908987 - 12-20-02.qxd 12/17/02 10:08 AM Page 11
A rubber nose cushion (C) Fig. 26, is provided to reduce marring of the work surface. The rubber cushion can be pulled off to provide increased
Disconnect tool from air supply before removing or re- installing rubber cushion.
CLEARING A JAMMED FASTENER
Disconnect tool from air supply.
1.Open feeder cover and magazine nail holder. Remove any remaining fasteners from the nailer.
2.Use a slender, soft steel rod to drive the driver blade to its uppermost position. Use needle nose pliers to remove the jammed fastener (see Fig. 28).
3.Follow instructions in PREPARING THE TOOL to reload fasteners.
Fig. 27
Fig. 28
D
A
MAINTENANCE
CLEAN AND INSPECT DAILY
Disconnect tool from air supply before cleaning and inspection. Correct all problems before placing the tool back in use.
Wipe tool clean and inspect for wear or damage. Use
Inspect trigger and safety mechanism to assure system is complete and functional: no loose or missing parts, no binding or sticking parts.
Keep all screws tight. Loose screws can cause personal injury or damage tool.
If tool is used without an
11