Porter-Cable 8604, BN200V12 instruction manual LED Status Diagnostic Conition Action

Page 11

901891 - 08-31-01.qxd 2/13/02 11:52 AM Page 11

WARNING: Disconnect tool from air supply and/or remove battery before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location, handing the tool to another person, making adjustments.

WARNING: Clean and inspect tool daily. Carefully check for proper operation of trigger and safety mechanism. Do Not use the tool unless both the trigger and the safety mechanism are functional, or if the tool is leaking air or needs any other repair.

Built in LED self diagnostics (B) Fig. 19 inform the user to the tool’s operation status. Tool operation safety status is outlined in the following chart.

LED STATUS

DIAGNOSTIC CONITION

ACTION

Solid Green LED

Tool up to pressure and

Use tool in normal manner.

 

safe to operate.

 

 

 

 

Flashing Green

Tool pressure building.

Wait for Solid Green.

LED

 

 

Fast Flashing

Quick connect valve open.

 

Red LED

 

 

Slow Flashing

Auto shut down activated.

 

Red LED

 

Rotate quick connect valve to 8 o’clock closed position see (A) Fig. 14A.

Turn tool off and on to reset.

Solid Red LED

Low voltage.

Recharge battery.

B

 

A

HIGH

 

 

NORMAL

 

 

 

 

OFF

Fig. 19

 

EXT AIR

A

Fig. 19A

The depth to which a fastener is driven is controlled by the depth adjustment knob (A) Fig. 19A. The depth of drive is factory adjusted to a nominal setting. Test fire a fastener and check depth. If a change is desired, rotate the adjustment knob (A) Fig. 19A: the adjustment knob has detents every 1/4 turn. Rotate the knob clockwise (see Fig. 19A), to increase the depth of drive, rotate the knob counterclockwise to decrease the depth of drive. Test fire another fastener and check depth. Repeat as necessary to achieve desired results. The amount of air pressure required will vary depending on the size of the fastener and the material being fastened. Experiment with the air pressure setting to determine the lowest setting that will consistently perform the job at hand. Air pressure in excess of that required can cause premature wear and/or damage to the tool.

11

Image 11
Contents Instruction Cordless Brad Manual Nailer General Safety Rules 901891 08-31-01.qxd 2/13/02 1151 AM 901891 08-31-01.qxd 2/13/02 1152 AM Tool USE and Care Electrical SafetyPersonal Safety Work AreaSafety Instructions for Charger and Batteries ServiceSpecific Safety Rules and Symbols Do not incinerate battery pack. It can explode in a fire Foreword Power SourceEMPLOYER’S Responsibilities Functional DescriptionPreparing the Tool Operation Using the ToolLED Status Diagnostic Conition Action Nose Cushion Clearing a Jammed FastenerNormal Charging Battery OperationCharging the Battery Pack General Installing or Removing Battery Pack DiagnosticsMaintenance Symptom Problems Solutions TroubleshootingAccessories 901891 08-31-01.qxd 2/13/02 1153 AM Canadian PORTER-CABLE Delta Service Centers