with corrosion-resistant materials. Its powder-coated finish protects the unit from harsh weather conditions, prolonging its lifespan. Additionally, the unit features quiet operation technology. This includes a sound-dampening design that minimizes noise levels, allowing homeowners to enjoy their indoor environment without disruptive sounds.

In terms of technology, the Bryant 593C is compatible with smart thermostats, enhancing user control over the heating and cooling processes. Homeowners can easily manage their indoor climate and energy consumption through user-friendly interfaces and smartphone applications. This connectivity is a significant advantage in energy management and convenience.

Furthermore, the Bryant 593C is designed with eco-friendliness in mind. It uses advanced refrigerants that are less detrimental to the ozone layer compared to traditional options, aligning with energy conservation goals and environmental sustainability.

In conclusion, the Bryant 593C is a state-of-the-art HVAC solution, combining efficiency, comfort, and sustainability. Its dual-stage compressor, humidity control, quiet operation, and smart integration make it a standout choice for those seeking reliable and efficient climate control in their homes or businesses. With its robust design and energy-saving technologies, the Bryant 593C is poised to deliver optimum performance for years to come.