Grizzly G1052 Circuit Requirements, 110V Operation, Fusing, Grounding, Extension Cords

Page 7

SECTION 2: CIRCUIT REQUIREMENTS

110V Operation

The Model G1052 has a 1/2 HP motor which oper- ates at 110V. It includes a complete cordset with a grounded plug that’s made for use with a grounded domestic 110V outlet.

The G1052 motor will safely draw about 8 amps at 110V under load. If you operate the bandsaw on any circuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if an unusual load does not exist, and power failure still occurs, have the circuit inspect- ed by a qualified electrician.

Fusing

The Model G1052 should be fused at 15 amps. Fusing at amperage ratings higher than 15 amps will not adequately protect the motor. You are cautioned that equipment that is returned to us for service that shows evidence of being over- fused will be repaired or replaced totally at the customer’s expense, regardless of the present warranty status.

Grounding

Figure 1. Recommended outlet/plug configuration.

This equipment must be grounded, there is a risk of severe electrical shock. Verify that any existing electrical outlet and circuit you intend to plug into is actually grounded. If it is not, it will be necessary to run a separate 14 A.W.G. copper grounding wire from the outlet to a known ground. Consult a qualified electri- cian if you are uncertain of the grounding of your electrical system. Under no circum- stances should the grounding pin from any three-pronged plug be removed. Serious injury may occur.

Extension Cords

In the event of an electrical short, grounding reduces the risk of electric shock by providing a path of least resistance to disperse electric cur- rent. This tool is equipped with a power cord which has an equipment grounding conductor. The outlet must be properly installed and ground- ed in accordance with local codes. Refer to Figure 1 for the proper outlet and plug configura- tion.

If you find it necessary to use an extension cord with the Model G1052, make sure the cord is rated Hard Service (grade S) or better. Refer to the chart in the standard safety instructions to determine the minimum gauge for the extension cord. The extension cord must also contain a ground wire and plug pin. Always repair or replace extension cords when they become worn or damaged.

 

 

 

 

 

 

 

 

 

 

 

 

G1052 9" Bandsaw

-5-

Image 7
Contents Bandsaw Page Table Of Contents Safety Instructions For Power Tools SafetyAMP Rating Additional Safety Instructions For Bandsaws Grounding FusingCircuit Requirements 110V OperationCommentary IntroductionParts Inventory UnpackingSite Considerations Clean UpBandsaw Unit AssemblyBlade Adjustments AdjustmentsTension Co-Planarity Blade guide assemblies G1052 9 Bandsaw Tracking Blade GuidesGuide Bearing Shaft Blade Support Bearing Space Each Side Squaring the blade to the table G1052 9 Bandsaw Table AdjustmentsTo replace the blade Changing BladesGuide Post Overview OperationsTest Run Blade Information Ripping Cutting Curves Crosscutting Stacked CutsGeneralTable MaintenanceLubrication Closure Machine Data Sheet Parts Diagrams Bearing Guides Table and Fence 100 101 102 104 103 8393 106 105 REF# PART# Description Parts ListsFlat Washer #10 Symptom Possible Cause Corrective Action TroubleshootingWarranty and Returns Warranty Card Grizzly INDUSTRIAL, INC