APPENDIX: 12.4 WIRING DIAGRAMS

12.4.4 Legend .. 5CS to .. 17CS

A1

Wire jumper, must be removed if a utility company disable contactor is used

A2

Wire jumper, must be removed if 2nd disable input is used

 

A3

Wire jumper, must be removed if a motor protection contact for primary pump is used

A4

Wire jumper, must be removed if a motor protection contact for the compressor is used

 

Open wire jumpers or contacts mean: lock-out or malfunction

B2*

Pressostat low pressure, brine

 

B3*

Thermostat, hot water

 

B4*

Thermostat, swimming pool water

 

E9*

Electr. immersion heater, hot water

 

E10*

Suppl. heating system (boiler or electr. heating element)

 

F2

Load fuse for N1 relay outputs across J12 and J13

4.0 A slow

F3

Load fuse for N1 relay outputs across J15 to J18

4.0 A slow

F4

Pressostat high pressure

 

F5

Pressostat low pressure (in SI 17CS, F5 is a limiter with manual reset)

F15*

Motor protection M11, from SI 9CS to SI 17CS integrated in primary pump

H5*

Lamp, remote fault indicator

 

J1...J18

Terminal connector at N1

 

K1

Contactor, compressor

 

K5

Contactor, primary pump

 

K11*

Electron. relay for remote fault indicator (relay module)

 

K12*

Electron. relay for swimming pool water circulating pump

 

K20*

Contactor, suppl. heating system

 

K21*

Contactor, electr. immersion heater, hot water

 

K22*

Utility company disable contactor

 

K23*

SPR auxiliary contactor

 

M1

Compressor

 

M11*

Primary pump

 

M13*

Heating circulating pump

 

M15*

Heating circulating pump for heating circuit 2

 

M16*

Suppl. circulating pump

 

M18*

Hot water circulating pump

 

M19*

Swimming pool circulating pump

 

M21*

Mixer heating circuit 1

 

M22*

Mixer heating circuit 2

 

N1

Heat pump controller

 

N7

Soft start control (not fitted in SI 5CS and SI 7CS appliances)

N10*

Remote control station

 

N11*

Relay module

 

R1

External sensor

 

R2

Return sensor

 

R3

Hot water sensor (as an alternative to hot water thermostat)

 

R5

Sensor for heating circuit 2

 

R6

Freeze protection sensor

 

R7

Coding resistor 8k

 

T1

Safety isolating transformer 230/24V AC-28V A

 

X1

Terminal strip mains control L/N/PE-230V AC-50 Hz/fuses/N and PE-terminal block

X2

Terminal strip 24V AC-terminal block

 

X3

Terminal strip GND terminal block for sensors R1/-2 and -3 at J2

X4

Terminal stripGND terminal blocl for sensors R5 and -6 at J6

 

X5

Terminal strip power supply 3 L/PE-400V AC-50 Hz

 

Abbreviations:

 

 

EVS

Utility company disable input

 

SPR

Supplementary disable input

 

MA*

Mixer OPEN

 

MZ

Mixer CLOSED

 

*Components to be supplied by the customer

32

Image 32
Contents Operating Manual Purpose of the Heat Pump Read Immediately Important InformationLegal Provisions and Directives Energy-Efficient Use of the Heat PumpPurpose of the Heat Pump Baseline UnitApplication Principle of OperationBrine Manifold AccessoriesTransport Installation MountingConnection on Heat Source Side Electrical ConnectionPreparation Commissioning ProcedureCommissioning CARE/CLEANING Cleaning of Heating SideCleaning of Heat Source Side CareMalfunctions DecommissioningShutdown in Summer End-of-Life Decommissioning/ DisposalAppendix Dimensioned Drawing . CS 14CS Dimensioned Drawings . CS 21 CS Equipment Data PerformancedataPerformance Curves . CS ConditionsPressure Losses . CS Bei Sole -5C10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 PressureDruckv rlustloss 10 kPa beiat a Heating capacity in kW Water outlet temperature in C Pressure Losses . CS 24,0 22,0 20,0 18,0 16,0 14,0 12,0 10,0 Loss 13 kPa at a Water outlet temperature in C 14000 12000 SoleBrineintriinlettstemperaturtemperature ininC 24000 Performance Curves . CS Druckverlu te Verdampfer VVJ3 Ininvorhanden7C5C7C Load . CS to . CSErdi1 EVS VJV PX5 MV2 Appendix 12.4 Wiring Diagrams Hydraulic Block Diagram Declaration of Conformity EC Declaration of Conformity

SI 11CS, SI 14CS, SI 5CS, SI 9CS, SI 21CS specifications

Dimplex, a renowned name in electric heating solutions, offers a range of innovative and efficient storage heaters designed to provide optimal heating performance. The Dimplex SI series includes models SI 5CS, SI 7CS, SI 9CS, SI 17CS, and SI 21CS, each tailored to meet diverse heating needs in residential settings. These heaters embody advanced technology, featuring a blend of user-centric design and energy-efficient operation.

One of the standout features of the Dimplex SI series is its ability to store heat generated during off-peak electricity hours and release it gradually throughout the day. This ensures comfortable living environments while taking advantage of lower energy rates. The high-density ceramic core used in these models retains warmth effectively, allowing for consistent heat output, making them ideal for homes with varying occupancy schedules.

The SI series is designed with user convenience in mind. Each model incorporates a built-in thermostat, enabling users to easily set and maintain their desired temperature. Furthermore, the added convenience of a digital display on select models allows for straightforward monitoring of energy consumption and temperature settings.

Dimplex’s innovative Dimplex Boost technology available in these heaters ensures that extra warmth can be introduced rapidly when needed, catering to sudden drops in temperature or unexpected gatherings. This feature is especially beneficial for homes in cooler climates where adaptability is crucial.

For ease of installation, the SI series models are lightweight and compact, allowing them to fit seamlessly in various spaces, from small apartments to larger homes. Ample safety features, such as thermal cut-out and overheat protection, provide peace of mind for users.

In terms of efficiency, these storage heaters are designed to meet high energy efficiency standards, minimizing operational costs while maximizing comfort. With various power outputs available across the series, customers can select the model that best fits their specific heating requirements.

Overall, the Dimplex SI 5CS, SI 7CS, SI 9CS, SI 17CS, and SI 21CS represent the brand’s commitment to quality, efficiency, and user-friendly heating solutions, offering modern technologies to enhance everyday living. These storage heaters redefine electric heating and stand as excellent additions to any home looking to optimize energy use and comfort.