Harbor Freight Tools 68023 User-Instructions, Clearing Jams, User-Maintenance Instructions

Page 13

USER-INSTRUCTIONS

User-Maintenance Instructions

Procedures not specifically explained in this manual must be performed only by a qualified technician.

TO PREVENT SERIOUS INJURY

FROM ACCIDENTAL OPERATION, BEFORE ANY MAINTENANCE OR REPAIRS ARE DONE (including clearing jams):

Wear ANSI-approved safety goggles with side shields. Other people in the work area must also wear ANSI-approved impact safety goggles with side shields.

Release the Trigger.

Detach the air supply.

Attempt to fire the Tool into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any fasteners.

Empty the magazine and leave Pusher pulled back during service. The Pusher is spring- loaded and may cause parts or a fastener to fly out of the Tool.

TO PREVENT SERIOUS INJURY FROM TOOL FAILURE: Do not use damaged equipment. If abnormal noise, vibration, or leaking air is detected, correct problem before further use.

TO PREVENT EXPLOSION:

Lubricate only with specified lubricants. Lubricate the air inlet using only pneumatic tool oil. Lubricate the internal mechanism using only white lithium grease. Other lubricants may damage the mechanism and may be highly flammable, causing an explosion.

Note: These procedures are in addition to the regular checks and maintenance explained as part of the regular operation of the air-operated tool.

Daily - Air Supply Maintenance: Every day, perform maintenance on the air supply according to the component manufacturers’ instructions. The lubricator’s oil level needs to be maintained and the moisture filter must be regularly drained. Performing routine maintenance on the air supply will allow the tool to operate more safely and will also reduce wear on the tool.

Clearing Jams

TO PREVENT SERIOUS INJURY

FROM ACCIDENTAL OPERATION, BEFORE ANY MAINTENANCE OR REPAIRS ARE DONE (including clearing jams):

Wear ANSI-approved safety goggles with side shields. Other people in the work area must also wear ANSI-approved impact safety goggles with side shields.

Release the Trigger.

Detach the air supply.

Attempt to fire the Tool into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any fasteners.

Empty the magazine and leave Pusher pulled back during service. The Pusher is spring- loaded and may cause parts or a fastener to fly out of the Tool.

1.Disconnect tool from air hose, pull the Pusher back, empty Magazine of fasteners, release any built-up air pressure, and leave Pusher pulled back.

SKU 68023

For technical questions, please call 1-800-444-3353.

Page 13

Image 13
Contents Gauge AIR Finish Nailer Symbol Property or statement Safety Alert Symbol and Signal WordsSave this Manual For technical questions, please callGeneral Personal safetyWork area Tool use and care ServiceAir source Save These Instructions Vibration Precautions Functional Description SpecificationsUnpacking Components and ControlsSKU A EAir Tool Spray Gun Stationary SKU 68023 For technicalQuestions, please call Injury from Accidental Operation Full Sequential Safety Trip Mechanism Definition Work Piece and Work Area Set UpFull Sequential Safety Trip Mechanism Testing Procedure Operating InstructionsGeneral Operating Instructions Loading the ToolDo not exceed 120 Max. PSI USER-INSTRUCTIONS User-Maintenance InstructionsClearing Jams To Prevent Serious InjuryFor technical questions, please call Problem Possible Causes Likely Solutions TroubleshootingPart Description Parts ListQty Part Description Qty For technical questions, please call444-3353 Assembly DiagramLimited 1-Year Warranty