Dimplex SI 14CS, SI 9CS, SI 17CS, SI 7CS, SI 5CS Malfunctions, Decommissioning, Shutdown in Summer

Page 10

MALFUNCTIONS/TROUBLESHOOTING DECOMMISSIONING

MALFUNCTIONS/

10 TROUBLESHOOTING 11

This heat pump is a quality product and is designed for trouble-free operation. In the event that a malfunction occurs nevertheless, you will be able to correct the problem yourself in most of the cases. Simply consult the Malfunctions and Trouble- shooting table contained in the operating manual of the heat pump controller.

Additional malfunctions can be interrogated at the heat pump controller.

If you cannot correct the malfunction yourself, please contact the after-sales service agent in charge (see Warranty Certificate).

CAUTION! All work on the heat pump may only be performed by an authorised and qualified after-sales service.

CAUTION! All electrical circuits must be dis- connected from the power source prior to opening the equipment.

DECOMMISSIONING

11.1 Shutdown in Summer

Shutting down the heating system in summer is effected by switching the heat pump controller to the "Summer" operating mode.

11.2End-of-Life Decommissioning/ Disposal

Before removing the heat pump, disconnect the machine from the power source and close all valves. Environment-relevant requirements regarding the recovery, recycling and disposal of service fuels and components in accordance with all relevant standards must be adhered to. Particular attention must hereby be paid to the proper disposal of refrigerants and refrigeration oils.

10

Image 10
Contents Operating Manual Purpose of the Heat Pump Legal Provisions and Directives Read ImmediatelyImportant Information Energy-Efficient Use of the Heat PumpApplication Purpose of the Heat PumpBaseline Unit Principle of OperationTransport AccessoriesBrine Manifold Installation MountingConnection on Heat Source Side Electrical ConnectionCommissioning Commissioning ProcedurePreparation Cleaning of Heat Source Side CARE/CLEANINGCleaning of Heating Side CareShutdown in Summer MalfunctionsDecommissioning End-of-Life Decommissioning/ DisposalAppendix Dimensioned Drawing . CS 14CS Dimensioned Drawings . CS 21 CS Equipment Data PerformancedataPerformance Curves . CS ConditionsPressure Losses . CS Bei Sole -5C10 -8 -6 -4 -2 0 2 4 6 8 10 12 14 16 18 20 22 24 PressureDruckv rlustloss 10 kPa beiat a Heating capacity in kW Water outlet temperature in C Pressure Losses . CS 24,0 22,0 20,0 18,0 16,0 14,0 12,0 10,0 Loss 13 kPa at a Water outlet temperature in C 14000 12000 SoleBrineintriinlettstemperaturtemperature ininC 24000 Performance Curves . CS Druckverlu te Verdampfer VVJ3 Ininvorhanden7C5C7C Load . CS to . CSErdi1 EVS VJV PX5 MV2 Appendix 12.4 Wiring Diagrams Hydraulic Block Diagram Declaration of Conformity EC Declaration of Conformity

SI 11CS, SI 14CS, SI 5CS, SI 9CS, SI 21CS specifications

Dimplex, a renowned name in electric heating solutions, offers a range of innovative and efficient storage heaters designed to provide optimal heating performance. The Dimplex SI series includes models SI 5CS, SI 7CS, SI 9CS, SI 17CS, and SI 21CS, each tailored to meet diverse heating needs in residential settings. These heaters embody advanced technology, featuring a blend of user-centric design and energy-efficient operation.

One of the standout features of the Dimplex SI series is its ability to store heat generated during off-peak electricity hours and release it gradually throughout the day. This ensures comfortable living environments while taking advantage of lower energy rates. The high-density ceramic core used in these models retains warmth effectively, allowing for consistent heat output, making them ideal for homes with varying occupancy schedules.

The SI series is designed with user convenience in mind. Each model incorporates a built-in thermostat, enabling users to easily set and maintain their desired temperature. Furthermore, the added convenience of a digital display on select models allows for straightforward monitoring of energy consumption and temperature settings.

Dimplex’s innovative Dimplex Boost technology available in these heaters ensures that extra warmth can be introduced rapidly when needed, catering to sudden drops in temperature or unexpected gatherings. This feature is especially beneficial for homes in cooler climates where adaptability is crucial.

For ease of installation, the SI series models are lightweight and compact, allowing them to fit seamlessly in various spaces, from small apartments to larger homes. Ample safety features, such as thermal cut-out and overheat protection, provide peace of mind for users.

In terms of efficiency, these storage heaters are designed to meet high energy efficiency standards, minimizing operational costs while maximizing comfort. With various power outputs available across the series, customers can select the model that best fits their specific heating requirements.

Overall, the Dimplex SI 5CS, SI 7CS, SI 9CS, SI 17CS, and SI 21CS represent the brand’s commitment to quality, efficiency, and user-friendly heating solutions, offering modern technologies to enhance everyday living. These storage heaters redefine electric heating and stand as excellent additions to any home looking to optimize energy use and comfort.