Bryant warranty DIMENSIONS-561C, Unit Dimensions Minimum Mounting Size

Page 2

—2—

 

AIR DISCHARGE

 

A SQ

 

 

M

 

 

 

 

AIR IN

 

AIR DISCHARGE

 

 

 

 

 

 

FIELD POWER SUPPLY CONN

 

 

 

 

7/8-IN. DIA HOLE WITH

 

 

 

 

1 1/8-IN. DIA KNOCKOUT

N

 

 

 

AND 1 3/8-IN. DIA KNOCKOUT

 

 

 

 

 

 

J

 

 

 

 

 

K

AIR IN

 

FIELD CONTROL SUPPLY

AIR IN

 

L

B

CONN 7/8-IN. DIA HOLE

3/8-IN. DIA

 

 

 

 

TIEDOWN

 

 

 

3/8-IN. DIA LIQUID

KNOCKOUTS

 

 

 

(2) PLACES

 

 

 

LINE CONN

 

 

 

 

 

 

 

 

P

 

 

AIR DISCHARGE

 

 

 

2 7/8

C

E

AIR IN

 

 

 

 

 

 

 

 

 

 

F

 

D DIA VAPOR LINE CONN

1 1/4

 

 

 

 

 

 

G

H

NOTES:

1.Allow 30 in. clearance to service side of

unit, 48 in. above unit, 6 in. on one side, 12 in.

on remaining side, and 24 in. between units for proper airflow.

2.Minimum outdoor operating ambient in cooling mode is 55°F, max. 125°F.

3.Series designation is the 14th position of the unit model number.

4.Center of gravity .

A97017

DIMENSIONS (IN.)

 

 

 

 

 

 

 

 

UNIT DIMENSIONS

 

 

 

 

 

 

MINIMUM

UNIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MOUNTING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIZE

SERIES

A

B

C

D

E

F

G

H

J

K

L

M

N

P

PAD DIMENSIONS

018

A, D

18

21-15/16

3-3/16

5/8

3

15

16-5/16

17-3/4

10-3/16

16-1/8

17-3/4

7-7/8

8-3/8

9-3/8

18

X 18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024

A, D

18

23-15/16

3-3/16

5/8

3

15

16-5/16

17-3/4

10-3/16

16-1/8

17-3/4

7-7/8

8-3/8

9-1/2

18

X 18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

030

A, D

22-1/2

21-15/16

3-3/16

3/4

3-11/16

18-1/8

19-3/4

22-1/4

14-3/8

19-9/16

22-1/16

10-3/8

10-1/4

10-3/4

22-1/2

X 22-1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

A, B, D

22-1/2

25-15/16

3-3/16

3/4

3-11/16

18-1/8

19-3/4

22-1/4

14-3/8

19-9/16

22-1/16

10-1/4

9-1/2

11-1/4

22-1/2

X 22-1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

E

22-1/2

25-15/16

3-3/16

3/4

3-11/16

18-1/8

19-3/4

22-1/4

14-3/8

19-9/16

22-1/16

10-3/8

10-3/4

11-1/4

22-1/2

X 22-1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

A, C

22-1/2

29-15/16

3-1/4

7/8

3-11/16

18-1/8

19-13/16

22-1/4

14-3/8

19-9/16

22-1/16

10-1/4

9-1/2

11-5/8

22-1/2

X 22-1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

B

22-1/2

29-15/16

3-1/4

7/8

3-11/16

18-1/8

19-13/16

22-1/4

14-3/8

19-9/16

22-1/16

10-3/8

10-3/4

11-1/8

22-1/2

X 22-1/2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

A, B, C

30

27-15/16

3-1/4

7/8

6-1/2

23-1/2

27-1/4

29-3/4

20

27-1/16

29-9/16

15

13

14-1/2

30

X 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

A, E

30

35-15/16

3-1/4

7/8

6-1/2

23-1/2

27-1/4

29-3/4

20

27-1/16

29-9/16

15-1/2

14

15-1/2

30

X 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060

B

30

29-15/16

3-1/4

7/8

6-1/2

23-1/2

27-1/4

29-3/4

20

27-1/16

29-9/16

15-1/2

14

15

30

X 30

DIMENSIONS—561C

Image 2
Contents 561C 60 Hz Unit Dimensions Minimum Mounting Size DimensionsDIMENSIONS-561C CHECK-FLO-RATER Piston Chart Recommended Tube DiametersSpecifications ElectricalSpecifications 561C048-A, B 561C048-B, C 561C060-A, B 561C060-B, E Applications Accessory Usage GuidelineRequired for LOW-AMBIENT LONG-LINE SEA Coast Outdoor Air Temperature Sensor High-Pressure SwitchLow-Pressure Switch Time-Delay RelayCombination Ratings Combination Ratings Coils + 333B,JAV060120 VARIABLE-SPEED Furnace 10.00 10.10 Btuh Ment Rating TDR† Enhance Standard AccessoryFurnace or Unit Indoor Coils +11.50 10.00 Coils + 333B,JAV036060 VARIABLE-SPEED Furnace Evaporator Condenser Entering AIR Temperatures FCFM EWB Detailed Cooling Capacities Coils + 333B,JAV048080 VARIABLE-SPEED Furnace Size Capacity Power Total Sens‡ KW**Total Sens‡Detailed Cooling Capacities CD5AA Coils + 355MAV060080 VARIABLE-SPEED Furnace Indoor Unit Cooling Unit Cooling Section SizeSection Size MBtuh† SysIndoor Unit Cooling Section Size Coils + 333B,JAV060100 VARIABLE-SPEED Furnace Section Size Capacity PowerSens‡ Total SST Condenser Entering AIR Temperatures F Condenser only Ratings561C042-A, B, C System Design General Products