Bryant 187B installation instructions Safety Considerations, Installation Recommendations

Page 1

187B (2 - 5 TONS)

180B (3 TON TROPHY)

EVOLUTIONt SERIES 2-STAGE AIR CONDITIONER WITH PURONR REFRIGERANT

Installation Instructions

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit. Consult local building codes and current editions of the National Electrical Code ( NEC ) NFPA 70. In Canada, refer to current editions of the Canadian electrical code CSA 22.1.

Recognize safety information. This is the safety-alert symbol !! When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.

Before installing, modifying, or servicing system, main electrical disconnect switch must be in the OFF position and install a lockout tag. There may be more than 1 disconnect switch. Lock out and tag switch with a suitable warning label.

!CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury.

Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing and gloves when handling parts.

Indoor Thermostat Control Options

 

Evolution

Standard

Model

2---stage

Control

 

Thermostat

 

 

 

 

 

187B / 180B

Yes

Yes

 

 

 

INSTALLATION RECOMMENDATIONS

NOTE: In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment.

1.Locate unit away from windows, patios, decks, etc. where unit operation sound may disturb customer.

2.Ensure that vapor and liquid tube diameters are appropriate for unit capacity.

3.Run refrigerant tubes as directly as possible by avoiding un- necessary turns and bends.

4.Leave some slack between structure and unit to absorb vi- bration.

5.When passing refrigerant tubes through the wall, seal open- ing with RTV or other pliable silicon-based caulk. (See Fig. 1.)

6.Avoid direct tubing contact with water pipes, duct work, floor joists, wall studs, floors, and walls.

7.Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap which comes in direct contact with tubing.(See Fig. 1.)

8.Ensure that tubing insulation is pliable and completely sur- rounds vapor tube.

9.When necessary, use hanger straps which are 1 in. (25.4 mm) wide and conform to shape of tubing insulation. (See Fig. 1.)

10.Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation.

NOTE:Avoid contact between tubing and structure

OUTDOOR WALL

INDOOR WALL

CAULK

LIQUID TUBE

 

INSULATION

VAPOR TUBE

 

THROUGH THE WALL

 

JOIST

HANGER STRAP

 

(AROUND VAPORTUBE ONLY)

INSULATION

 

VAPOR TUBE

1” (25.4 mm) MIN.

 

 

 

 

 

 

 

 

LIQUID TUBE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUSPENSION

A94026

Fig. 1 - Piping Installation

Image 1
Contents Installation Recommendations Safety ConsiderationsElectrical Shock Hazard CUT HazardInstallation Unit Operation and Safety Hazard Install Liquid-Line Filter Drier IndoorOutdoor Unit Connected to Factory Approved Indoor Unit Refrigerant Tubing Connection OutdoorMake Electrical Connections Compressor Crankcase Heater System Functions and Sequence of OperationAirflow Selections ECM Furnaces non commu- nicating Airflow Selection for FV4C Fan Coils non-com- municatingCommunication and Status Function Lights Time DelaysCompressor Operation Crankcase Heater OperationCheck Charge Evolution Controlled Low Ambient CoolingFinal Checks Care and MaintenanceTroubleshooting Major Components Temperature ThermistorsAmber Operation Fault TroubleshootingPossible Cause and Action FlashVS Furnace or Fan Coil Wiring with Communicating 2-Stage AC Puronr R-410A Refrigerant Quick Reference Guide Catalog No. II180---187B---01

187B specifications

The Bryant 187B is a cutting-edge heating and cooling solution designed for efficiency and performance in residential and light commercial applications. This HVAC unit incorporates advanced technologies that prioritize energy savings, user comfort, and reliability.

One of the primary features of the Bryant 187B is its two-stage cooling and heating capability. This technology allows the system to operate at lower capacity most of the time, which not only saves energy but also enhances indoor comfort by minimizing temperature fluctuations. When the demand increases, the system automatically ramps up to meet the needs, providing a consistent and comfortable environment.

Efficiency is a hallmark of the Bryant 187B, boasting a SEER rating of up to 18.5 and an AFUE rating of 80%. These ratings signify that the unit exceeds minimum efficiency requirements, leading to lower energy bills and a reduced carbon footprint. The inclusion of environmentally friendly refrigerants, such as R-410A, further emphasizes its commitment to sustainable practices.

Another notable characteristic of the Bryant 187B is its Quiet Operation technology. The unit is designed with sound-dampening features that reduce operational noise, ensuring that the indoor environment remains peaceful. This is particularly valuable in residential areas where noise pollution can be a concern.

The Bryant 187B also comes equipped with advanced thermostat compatibility, allowing homeowners to integrate smart home technologies seamlessly. This feature enables remote temperature control and scheduling, leading to more efficient energy use and enhanced comfort. Users can easily adjust settings through mobile applications, ensuring that their home is always at the desired temperature upon arrival.

Reliability is a key aspect of the Bryant 187B, featuring a robust construction designed to withstand various environmental conditions. With a durable cabinet and high-quality components, this unit is built to last and requires minimal maintenance.

Overall, the Bryant 187B exemplifies modern HVAC technology, combining efficiency, comfort, and reliability into a single cohesive system. It remains an excellent choice for those seeking an effective solution for heating and cooling needs, ensuring that homes remain comfortable throughout the year while being mindful of energy consumption.