Bryant 123A manual Electrical Data, Charging Subcooling TXV-TYPE Expansion Device

Page 7

ELECTRICAL DATA

UNIT SIZE

 

OPER

 

 

 

 

MIN

MIN

MAX

MAX

MAX

 

COMPR

 

FAN

 

WIRE

WIRE

LENGTH

LENGTH

FUSE**

 

VOLTS*

 

 

--- SERIES

V/PH

 

 

 

MCA

SIZE{

SIZE{

ft (m)}

ft (m)}

or CKT

 

 

 

 

 

(VOLTAGE)

 

 

 

 

 

 

 

 

 

 

 

BRK

 

MAX

MIN.

LRA

RLA

FLA

 

60° C

75° C

60° C

75° C

 

 

 

AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

018---C (N)

 

 

 

48.0

9.0

0.5

11.7

14

14

67 (20.4)

64 (19.5)

15

 

 

 

 

 

 

 

 

 

 

 

 

 

024---C (N)

 

 

 

58.3

13.5

0.75

17.6

14

14

45 (13.7)

43 (13.1)

25

030---C (N)

 

 

 

64.0

12.8

0.75

16.8

14

14

47 (14.3)

45 (13.7)

25

036---C (N)

208---230---1

253

197

77.0

14.1

1.4

19.0

12

12

66 (20.1)

63 (19.2)

30

042---C (N)

 

 

 

112.0

17.9

1.2

23.6

12

12

53 (16.2)

51 (15.5)

40

 

 

 

 

 

 

 

 

 

 

 

 

 

048---C (N)

 

 

 

109.0

19.9

1.2

26.2

10

10

76 (23.2)

73 (22.3)

40

 

 

 

 

 

 

 

 

 

 

 

 

 

060---C (N)

 

 

 

134.0

26.4

1.2

34.2

8

8

91 (27.7)

86 (262)

50

030---C (P)

 

 

 

58.0

10.1

0.75

13.4

14

14

68 (20.7)

65 (19.8)

20

036---C (P)

 

 

 

71.0

9.2

1.4

12.9

14

14

70 (21.3)

67 (20.4)

20

042---C (P)

208/230---3

253

197

88.0

13.5

1.2

18.1

12

12

80 (24.4)

76 (23.2)

30

 

 

 

 

 

 

 

 

 

 

 

 

 

048---C (P)

 

 

 

83.1

13.6

1.2

18.2

12

12

79 (24.1)

76 (23.2)

30

 

 

 

 

 

 

 

 

 

 

 

 

 

060---C (P)

 

 

 

110.0

17.7

1.2

23.3

12

12

62 (18.9)

59 (18.0)

40

036---C (E)

 

 

 

38.0

5.6

0.7

7.8

14

14

233 (71.0)

222 (67.7)

15

042---C (E)

460---3

506

414

44.0

6.0

0.53

8.0

14

14

227 (69.2)

216 (65.8)

15

048---C (E)

41.0

6.1

0.6

8.2

14

14

222 (67.7)

211 (64.3)

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060---C (E)

 

 

 

52.0

7.8

0.6

10.3

14

14

177 (54.0)

168 (51.2)

15

* Permissible limits of the voltage range at which the unit will operate satisfactorily

{If wire is applied at ambient greater than 30° C (86° F), consult table 310---16 of the NEC (ANSI/NFPA 70). The ampacity of non ---metallic---sheathed cable (NM), trade name ROMEX, shall be that of 60° C (140° F) conditions, per the NEC (ANSI/NFPA 70) Article 336---26. If other than uncoated (no---plated), 60_

or 75° C (140_ or 167° C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).

}Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time---Delay fuse.

FLA --- Full Load Amps LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- Rated Load Amps

NOTE: Control circuit is 24---V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.

Complies with 2001 requirements of ASHRAE Standards 90.1

A-WEIGHTED SOUND POWER (dBA)

 

STANDARD

 

TYPICAL OCTAVE BAND SPECTRUM (dBA, without tone adjustment)

UNIT SIZE --- SERIES

RATING

 

 

 

 

 

 

 

 

 

(dBA)

125

 

250

500

1000

2000

4000

8000

 

 

 

 

 

 

 

 

 

 

018---C

74

50.0

 

61.5

64.5

66.5

64.0

61.0

54.5

 

 

 

 

 

 

 

 

 

 

024---C

75

55.5

 

63.5

67.0

70.0

66.0

63.5

57.0

 

 

 

 

 

 

 

 

 

 

030---C

74

52.5

 

63.0

68.5

70.0

66.5

62.5

56.5

 

 

 

 

 

 

 

 

 

 

036---C

75

57.0

 

65.0

67.5

69.5

67.5

65.0

60.0

 

 

 

 

 

 

 

 

 

 

042---C

74

55.0

 

64.0

68.0

68.5

64.5

60.0

54.0

 

 

 

 

 

 

 

 

 

 

048---C

74

52.5

 

62.5

65.5

69.0

63.5

60.5

56.0

 

 

 

 

 

 

 

 

 

 

060---C

74

54.0

 

59.0

65.5

67.5

63.5

60.0

55.5

 

 

 

 

 

 

 

 

 

 

NOTE: Tested in accordance with AHRI Standard 270---95 (not listed in AHRI).

CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE)

UNIT SIZE---SERIES

REQUIRED SUBCOOLING _F (_C)

018---C

8 (4.4)

024---C

13 (7.2)

030---C

16 (8.9)

036---C

16 (8.9)

042---C

10 (5.6)

048---C

17 (9.4)

060---C

11 (6.1)

123A

7

Image 7
Contents Product Data Model Number Nomenclature Standard FeaturesVapor Line Sizing and Cooling Capacity Loss Physical Data030---C AccessoriesAccessory Thermostats Unit SIZE---SERIES VoltageYes Accessory Usage GuidelineOutdoor Air Temperature Sensor Charging Subcooling TXV-TYPE Expansion Device Electrical DataDimensions English Dimensions SI Clearances Capacity PhaseCombination Ratings Ahri Ref. No Model Number Indoor Model Furnace ModelFF1ENP030 FF1ENP036 3046713 123APA030---C 34400 34000 33800 33600 33200 34200 33400 34600 35000 FE4ANB006+UI 3046776 123APA036---C 3046854 123AEA036---C 41000 41500 40000 40500 42000 42500 FY4ANF048 3046929 123APA042---C 3047004 123AEA042---C FY4ANB060 3047089 123APA048---C FV4BNB,F005 3047090 3047165 123AEA048---C FV4BNB,F005 3047166 3046032 123ANA060---C 3047239 123AEA060---C 123ANA018 Detailed Cooling CAPACITIES#900 123ANA024700 8001125 123ANA030875 10001350 123ANA0361050 12001575 123ANA0421225 14001600 123ANA0481800 2250 123ANA0601750 2000Condenser only Ratings SST Condenser Entering AIR Temperatures F C123A*A042---C Products Guide Specifications GeneralCatalog No. PDS123A---04
Related manuals
Manual 6 pages 53.7 Kb

123A specifications

Bryant 123A is a high-efficiency residential air conditioning unit that stands out for its reliable performance and advanced features. Designed with homeowners in mind, this model combines modern technology with user-friendly functionality, ensuring optimal comfort in various climates.

One of the main features of the Bryant 123A is its variable-speed compressor, which allows for precise temperature control and energy savings. Unlike traditional units that operate at a fixed speed, the variable-speed compressor adjusts its output based on the cooling needs of the home. This not only maintains a more consistent indoor temperature but also reduces energy consumption, making it an environmentally friendly choice.

The unit also boasts a SEER (Seasonal Energy Efficiency Ratio) rating of up to 19. This high rating means that the Bryant 123A operates with exceptional energy efficiency, translating into lower utility bills. Homeowners will appreciate the long-term savings that come with this energy-efficient design.

In addition to its impressive efficiency, the Bryant 123A features a robust construction designed to withstand various weather conditions. The steel cabinet is both durable and corrosion-resistant, ensuring that the unit will endure over time. Furthermore, the unit is equipped with a sound-dampening system that minimizes operational noise, providing a quieter indoor environment.

Smart technology integration is another significant characteristic of the Bryant 123A. Homeowners can benefit from the optional Ecobee Smart Thermostat compatibility, allowing remote access and control of the cooling system through smartphone apps. This feature enables users to adjust settings from anywhere, enhancing convenience and energy management.

Moreover, the Bryant 123A utilizes eco-friendly refrigerant, further solidifying its commitment to sustainable practices. The R-410A refrigerant is not only effective at cooling but also contributes to lower ozone depletion potential. This choice aligns with modern environmental standards and regulations, making the unit a responsible choice for conscious consumers.

Overall, the Bryant 123A unit is a standout option for residential air conditioning, offering advanced features, high efficiency, and durable construction. Whether for new installations or replacements, this model promises to deliver reliable cooling performance while maximizing cost savings and environmental responsibility. Homeowners seeking comfort without compromise will find the Bryant 123A an ideal solution for their cooling needs.