Grizzly G8298, G8299, G8297 instruction manual Pressure Limit Adjustment

Page 16

Pressure Limit

Adjustment

The compressor is delivered with pressure switch settings which turn the compressor pump off when it reaches a tank pressure of 135 PSI, and turn it back on when it reaches 105 PSI. Normally these settings should not require any adjustment.

In the event it becomes necessary to change, first make certain the compressor is disconnected from the power source. Then remove the black plastic cover below the On/Off switch. This is done by removing the rubber plug on top of the housing and inserting a Phillips® screwdriver. See

Figure 10.

The hex nut on the top of the exposed switch is used to adjust the pressure limits. See Figure 11. Turn it clockwise to increase the pressure and counterclockwise to reduce. This will move both the maximum pressure shutoff point and the min- imum pressure turn-on point simultaneously. These limits are not separately adjustable. Do not exceed a maximum cutoff pressure of 145 PSI.

After adjusting, replace the cover and reconnect to the power source.

Adjusting Nut

Fig 10. Removing pressure switch cover.

Fig 11. Adjusting nut on pressure switch.

For the G8299, it is possible to control which motor comes on first by adjusting these pressure limits. The machine is set from the factory so the 2 HP pump comes on first to minimize amperage draw. If this is not acceptable, adjust the limits on the 2 HP higher, and set the limits on the 2.5 HP lower so they will operate in reverse of the facto- ry setting.

Do not remove the pressure switch cover with the machine plugged in to power. When the cover is off, the electrical con- nections are uncovered and can be a source of electrical shock. Make the adjust- ments progressively until the desired level is reached, and disconnect from power each time you turn the adjusting nut. Serious personal injury can occur.

 

 

 

 

 

 

 

 

 

 

 

 

-14-

G8297/G8298/G8299 Air Compressors

Image 16
Contents Contractor Grade AIR Compressors Model G8297/G8298/G8299Page Table Of Contents Safety Safety Instructions For Power ToolsLength AMP Rating 11-12 13-16 17-20 21-30Additional Safety Instructions For Air Compressors Circuit Requirements 110V OperationExtension Cords GroundingIntroduction CommentaryUnpacking Oil sump and dipstick Pressure safety relief valve Thermal protection typical placementOperations GeneralStarting Pressure Regulator G8299 starting switches and gaugePressure regulator and gauge Connecting Tools CFMMaintenance Each UseChecking oil level with dipstick Typical location of drain cocksAfter First 50 Hours WeeklyEvery 300 Hours Air filter cover and foam elementPressure Limit Adjustment Closure Parts List G8297 AIR Compressor G8297/G8298/G8299 Air Compressors Parts List G8298 AIR Compressor G8297/G8298/G8299 Air Compressors Parts List G8299 AIR Compressor Troubleshooting Symptom Possible Cause Corrective ActionWarranty and Returns Warranty Card Grizzly INDUSTRIAL, INC Send a Grizzly Catalog to a friend Name Street CityStateZip